Page 71
Operating Instructions
Operation
Chapter 6
CLV 41x bar code scanner
6.5.2
Percentage evaluation
In the Percentage evaluation mode, the reading quality of bar codes which enter the reading field of the CLV and are not moved (conveyor off) is assessed. This mode allows to check the correct alignment of the CLV to the bar code. The CLV performs 100 scans in "Free Running" mode and evaluates the reading quality. It outputs the reading result continuously every 2 s together with a fixed set of reading diagnosis data. The reading results can be displayed in the terminal emulator of CLV Setup. The switching outputs "Result 1" to "Result 3" and the beeper do not become live in the Percentage evaluation mode. The Percentage evaluation mode can be called up by choosing VIEW in the menu bar or via the terminal emulator. 1.
Click in the toolbar. The terminal emulator window is then displayed. The CLV is in reading mode.
2.
Click PERCENT EVALUATION under DEVICE MODE. The "Device Ready" LED is extinguished. The CLV initiates the percentage evaluation and outputs the reading results continuously. An example is shown in Fig. 6-3.
3.
Present the bar code pattern from Fig. 6-1, Page 6-3 and monitor the reading results in the terminal emulator window.
The behavior of the "Result" LED also indicates the reading quality: –
LED is extinguished if reading quality is < 30 %
–
LED flashes twice per second if the reading quality is 30 % to 70 %
–
LED flashes five times per second if the reading quality is 70 % to 90 %
–
LED is lit continuously if the reading quality is > 90 %
Fig. 6-3:
CLV Setup: Percentage evaluation mode: output of the reading result in the terminal emulator
Fig. 6-4, Page 6-18 explains the structure and function of the reading diagnosis data for Good Read, and Fig. 6-5, Page 6-18 for No Read.
8 009 974/O079/01-09-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-17
Page 72
Operation
Chapter 6
Operating Instructions CLV 41x bar code scanner
Successful read (good read): TT =__200 ms MG =_17% n =_1 UVWXYZ C39 _94% ST = 0 CP =_47 CL = _6 CA =100 CS = _94 CK=_54 with: 1st line: TT MG n 2nd line: UVWXYZ 3rd line: C39 _94% ST CP CL CA CS CK Fig. 6-4:
= = = = = = = = = = = =
Reading interval time Long-term mean value of identification quality Number of recognized codelabels Data content of the bar code ID: Code 39 Identification quality Read status (ST = 0, Good read) Code position Code length (character count) Scanning expenditure Code security Code continuity
Percentage evaluation mode: structure of the reading result for "good read"
No read: TT =__200 ms MG =__18% n =_0 no code!
with: 1st line: TT MG n 2nd line: no code! Fig. 6-5:
Note
= Reading interval time = Long-term mean value of identification quality = Number of recognized codelabels = No bar codes found!
Percentage evaluation mode: structure of the reading result for "no read"
Profile bar codes read by the CLV during the percentage evaluation do not cause any changes to be made to the parameter set and do not, therefore, affect the reading process either. The match code cannot be programmed (taught in) in the percentage evaluation mode. This is entered on the DEVICE CONFIGURATION tab. The match code 1 can also be programmed using the teach-in method. The CLV outputs the data contents of the uncovered polling reflector with the identifier "REPO" in the percentage evaluation mode.
6-18
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 974/O079/01-09-2004
Page 73
Operating Instructions
Operation
Chapter 6
CLV 41x bar code scanner
6.5.3
Read Rate Evaluation
This operating mode complies with the Percentage Evaluation mode (see Chapter 6.5.2 Percentage evaluation, Page 6-17). In destinction from the Percentage Evaluation the CLV does not output any reading results via the host interfaces. It signals the current reading rate with the behaviour of the "Result" LED (flashing frequency) and additionally with a corresponding tone sequence of the beeper (Table 6-6). Reading rate
LED flashing frequency
Tone sequence
< 30 % off
1 Hz
30 to 70 %
2 Hz
2 Hz
70 to 90 %
5 Hz
5 Hz
90 % to 100 % on continuous tone
Table 6-6: Read Rate Evaluation: Tone sequence of the beeper as a function of the reading rate
The "Device Ready" LED and the switching outputs "Result 1" to "Result 3" do not become live in Read Rate Evaluation. The Read Rate Evaluation can be called up via the terminal emulator as followed: 1.
Click in the toolbar. The terminal emulator window is then displayed. The CLV is in reading mode.
2.
Enter 17 in the command line ➀ and press the [Return] key (Fig. 6-6). The "Device Ready" LED is extinguished. The CLV initiates the Read Rate Evaluation and indicates the reading quality results continuously by signals of the beeper.
3.
Present the bar code pattern from Fig. 6-1, Page 6-3 and listen to the tone sequence of the beeper. A continuous tone signals the optimum of reading rate and the correct alignment of the CLV to the bar code.
4.
Enter 11 in the command line to return to Reading mode and press the [Return] key.
5.
Close the terminal emulator.
➀
Fig. 6-6:
8 009 974/O079/01-09-2004
CLV Setup: Calling up the “Read Rate Evaluation“ mode in the terminal emulator
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-19
Page 74
Chapter 6
Operation
Operating Instructions CLV 41x bar code scanner
6.5.4
Displaying and editing operating data
This function enables statistical operating data, which the CLV maintains in the form of counters during the reading procedure, to be displayed and reset. The CLV does not output a reading result in this mode. 1.
Click in the toolbar. The CLV cancels reading mode. The "Device Ready" LED is extinguished. The OPERATING DATA dialog box appears (Fig. 6-7).
2.
After checking/resetting the desired counters, click "OK" to confirm any changes made. The CLV returns to reading mode. The "Device Ready" LED lights up.
Fig. 6-7:
6.5.5
CLV Setup: "Operating Data" dialog box
Self-test
After the CLV has been switched on, it performs a self-test before it is initialized with the parameter set. The test can be called up explicitly at any time via CLV Setup. During the selftest, the CLV checks that its hardware components are functioning correctly. A final message provides information on the test result. The CLV does not output a reading result during the test routine.
6-20
1.
Click in the toolbar. The terminal emulator window is then displayed. The CLV is in reading mode.
2.
Click SELF TEST under DEVICE MODE. The "Device Ready" LED is extinguished. The CLV cancels the reading mode and starts the test routine. After a few seconds, the CLV outputs the encoded test result in the form of a code number (Fig. 6-8).
3.
To return to the reading mode, activate READING MODE or close the terminal emulator. The CLV returns to reading mode. The "Device Ready" LED lights up.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 974/O079/01-09-2004
Page 75
Operating Instructions
Operation
Chapter 6
CLV 41x bar code scanner
Fig. 6-8:
CLV Setup: displaying the self-test result in the terminal emulator
The code number "15000" means that the self-test was completed successfully and that no faults were diagnosed. 6.5.6
Performing device functions of the CLV in the dialog box
CLV Setup enables a number of CLV functions to be executed interactively. CLV Setup prompts the user to carry out specific actions and provides information on the progress of the function being executed. The following functions are available: •
AutoSetup
•
Match code Teach-in
•
Activate factory defaults in device
¾
In the menu bar, select the desired function from CLV 41X, DEVICE FUNCTIONS. – or – Press the [F2] key. The DEVICE FUNCTIONS dialog box is then displayed. Select the desired function from the EXECUTE menu. CLV Setup starts the function and, where appropriate, prompts the user to carry out the necessary action.
Fig. 6-9, Page 6-22 shows an example of the dialog box that appears after AutoSetup has been started.
8 009 974/O079/01-09-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
6-21
Page 76
Chapter 6
Operation
Operating Instructions CLV 41x bar code scanner
Fig. 6-9:
6.6
CLV Setup: dialog box for AutoSetup execution
CLV messages
The CLV outputs coded error messages (3 digits, 15xxx) only in the Self-test mode. In Reading mode the CLV outputs the ST reading error status in the "Separator" block of the reading result (if the error status has been enabled via the DATA STRINGS tab. Disabled in default setting). ST= 3 indicates a device fault. For further values of the ST error status see Table 8-1, Page 8-2.
6.7
Switching off the CLV
1.
If the parameter set was modified in CLV Setup or was only stored temporarily in CLV 41x via a download ("Temporary" option or via context menu (right mouse button)), the parameter set must be stored permanently in the CLV 41x by choosing the PERMANENT storage option.
2.
Save parameter set as a "*.scl" configuration file in CLV Setup.
3.
Switch off the power supply of the CDB 410 or CDM 410 or pull the plug of the CLV from the connection module.
The last parameter set stored permanently in the CLV remains valid. We recommend that you print out the configuration file in order to archive the parameter set.
6-22
1.
Click in the toolbar. The PRINT FILE dialog box is then displayed.
2.
Enter a comment in the input field in order to assign the printout to the CLV. Confirm the dialog box with "OK". The PRINT dialog box for configuring the printer is then displayed.
3.
Edit the dialog box accordingly and confirm. CLV Setup prints out the current configuration file in the form of a table.
© SICK AG · Division Auto Ident · Germany · All rights reserved