Page 29

Installation

Operating Instructions

Chapter 4

CLV 41x bar code scanner

4

Installation 4.1

Note

Overview of installation sequence

•

Change the language version of the laser warning label (if necessary)

•

Select the installation location for the CLV

•

Align the CLV with the bar code

•

Align the CLV with the polling reflector for internal reading pulse triggering

•

Mount the CLV

•

Install the CDB 410 or CDM 410 connection module

•

Connect the CLV to the CDB 410 or CDM 410 connection module

•

Adjust the CLV

•

Alternative: Install the reading pulse sensor for external triggering the reading pulse

Don’t open the device. The producer warranty will be forfeited if the device is opened.

4.2

Installation preparations

4.2.1

Laying out required components to be installed

•

CLV 41x bar code scanner

4.2.2 •

Laying out accessories

Small mounting bracket no. 2 020 077 or large mounting bracket no. 2 020 078 with 2 x M4 x 8 mm (0.32 in) screws for installing the bracket to the CLV (not included with the CLV) – or – Alternatively, if the bracket is supplied by the user: – Stable installation device that allows the alignment of the CLV to be varied in the x and y axes. The maximum weight of the CLV (line/raster scanner) is 250 g (8.8 oz), or approx. 320 g (11.3 oz) with additional attachment (with cable). – Two M4 screws for the CLV. The screw length depends on the wall thickness of the bracket used. Depth of engagement in CLV max. 6 mm (0.24 in) from housing surface.

•

CDB 410 or CDM 410 connection module (not included with CLV)

•

Polling reflectors for automatic internal generation of the reading pulse trigger – or –

•

Reading pulse sensor for external reading pulse trigger, e.g. photoelectric reflex switch/photoelectric proximity switch (not included with the CLV)

4.2.3

8 009 974/O079/01-09-2004

Laying out other required materials

•

Two M4 screws for securing the SICK mounting bracket to the base. The screw length depends on the wall thickness of the base.

•

Set of laser warning labels (if necessary)

•

Tools

•

Measuring tape (up to 1 m (39.4 in))

•

Protractor

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-1

Page 30

Chapter 4

Installation

Operating Instructions CLV 41x bar code scanner

4.2.4

Replacing the laser warning label

If necessary, replace the laser warning label in GB English/US English on the CLV with the required language (Fig. 4-1). The device is delivered with a set of laser warnings in: •

German/US English

•

French/US English

See also Chapter 2.3 General safety instructions and protection measures, Page 2-2.

Included label set:

Fig. 4-1:

4.2.5

Example line scanner: replacing the laser warning label

Selecting the installation location

When you select the installation location, the distance between the CLV and the host and between the CLV and the bar code are important. Distance between the CLV and the host The CLV can be installed without a connection to a bus connection max. 1,200 m (3,936.9 ft) away from the host. The distance which can be achieved depends on the selected type of the host interface and the set data transfer rate, however. See Table 5-2, Page 5-3. Distance between the CLV and the CDB 410 or CDM 410 connection module The CDB 410 or CDM 410 connection module must not be located further than 10 m (32.8 ft) from the CLV, since the "CLV Setup" program on the PC accesses the host interface 2 of the CLV via the module (RS 232). 4.2.6

Mounting accessories

The CLV is mounted with the help of two tapped blind holes (M4) located on the bottom narrow side of the device. Fig. 4-2 shows the position of the threaded hole for both housing models. The complete dimensions of the CLV housing are shown in Fig. 9-1, Page 9-3.

4-2

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 31

Installation

Operating Instructions

Chapter 4

CLV 41x bar code scanner

10 (.39)

35.2 (1.39) 4 (.15)

32.8 (1.29)

59 (2.32)

10 (.39)

M4, 6 (.24) deep

45.8 (1.80)

72 (2.84)

35.2 (1.39) 4 (.15)

M4, 6 (.24) deep

All dimensions in mm (in) Fig. 4-2:

Location of the securing threads on the CLV

The CLV can be installed using the following SICK brackets: •

Small mounting bracket, no. 2 020 077

•

Large mounting bracket, no. 2 020 078

The brackets are designed to support a variety of installation positions and alignments of the CLV in two planes. Fig. 4-3 shows a mounting example. The slots in the brackets allow a turning freedom of ±15° for the fine adjustment of the CLV.

Fig. 4-3:

8 009 974/O079/01-09-2004

Installation example: mounting the CLV with mounting bracket no. 2 020 077

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-3

Page 32

Chapter 4

Installation

Operating Instructions CLV 41x bar code scanner

4.2.7

Distance between the CLV and the bar code

Basic alignment of the scan line to the bar code Depending on the application, the line scanner or raster scanner version of the CLV is used. Fig. 4-4 shows how the device is aligned with the bar code on the object for each of the two scanning methods. Line scanner

Fig. 4-4:

Raster scanner

Scanning methods: alignment with bar code and conveyor direction

Reading distance between bar code and aperture angle α The distance between the reading window of the CLV and the bar code must not exceed the technical limits. The height of the reading field is shown as a function of the reading distance “a“ for various resolutions (module widths) in Chapter 10.2 Specification diagrams, Page 10-1. Fig. 4-5 shows the definition of the reading distance “a“ from the reading window and of the aperture angle α for each of the two scanning methods.

Fig. 4-5:

Line scanner

Raster scanner

Reading distance a

Reading distance a

Definition of the reading distance a and the aperture angle α

For both scanning methods, the useable aperture angle α is max. 60° with front reading window and max. 50° with side reading window (additional 105° angle attachment). Due to the V-principle of beam deflection, the reading field height (for evaluating the useful length of the scan line) depends on the reading distance.

4-4

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 33

Operating Instructions

Installation

Chapter 4

CLV 41x bar code scanner

Angular alignment of the CLV Optimum alignment of the CLV is achieved when the scan line travels over the bar code lines almost at a right angle (90°) (Fig. 4-4). All possible reading angles that can occur between the scan line and the bar code must be taken into consideration (Fig. 4-6 and Table 4-1).

β

α Reading area

α: Azimuth angle (tilt) β: Inclination angle (pitch) γ: Rotation angle (skew)

γ Reading distance Fig. 4-6:

Line scanner: reading angles between the scan line and the bar code

Angle

Limit

Azimuth α (tilt)

max. 15° (depending on the code print)

Inclination β (pitch)

max. 45° (depending on the module width)

Skew γ max. 45° (depending on the module width)

Table 4-1: Permissible reading angles between the scan line and bar code

Preventing surface reflection If the light from the scan line strikes the surface of the bar code perpendicularly, interference may be caused by reflections when the returned light is received. To prevent this effect, the CLV must be installed in such a way that the emitted light is tilted slightly with respect to the vertical axis. Fig. 4-7 shows an example of this using the line scanner. Line scanner (front reading window)

Line scanner with 105° angle attachment (side reading window)

105°

105° top view

Fig. 4-7:

top view

Preventing surface reflection: angle between the emitted light and bar code (tilted away from the vertical axis)

The laser beam from the line/raster scanner with angle attachment is emitted at an angle of 105° with respect to the housing. Depending on the application, the device can also be installed flush with the conveyor belt.

8 009 974/O079/01-09-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-5

Page 34

Installation

Chapter 4

Operating Instructions CLV 41x bar code scanner

4.2.8 Explanation

Count direction of the code position CP

The CLV can scan and decode several bar codes with each read. In doing so, it determines the specific local reading diagnosis data for each bar code, i.e. the position (CP value) of the center of the bar code within the scan line. Fig. 4-4 shows the count direction of the code position. By determining the CP value, the device can separate identical bar codes (code type, code length, and data content) and assign the bar code data in the reading result to its position on the object.

Line/raster scanner

Line/raster scanner with angle attachment

100 100 CP CP 0 0 Front reading window

Side reading window

Deflection angle α (aperture angle) in scan direction: 1° = 2 CP (50° = 100 CP) Fig. 4-8:

Count direction of the code position CP within the scan line

Tip

In the default setting, the CLV does not output the value "CP" in the reading result of the host interface. If this is required to evaluate the result in the host, the values can be included in the Separator of the output string using the CLV Setup program. Configuring the Separator:

4-6

1.

Select the DATA STRINGS tab.

2.

Click the SEPARATOR field. The dialog window EDIT PARAMETER: TFS dialog box is displayed.

3.

In the drop-down list, click the CP parameter. CP then appears on the top line.

4.

Confirm the dialog box with "OK".

5.

Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog box is displayed.

6.

Confirm the dialog box by selecting the PERMANENT save option. The CLV outputs the CP value for each bar code in the reading result via the host interface. The values are displayed as a 3-digit number in the associated Separator.

© SICK AG · Division Auto Ident · Germany · All rights reserved in the toolbar.

8 009 974/O079/01-09-2004

Page 35

Operating Instructions

Installation

Chapter 4

CLV 41x bar code scanner

4.3

Installing and adjusting the device

4.3.1

Installing the CLV

1.

Prepare the base for installing the bracket as described in Chapter 4.2.2 Laying out accessories, Page 4-1.

2.

Place the object containing the bar code within the visible range of the CLV (in the position at which it is to be read) with the conveyor belt switched off.

3.

Align the CLV with the bar code (in accordance with the scanning method) in such a way that – with the line/raster scanner, the narrow end with the LED indicators is almost parallel with the bar code surface – with the line/raster scanner with angle attachment, the wide side with the laser warning labels is almost parallel with the bar code surface All of the possible reading angles must be taken into consideration. See Fig. 4-6, Page 4-5.

4.

If relevant to the evaluation, pay attention to the count direction of the code position if applicable. See Fig. 4-8, Page 4-6.

5.

Install the CLV bracket on the base.

Risk of damage to the device The maximum depth of engagement of the two tapped blind holes M4 is 6 mm (0.24 in). Longer screws will damage the device. ¾

Use screws with the correct length.

6.

Screw the M4 screws through the bracket into the tapped blind holes of the CLV.

7.

Tighten the screws slightly.

8.

Adjust the CLV as described below.

4.3.2

Adjusting the CLV

The "percentage evaluation" mode supports the adjustment of the CLV. In this mode, the CLV displays the quality of the bar code reads that enter the CLV reading field statically (the object is not moved on the conveyor belt). The CLV performs 100 scans in Free Running mode and evaluates the reading quality statistically. It outputs the reading result continuously every 2 s via the host interfaces. The behavior of the "Result" LED also indicates the reading quality:

8 009 974/O079/01-09-2004

–

LED is extinguished if reading quality is < 30 %

–

LED flashes twice per second if the reading quality is 30 % to 70 %

–

LED flashes five times per second if the reading quality is 70 % to 90 %

–

LED is lit continuously if the reading quality is > 90 %

1.

Connect the CLV to the CDB 410 or CDM 410 connection module and switch on the power supply to the module (see Chapter 5.5.3 Connecting the power supply, Page 5-5). Once the CLV has started, it outputs a tone to indicate that the self-test was successfully completed. Shortly afterwards, it outputs two tones to indicate that it has assumed Reading mode. The "Device Ready" LED lights up.

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-7

Page 36

Chapter 4

Installation

Operating Instructions CLV 41x bar code scanner

2.

Connect the PC to the host interface 2 of the CLV. For this purpose, connect a 3-core RS 232 data cable (null modem cable) to the internal 9-pin "Aux" plug of the module (see Chapter 5.5.5 Connecting the PC to the host interface 2 (RS 232), Page 5-7).

3.

Start Windows and "CLV Setup" on your PC (see Chapter 10.3.3 Starting "CLV Setup", Page 10-8).

Activating “Percentage Evaluation“ mode: 4.

From the VIEW menu, choose PERCENTAGE EVALUATION. The Terminal Emulator is launched and displays the reading result continuously (see Chapter 6.5.2 Percentage evaluation, Page 6-17). Monitor the reading quality (%) during each of the subsequent steps!

Performing fine adjustment: 5.

Align the CLV in such a way that the angle between the scan line and the bars on the bar code CLV is almost 90°.

6.

To prevent interfering reflections, tilt the CLV away from the vertical axis so that the light strikes the bar code at an angle of approx. 105° (line scanner) (Fig. 4-7, Page 4-5).

7.

If necessary, position the center of the red scan line exactly on the bar code (see Chapter 4.4 Installing external components, Page 4-8).

8.

Move objects carrying bar codes into the CLV reading field manually under realistic conditions and check the reading result. If the objects are aligned randomly, or if the bar code is located at different positions (angles), ensure that the limit values of the permissible reading angles are not exceeded.

9.

Adjust the CLV in such a way that the good read rate is between 70 and 100 %.

10. Tighten the screws on the CLV. The CLV is aligned with the bar code.

4.4

Installing external components

4.4.1

Installing the CDB 410 or CDM 410 connection module

1.

Install the CDB 410 or CDM 410 connection module near the CLV. The distance between the connection module and CLV must not exceed 10 m (32.8 ft).

2.

Install the CDB 410 or CDM 410 in such a way that the device can be accessed when opened. The host interface 2 (RS 232) of the CLV is accessed via the internal 9-pin "Aux" connector.

Detailed information on the installation and electrical installation procedures is provided in the “CDB 410 Connection Module“ Operating Instructions (order no. 8 010 000, German/English version) respectively in the “CDM 410 Connection Module“ Operating Instructions (order no. 8 010 003, German/English version). 4.4.2

Installing the polling reflector

The reading pulse can also be triggered by the presence of an object in the reading field, independent of an external reading pulse sensor, by using the "Reflector Polling" pulse mode of the CLV. In order to do so, attach one of the two polling reflectors (special bar codes) included with the device opposite the CLV behind the conveyor belt (Fig. 4-9). Table 4-2 lists the permissible range values for the polling reflectors. The pulse type is selected in the default setting.

4-8

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 37

Installation

Operating Instructions

Chapter 4

CLV 41x bar code scanner white blue

Polling reflector

15° Fig. 4-9:

50 mm = 1.97 in / 144 mm = 5.67 in

Line scanner: installation location of the polling reflector

Device type

Reflector

Range (scanning frequency 500 Hz)

CLV 410 white blue

40 to 500 mm (1.58 to 19.7 in) 500 to 800 mm (19.7 to 31.5 in)

CLV 412 blue

150 to 350 mm (5.9 to 13.8 in)

CLV 414 blue

230 to 650 mm (9 to 24.4 in)

Table 4-2: Permissible range values for the polling reflectors

Explanation

When reflector polling is used, the CLV activates the laser diode with every 20th scan and checks whether it detects the reflector. If the reflector is visible, the CLV repeats the procedure after the next 20 scans. If the reflector is concealed by an object entering the reading field, the CLV starts the reading pulse. This pulse ends when the CLV detects the reflector again. Following this, the CLV repeats the above procedure. When the CLV is switched on, the polling reflector must be visible before the first reading pulse can start. The CLV does not output the data content of the polling reflector in "Reading" mode.

Note

This pulse mode is not suitable for applications where time is critical. The max. delay between the reliable detection of the reflector and the start of the internal reading interval is approx. 100 ms at a scanning rate of 200 Hz. Adjusting the polling reflector roughly:

8 009 974/O079/01-09-2004

1.

Connect the CLV to the CDB 410 or CDM 410 connection module and switch on the power supply to the module (see Chapter 5.5.3 Connecting the power supply, Page 5-5). Once the CLV has started, it outputs a tone to indicate that the self-test was successfully completed. Shortly afterwards, it outputs two tones consecutively to indicate that it has assumed Reading mode. The "Device Ready" LED lights up.

2.

Align the CLV optimally with the bar code on the object (see Chapter 4.3.2 Adjusting the CLV, Page 4-7).

3.

Choose a suitable polling reflector for the device type, as shown in Table 4-2. Other ranges available on request.

4.

Secure the polling reflector directly opposite the CLV on a suitable base (movable bracket, wall) temporarily so that the CLV has an unobstructed view of the reflector in the gaps between the objects and can scan them reliably. The reflector must be in the center of the scan line, see Fig. 4-9.

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-9

Page 38

Installation

Chapter 4

Operating Instructions CLV 41x bar code scanner

Activating “Percentage Evaluation“ mode: 5.

From the VIEW menu, choose PERCENTAGE EVALUATION. The Terminal Emulator is launched and displays the reading result continuously (see Chapter 6.5.2 Percentage evaluation, Page 6-17).

Fine-adjusting and securing the polling reflector: 6.

Align the reflector with the CLV (not vice versa!) until a good read rate of 95 to 100 % is reached. In doing so, prevent any surface reflection (see Chapter 4.2.7 Distance between the CLV and the bar code, Page 4-4). The CLV outputs the data content of the unconcealed polling reflector with the identifier "REPO".

7.

Once the device is in the final attachment position, remove the protective film from the rear of the reflector and stick it to the base.

8.

Check whether the device operates correctly with objects moving under realistic conditions on the conveyor belt. Readjust the reflector if necessary.

Activating “Reflector Polling pulse“ mode in the CLV (N/A with default setting): 1.

Select the DEVICE CONFIGURATION tab.

2.

Click the READING TRIGGER PARAMETERS button. The READING TRIGGER PARAMETERS dialog window is displayed.

3.

Activate the REFLECTOR POLLING option in the READING TRIGGER SOURCE section.

4.

Confirm the dialog box with "OK".

5.

Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog window is displayed.

6.

Confirm the dialog window by selecting the PERMANENT save option. The CLV is then operating in the "reflector polling" pulse mode.

4.4.3 in the toolbar.

Alternative: Installing the external reading pulse sensor

If the CLV is triggered by an external reading pulse sensor, the sensor must be mounted in the vicinity of the CLV and be connected to the "sensor 1" switching input. The pulse type is not selected in the default setting. Fig. 4-10 shows two examples of where a photoelectric reflex switch can be installed. This depends on the distance a from the bar code to the front edge of the object. Depending on the application, you may need to attach the sensor in such a way that bar codes on objects of different sizes can be read completely during the reading interval. Bar code in the middle or at the end of the moved object

Bar code at the beginning of the moved object a a b Fig. 4-10:

4-10 b<a b b<a

Line scanner: installation example for the external reading pulse sensor

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004

Page 39

Operating Instructions

Installation

Chapter 4

CLV 41x bar code scanner

1.

Attach the reading pulse sensor to the installation location.

2.

Connect the reading pulse sensor to the "Sensor 1" switching input of the CLV via the CDB 410 or CDM 410 connection module (see Chapter 5.5.6 Connecting the "Sensor 1" switching input, Page 5-10).

3.

Connect the CLV to the CDB 410 or CDM 410 connection module and switch on the power supply to the module (see Chapter 5.5.3 Connecting the power supply, Page 5-5). After the CLV has started, it emits a tone to indicate that the self-test was successful. After a short while, it outputs two consecutive tones to indicate that it has switched to Reading mode. The "Device Ready" LED lights up.

4.

Connect the PC to the host interface 2 of the CLV. For this purpose, connect a 3-core RS 232 data cable (null modem cable) to the internal 9-pin "Aux" plug of the module. (See Chapter 5.5.5 Connecting the PC to the host interface 2 (RS 232), Page 5-7.)

5.

Start Windows and "CLV Setup" on your PC (see Chapter 10.3.3 Starting "CLV Setup", Page 10-8).

Parameterizing an external sensor as a trigger source: 6.

Select the DEVICE CONFIGURATION tab.

7.

Click the READING TRIGGER PARAMETERS button. The READING TRIGGER PARAMETERS dialog window is then displayed.

8.

Choose SENSOR INPUT (ACTIVE HIGH) in the READING TRIGGER SOURCE section and activate the dialog box.

9.

Perform a download to the CLV. This is done by clicking The DOWNLOAD PARAMETER dialog window is displayed.

in the toolbar.

10. Confirm the dialog window by selecting the PERMANENT save option. The CLV operates with the "Sensor 1" switching input as an external trigger source. The reading pulse starts when power is applied. Carrying out a test reading: 11. From the VIEW menu, choose READING MODE. The Terminal Emulator window is then displayed. The CLV is in Reading mode. Monitor the reading result during each of the subsequent steps! 12. Move objects with bar codes into the CLV reading field manually under realistic conditions. 13. Check whether the reading result and trigger pulse are correct. 14. Repeat the procedure with the conveyor switched on. Check whether the reading procedure is synchronized with the approaching objects.

4.5

Removing the device

1.

Switch off the power supply to the CDB 410 or CDM 410 connection module.

2.

Loosen the screws and remove the CLV connector from the connection module.

3.

Unscrew the CLV from the installation device.

When removing the device from service for the last time, please dispose of it in an environmentally-friendly manner, as described in Chapter 7.3 Disposal, Page 7-2.

8 009 974/O079/01-09-2004

© SICK AG · Division Auto Ident · Germany · All rights reserved

4-11

Page 40

Installation

Chapter 4

Operating Instructions CLV 41x bar code scanner

Notes

4-12

© SICK AG · Division Auto Ident · Germany · All rights reserved

8 009 974/O079/01-09-2004