Operating Instructions: CLV 41x Bar Code Scanner, Standard line: 5 Electrical connection

Pages 41 to 54 of 142, from Operating Instructions: CLV 41x Bar Code Scanner, Standard line

The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick CLV410, Sick CLV412 and Sick CLV414

Page 41

Operating Instructions

Electrical connection

Chapter 5

CLV 41x bar code scanner

5

Electrical connection 5.1

Overview of the connection sequence

•

Connect the CLV to the SICK CDB 410 or CDM 410 connection module

•

Connect the data and function interfaces of the CLV in the module

•

Connect the PC to the connection module (at the host interface 2 of the CLV)

•

Connect the power supply to the connection module

5.2

Electrical connections and cables

The electrical connection for the CLV consists of a 15-pin D Sub HD plug. It supplies the following interfaces: • two serial data interfaces (host interface 1 and 2)

• two switching inputs (external reading pulse and multifunctional input)

• three switching outputs (for result status functions, or connecting to a PLC for example)

• power supply

¾

Wire all the connections with copper cables with a minimum wire diameter of 0.09 mm2 (approx. 17 AWG)!

5.2.1

Connections/cables for the CDB 410 or CDM 410 connection module

The CDB 410 or CDM 410 connection module is suitable for connecting the CLV to peripherals (distribution function) and the power supply. The module can be used to establish a connection to the host (point-to-point) or to integrate the device in a SICK Network (RS 485) or daisy-chain configuration (pass-through or master/slave configuration). Fig. 5-1 shows the connection principle of the CDB 410 or CDM 410 for one CLV. CLV 41x

CDB 410 or CDM 410 connection module Photoelectric switch Reading pulse

AUX

HOST/PLC

“6 to 30 V DC“ Teach-in Match code 1

PLC 6 to 30 V DC

– – cable if necessary

Fig. 5-1:

Block diagram: connection of the CLV to the CDB 410 or CDM 410 connection module

8 009 974/O079/01-09-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-1

Page 42

Electrical connection

Chapter 5

Operating Instructions CLV 41x bar code scanner

Connect and configure the CDB 410 or CDM 410 Connection Module as described in the “CDB 410 Connection Module“ Operating Instructions (order no. 8 010 000, German/English version) respectively in the “CDM 410 Connection Module“ Operating Instructions (order no. 8 010 003, German/English version). Note

Diagramms showing you how to connect the CDB 410 and CDM 410 Connection Modules are also available in the “CLV Connect“ PC program. This software is available on the “Manuals & Software“ CD ROM, which is included in the scope of delivery of the ICR. The software can also be downloaded from the SICK home page (www.sick.de) at “Service& Support/ Downloadpool“. It can be called up using a standard HTML browser (e. g. Internet ExplorerTM).

5.3

Connector pin assignment 6 1

11

5 10

15

Pin

Signal

Function

1

5 to 30 V DC

Power supply

2

Sensor 2

Switching input Teach-in (match code)

3

Result 3

Switching output, variable function

4

Term RS 422

Termination host interface 1

5

GND

Ground

6

RD+ (RS 422/485)

Host interface 1 (receiver)

7

RD– (RS 422/485)

Host interface 1 (receiver)

8

TD+ (RS 422/485)

Host interface 1 (transmitter)

9

TD– (RS 422/485)

Host interface 1 (transmitter)

10

RxD (RS 232)

Host interface 2 (receiver)

11

TxD (RS 232)

Host interface 2 (transmitter)

12

Result 1

Switching output, variable function

13

Result 2

Switching output, variable function

14

Sensor 1

Switching input for external reading pulse

15

SensGND

Common ground for all inputs

–

–

Shield

Table 5-1: Pin assignment of the 15-pin D Sub HD plug

5-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 43

Electrical connection

Operating Instructions

Chapter 5

CLV 41x bar code scanner

5.4

Preparations for electrical connection

5.4.1

Requirements for the host interface

The host interfaces of the CLV can be operated as RS 422/485 or RS 232 interface. Table 5-2 shows the recommended maximum cable lengths as a function of the selected data transfer rate. Interface type

Transfer rate

Distance from host

RS 232 up to 19,200 bd max. 10 m (32.8.ft)

38,400 to 57,600 bd max. 3 m (9.84 ft)

max. 38,400 bd max. 1,200 m (3,937 ft)

max. 57,600 bd max. 500 m (1,640 ft)

RS 422/485

1)

1) with suitable line termination according to specification

Table 5-2: Maximum cable lengths between the CLV and host

¾ Note

To prevent interference, do not lay the cable parallel with power supply and motor cables over long distances, e.g. in cable ducts.

To meet the FCC-regulations, the cables have to shielded including connections from shielding to the connector casings. 5.4.2

Power supply

The CLV requires a power supply of 5 to 30 V DC (functional extra-low voltage) in accordance with the standard IEC 364-4-41. The functional extra-low voltage can be generated by using a safety isolating transformer pursuant to IEC 742. The CLV has a power consumption of max. 3 W (when switching outputs are not connected). The CLV is supplied with 6 to 30 V DC via the CDB 410 or CDM 410 connection module. If the CMP 400 Power Supply Module is used in the CDM 410, a mains voltage of 100 to 250 V AC/50 to 60 Hz is required. Note

The CLV 41x is UL certificated when a class 2 power supply according to UL 1310 is used. Power-up delay The selected device number (default setting: 1) affects the power-up delay of the device. This is useful if a large number of CLVs (e.g. in the SICK Network) are supplied from one power source. Table 5-3 contains a list of the available intervals. Device number GN 1; 11; 21; 31

Power-up delay 0 ms

Device number GN 6; 16; 26

Power-up delay 2,000 ms

2; 12; 22

400 ms

7; 17; 27

2,400 ms

3; 13; 23

800 ms

8; 18; 28

2,800 ms

4; 14; 24

1,200 ms

9; 19; 29

3,200 ms

5; 15; 25

1,600 ms

10; 20; 30

3,600 ms

Table 5-3: Power-up delay as a function of the device number GN

Tip

8 009 974/O079/01-09-2004

The device number can be selected on the DEVICE CONFIGURATION tab in the CLV Setup program.

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-3

Page 44

Electrical connection

Chapter 5

Operating Instructions CLV 41x bar code scanner

5.4.3

Non-SICK power pack/connections without the SICK connection module

If a non-SICK power supply unit is used instead of the CDB 410 or CDM 410, it must provide a functional extra-low voltage in accordance with the standard IEC 364-4-41 and a continuous power output of at least 4 W. The output circuit must be reliably electrically isolated from the input circuit. Do do so, use a safety isolating transformer pursuant to IEC 742. The minimum wire cross-section for the power supply (pin 1/pin 5) is 0.15 mm2 (approx. 26 AWG). ¾ Note

Use the cable no. 6 010 137 with 15-pin D Sub HD socket and open wire ends to connect the CLV. The color assignment of the wires is shown in Table 5-4, Page 5-4.

The CLV 41x is UL certificated when a class 2 power supply according to UL 1310 is used. Pin

Signal

Wiring color

1

5 to 30 V DC red

2

Sensor 2 purple

3

Result 3 yellow

4

Term RS 422 red/black

5

GND black

6

RD+ (RS 422/485)

light blue

7

RD– (RS 422/485)

blue

8

TD+ (RS 422/485)

turquoise

9

TD– (RS 422/485)

green

10

RxD (RS 232)

gray

11

TxD (RS 232)

pink

12

Result 1 brown

13

Result 2 orange

14

Sensor 1 white

15

SensGND white/black

–

Shield white/green

Table 5-4: Wiring color assignment of cable no. 6 010 137 (open end)

5.5

Making electrical connections

5.5.1

Overview of connection procedure

•

Connect the power supply

•

Connect the host interface 1 or 2

•

Connect the PC (connect the host interface 2)

•

Connect switching input "Sensor 1" and, if necessary, "Sensor 2" as well

•

Connect switching outputs "Result 1" to "Result 3"

5.5.2

5-4

Auxiliaries

•

Tools

•

Digital measuring device (current/voltage measurement)

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 45

Operating Instructions

Electrical connection

Chapter 5

CLV 41x bar code scanner

5.5.3

Connecting the power supply

If the CLV is powered via the CDB 410 or CDM 410 connection module, the power supply does not have to be wired separately. 1.

Ensure that the power supply to the connection module is switched off.

2.

Connect the 15-pin plug on the CLV to the corresponding socket on the CDB 410 or CDM 410 and screw it tightly. The connection cable can be extended by 2 m (6.56 ft) using the extension cable no. 6 010 075.

The data and function interfaces of the CLV are connected to the connection module. – or – External power pack: ¾

Connect the power supply to the red wire (pin 1, +VS) and the black wire (pin 5, GND) of cable no. 6 010 137. (See also Table 5-4.)

5.5.4

Connecting the host interface

The CLV provides two host interfaces in the combination RS 422/485 (interface 1) and RS 232 (interface 2), Fig. 5-2. Both interfaces operate parallel using identical communication parameters. One of the interfaces must be selected for permanent data communication with the host. If the RS 232 interface is not connected to the host, it can be used exclusively (e.g. with a PC) to monitor data traffic on the parallel RS 422/482 interface. The CLV is configured via the interface 2 by temporarily connecting a PC (see Chapter 5.5.5 Connecting the PC to the host interface 2 (RS 232), Page 5-7).

Host interface 1 RS 422 CLV 41x

Host

10

11

Host interface 2 RS 232

Host

CLV 41x

( )= 9-pin D Sub plug at PC RS 485: Connection diagram for SICK network via host interface 1 see “CLV Connect“ program on CD ROM Fig. 5-2:

8 009 974/O079/01-09-2004

Connections of the host interface

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-5

Page 46

Electrical connection

Chapter 5

Operating Instructions CLV 41x bar code scanner

Risk of damage to the interface module Electronic components in the CLV may be damaged if the host interface is connected incorrectly. ¾

Connect the host interface as shown in Fig. 5-2.

¾

Check the connections carefully before you switch on the CLV.

¾

Connect the host interface on the CLV to the host using shielded cables (EMC requirements). Ensure that the maximum cable lengths are not exceeded (Table 5-2, Page 5-3).

In the default setting, the CLV communicates with the host via the host interface using the values shown in Table 5-5, Page 5-6. Parameter

Value

Interface model host interface 1: RS 422/485 host interface 2: RS 232

Data transfer rate

9,600 bd

Data bits

8

Parity none

Stop bits

1

Protocol

SICK (start character: STX, stop character: ETX, no request for repeat: none, timeout: 50 ms)

Table 5-5: Communication parameters for the host interfaces (default setting)

TIP

The communication parameters can be changed, if necessary, on the HOST INTERFACE tab. To do so, change the values under DATA FORMAT and INTERFACE PROTOCOL. Temporarily activating the default setting of the communication parameters: Reading the profile bar codes no. 11 (see Chapter 10.4 Configuring the CLV with profile bar codes, Page 10-16 ), the CLV resets temporarily the parameters to the default setting described above if the communication parameters are different. This enables the communication with the PC only via the host interface 2 (RS 232). Reading the profile bar codes no. 12 the CLV returns to the current communication parameters. When starting the communication with the CLV, CLV Setup resets automatically the parameters in the CLV temporarily to the default setting.

For connecting the host interface via the CDB 410 or CDM 410 Connection Module, see the “CDB 410 Connection Module“ Operating Instructions (order no. 8 010 000, German/ English version) respectively the “CDM 410 Connection Module“ Operating Instructions (order no. 8 010 003, German/English version). Terminating the RS 422 interface The interface can be terminated in the CDB 410 or CDM 410 connection module. See Operating Instructions for the "CDB 410 connection module" respectively "CDM 410 connection module".

5-6

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 47

Operating Instructions

Electrical connection

Chapter 5

CLV 41x bar code scanner

5.5.5

Connecting the PC to the host interface 2 (RS 232)

The CLV is operated and configured with the"CLV Setup" program. In order to do so, you must temporarily connect the device to the PC via the host interface 2 (RS 232). Temporarily disconnect any existing electrical connection between the host interface 2 and the host! We also recommended disconnecting any existing connection between the host interface 1 (RS 422/485) and the host to avoid interferences while parameterizing the CLV. Set the communication parameters of the host interface 2 temporarily according to Table 5-5 using CLV Setup. When starting the communication with the CLV, CLV Setup automatically resets the communication parameters in the CLV after a query (see Fig. 10-5, Page 10-9). You can connect the PC to the CLV in two ways, the cable length must not exceed 10 m (32.8 ft): 1. Connecting the PC to the “Aux“ plug in CDB 410 or CDM 410 connection module Fig. 5-2, Page 5-5 shows the connection diagram of the host interface 2. For connecting the host interface 2 (RS 232) via the CDB 410 or CDM 410 Connection Module as well as setting the required switches and jumpers, see the “CDB 410 Connection Module“ Operating Instructions (order no. 8 010 000, German/ English version) respectively the “CDM 410 Connection Module“ Operating Instructions (order no. 8 010 003, German/English version). 1.

Switch off the PC and power supply to the SICK connection module.

2.

Connect the PC to the internal, 9-pin "Aux" plug of the connection module. Use a 3-core RS 232 data cable (null modem cable) for this purpose, e.g. no. 2 014 054 (RxD and TxD are crossed). CDB 410 or CDM 410 Connection Module: Set the switch S 5 (CDB 410) respectively S 7 (CDM 410) to position "RS232->AUX". – or – If a non-SICK connection module is used: Connect the PC as shown in Fig. 5-2, Page 5-5.

3.

Switch on the PC and power supply to the SICK connection module.

4.

Set the communication parameters for the PC and the CLV. (See Chapter 10.3.3 Starting "CLV Setup", Page 10-8.)

2. Connecting the PC to the optional programming adapter no. 7 034 552 The programming adapter can be inserted in the connection line between the CLV and the CDB 410 or CDM 410 connection module. The power supply is provided by the connection module. The design of the adapter is shown in Fig. 5-3. The “HOST/PROG“ switch either connects the host interface 2 (RS 232) of the CLV to the host (if wired in the connection module) or to the PC. The “CLOCK“ push button switch triggers the reading pulse, if the sensor input (Sensor 1) has been configured for reading trigger source in the CLV (default setting: reflector polling). Three LEDs indicate the activity of the switching outputs “Result 1“ to “Result 3“. The programming adapter can also be operated independently of the connection module (requires external power supply 12 V DC on “DC“ connection).

8 009 974/O079/01-09-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-7

Page 48

Electrical connection

Chapter 5

Operating Instructions CLV 41x bar code scanner

“HOST/PROG“ switch

“CLOCK“ push button switch

“CDB/CDM“ connection

DC (12 V)

LEDs for switching outputs RED: Result 1 YELLOW: Result 2 GREEN: Result 3

“CLV 41x“ connection

“PC“ connection (RS 232) Fig. 5-3:

5-8

Design of the programming adapter no. 7 034 552

1.

Switch off the PC and power supply to the SICK connection module.

2.

Connect the 15-pin connector of the CLV to the “CLV 41x“ connection (15-pin D-Sub HD socket) of the programming adapter and tight the connector (Fig. 5-4).

3.

Connect the programming adapter via the “CDB/CDM“ connection (15-pin D-Sub HDplug) to the corresponding 15-pin socket on the connection module. To do so, use the 15-core cable no. 6 010 075.

4.

Connect the COM port of the PC to the “PC“ connection (9-pin plug) of the programming adapter. To do so, use a 3-core RS 232 data cable (null modem cable), e. g. no 2 014 054 (RxD and TxD are crossed).

5.

Set the sliding switch of the programming adapter to the “PROG“ position.

6.

Switch on the PC and power supply to the SICK connection module.

7.

Set the communication parameters for the PC and the CLV (see Chapter 10.3.3 Starting "CLV Setup", Page 10-8).

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 49

Operating Instructions

Electrical connection

Chapter 5

CLV 41x bar code scanner

CDB/CDM Connection Module

HOST e. g. cable no. 6 010 075 e. g. cable no. 2 054 014 programming adapter

PC with CLV Setup CLV 41x

Fig. 5-4:

Connection of the host interface 2 (RS 232) via the programming adapter no. 7 034 552

Activating the “Sensor input“pluse mode in the CLV: 1.

Select the DEVICE CONFIGURATION tab.

2.

Click the READING TRIGGER PARAMETERS button. The READING TRIGGER PARAMETERS dialog window is then displayed.

3.

Choose SENSOR INPUT (ACTIVE HIGH) in the READING TRIGGER SOURCE section.

4.

Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog window is displayed.

5.

Confirm the dialog window by selecting the PERMANENT save option. The CLV operates with the "Sensor 1" switching input as an external trigger source.

in the toolbar.

The reading pulse starts when power is applied (press the “CLOCK“ push button switch).

8 009 974/O079/01-09-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-9

Page 50

Electrical connection

Chapter 5

Operating Instructions CLV 41x bar code scanner

5.5.6

Connecting the "Sensor 1" switching input

In the default setting the CLV is triggered by the continuous reflector polling (see Chapter 4.4.2 Installing the polling reflector, Page 4-8). If a reading process has to be triggered in the CLV by an external sensor, the reading pulse sensor must be connected to the "Sensor 1" switching input. Fig. 5-5 shows the connections for the "Sensor 1" switching input. Table 5-6 contains the characteristic data for this input. ¾

Connect the reading pulse sensor as is shown in Fig. 5-5.

CLV 41x

PNP sensor

Switch

Vin

VS= 5 to 30 V DC Fig. 5-5:

*) Vinmax= 28 V!

Connections of the "Sensor 1" switching input

Switching mode

Current at the input starts the reading interval on the CLV. (default setting: active high, debouncing: max. 20 ms (standard))

Properties optodecoupled, non-interchangeable can be connected to PNP output on a sensor

Electrical values

Low: –1V ≤ Vin ≤ +1 V –0.3 mA ≤ Iin ≤ +0.3 mA

High: +3 V ≤ |Vin| ≤ +28 V +1.4 mA ≤ |Iin| ≤ +18 mA

Table 5-6: Characteristic data of the "Sensor 1" switching input

Parameterizing an external sensor as a trigger source:

Tip

1.

Select the DEVICE CONFIGURATION tab.

2.

Click the READING TRIGGER PARAMETERS button. The READING TRIGGER PARAMETERS dialog window is then displayed.

3.

Choose SENSOR INPUT (ACTIVE HIGH) in the READING TRIGGER SOURCE section and activate the dialog box.

4.

Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog window is displayed.

5.

Confirm the dialog window by selecting the PERMANENT save option. The CLV operates with the "Sensor 1" switching input as an external trigger source. The reading pulse starts when power is applied.

You can change the switching mode (polarity, debouncing, response for first pulse after power-up) of the "Sensor 1" switching input on the DEVICE CONFIGURATION tab in the CLV Setup program. ¾

5-10 in the toolbar.

Click the READING TRIGGER PARAMETERS button. Edit dialog window. Download all changes to CLV.

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 51

Electrical connection

Operating Instructions

Chapter 5

CLV 41x bar code scanner

Reduced bebouncing Reduced bebouncing is available for time-critcial applications. The debouncing is dependent of the scanning frequency. Scanning frequency

Debouncing time

200 Hz

5 to 10 ms

300 Hz

3.3 to 6.7 ms

400 Hz

2.5 to 5 ms

500 Hz

2.0 to 4 ms

600 Hz

1.7 to 3.3 ms

700 Hz

1.4 to 2.9 ms

800 Hz

1.3 to 2.5 ms

Table 5-7: Reduced debouncing of the “Sensor 1“ switching input

For connecting the switching input via the CDB 410 or CDM 410 Connection Module, see the “CDB 410 Connection Module“ Operating Instructions (order no. 8 010 000, German/ English version) respectively the “CDM 410 Connection Module“ Operating Instructions (order no. 8 010 003, German/English version). Note

An external pulse is not required for "Percentage Evaluation" and "Read Rate Evaluation" mode. 5.5.7

Connecting the "Sensor 2" switching input

This input is used exclusively to teach in match code 1. The teach-in procedure is an alternative to entering the match code 1 on the keyboard via the CODE COMPARISION field on the DEVICE CONFIGURATION tab in CLV Setup. In order to teach in the match code, the input is connected briefly to the power supply via a switch. This can also take place in the CDB 410 or CDM 410 connection module. The characteristic data is identical to that for the "Sensor 1" input (Table 5-6, Page 5-10). Fig. 5-6 shows the connections of the switching input. ¾

Connect the sensors as is shown in Fig. 5-6.

CLV 41x

PNP sensor

Switch

Vin

VS= 5 to 30 V DC

Fig. 5-6:

8 009 974/O079/01-09-2004

*) Vinmax= 28 V!

Connections of the "Sensor 2" switching input

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-11

Page 52

Chapter 5

Electrical connection

Operating Instructions CLV 41x bar code scanner

For connecting the switching input via the CDB 410 or CDM 410 connection module, see the “CDB 410 Connection Module“ Operating Instructions (order no. 8 010 000, German/ English version) respectively the “CDM 410 Connection Module“ Operating Instructions (order no. 8 010 003, German/English version). The connections and procedure for teaching in match code 1 are described in Chapter 10.8.1 Triggering the teach-in match code 1 via the "Sensor 2" switching input, Page 10-26. 5.5.8

Connecting the "Result 1" to "Result 3" switching outputs

The three switching outputs can be assigned different functions for outputting result statuses independently of each other. If the assigned event occurs during the reading procedure, the corresponding switching output becomes live at the end of the reading pulse for the selected pulse duration. The pulse length can be set for each output independently of each other. Fig. 5-7 shows an example of how the "Result 1" switching output can be connected. Table 5-8 describes the characteristic data for the outputs. This data is identical for the three outputs. ¾

Connect the outputs as shown in Fig. 5-7. CLV 41x Pulse duration based on setting: – 10 ms to 1000 ms – 00: static (to the end of the next reading pulse)

"Result 1"

VOut

Structure of output Result 2 (pin 13) and Result 3 (pin 3) same as output Result 1

VS= 5 to 30 V DC Fig. 5-7:

Connections of the "Result 1" switching output

For connecting the switching outputs via the CDB 410 or CDM 410 connection module, see the “CDB 410 Connection Module“ Operating Instructions (order no. 8 010 000, German/ English version) respectively the “CDM 410 Connection Module“ Operating Instructions (order no. 8 010 003, German/English version). Switching mode

PNP-switching with respect to the power supply VS

Characteristics short-circuit-proof + temperature-protected, not electrically isolated from VS

Function assignment (default setting)

Result 1: "Device Ready" (static), polarity: not inverted Result 2: "Good Read" (100 ms), polarity: not inverted Result 3: "No Read" (100 ms), polarity: not inverted

Electrical values

0 V ≤ Vout ≤ VS

Guaranteed: (VS −1.5 V) ≤ Vout ≤ VS at Iout ≤ 600 mA

Table 5-8: Characteristic data of the "Result 1" to "Result 3" switching outputs

5-12

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 53

Electrical connection

Operating Instructions

Chapter 5

CLV 41x bar code scanner

Note

If the "Device Ready" function is chosen, the CLV outputs a static pulse in Reading mode. The “Result“ LED is independent of the switching outputs and lights on good read in the Reading mode until the end of the next reading pulse. In "Percentage Evaluation" mode and "Read Rate Evaluation" mode the switching outputs do not become live.

Tip

Recommendation

8 009 974/O079/01-09-2004

The output function, pulse duration (timer) and polarity of the signals can be changed on the DEVICE CONFIGURATION tab in the CLV Setup program. ¾

Click the RESULT OUTPUT PARAMETERS button. Edit dialog box. Download all changes to CLV.

¾

To check the switching functions using a high-impedance digital voltmeter, wire a load to the outputs. This prevents incorrect voltage values/switching statuses from being displayed.

© SICK AG · Division Auto Ident · Germany · All rights reserved

5-13

Page 54

Electrical connection

Chapter 5

Operating Instructions CLV 41x bar code scanner

Notes

5-14

© SICK AG · Division Auto Ident · Germany · All rights reserved