Page 87
Operating Instructions
Technical data
Chapter 9
CLV 41x bar code scanner
9
Technical data 9.1
Type
Data sheet CLV 41x bar code scanner (fixed focus) CLV 410 (Standard)
CLV 412 (High Density)
CLV 414 (Short Range)
Line scanner
CLV 410-0010
CLV 412-0010
CLV 414-0010
Raster scanner
CLV 410-1010
CLV 412-1010
CLV 414-1010
Line scanner with 105° angle attachment
CLV 410-2010
CLV 412-2010
CLV 414-2010
Raster scanner with 105° angle attachment CLV 410-3010
CLV 412-3010
CLV 414-3010
Focus
Fixed focus
Reading window
Line/raster scanner: front Line/Raster scanner with angle attachment: side (angle of emergence 105°)
Laser diode (wavelength)
red light (λ = 670 nm)
MTBF of laser diode
20,000 h
Laser class of device
Class 2 (pursuant to DIN EN 60825-1), shutoff of laser diode after 10 min1)
Useable aperture angle max. 60°(front reading window)/max. 50° (side reading window)
Scanning/decoding frequency
200 to 800 Hz
Resolution
0.2 to 1.0 mm (7.8 to 39.4 mil)
0.1 to 0.2 mm (3.94 to 7.8 mil)
0.2 to 0.5 mm (7.8 to 19.7 mil)
Reading range
50 to 380 mm (1.97 to 14.97 in)
45 to 92 mm (1.77 to 3.62 in)
42 to 97 mm (1.65 to 3.82 in)
Raster height
15 mm (0.6 in) (8 lines) at a reading distance of 200 mm (7.9 in) (front reading window)
Bar code print contrast (PCS)
≥ 60 %
Immunity to ambient light
2,000 lx (on bar code)
No. of bar codes per scan
1 to 3
No. of bar codes per reading interval
2)
1 to 10 (autodiscriminating)
Bar code types
Code 39, Code 128, Code 93, Codabar, EAN, EAN 128, UPC, 2/5 Interleaved, Pharmacode
Bar code length max. 50 characters (max. 100 characters across all bar codes per reading interval)
Print ratio
2:1 to 3:1
No. of multiple reads
1 to 99
Visual indicators
4 x LEDs
Acoustic indicator
Beeper, can be deactivated and assigned to a function for result status indication
Reading pulse
Reflector polling/"Sensor 1" switching input/ser. interface/free running/Continuous Read
"Host" data interfaces
RS 232 and RS 422/485, variable data output format
Data transfer rate
300 to 57,600 bd
Protocols
SICK Standard, SICK Network
Physical configurations
Standalone, SICK Network (bus), Daisy Chain (pass-through or master/slave)
Switching inputs
2 ("Sensor 1", "Sensor 2") – optodecoupled, Vimax = 30 V, non-interchangeable, can be connected to PNP outputs – "Sensor 1" (reading pulse): max. internal delay 20 ms/reduced max 2.5 ms – "Sensor 2" (teach-in matchcode): max. internal delay 20 ms
1) default setting, in Reading mode with the "Sensor 1 switching input" and "Serial interface" pulse types 2) Reading interval: time window generated internally for evaluating the code
Table 9-1: Technical specifications of the CLV 41x (line/raster scanner)
8 009 974/O079/01-09-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
9-1
Page 88
Chapter 9
Technical data
Operating Instructions CLV 41x bar code scanner
Type
CLV 410 (Standard)
CLV 412 (High Density)
CLV 414 (Short Range)
Switching outputs
3 ("Result 1" to "Result 3") – PNP, Iomax = 600 mA, short-circuit-proof, variable pulse duration (stat., 10 to 1000 ms) – Variable output function for result status
Electrical connection
15-pin D Sub HD connector, cable length 0.9 m (35.5 in)
Operating voltage3)/power consumption
5 to 30 V DC pursuant to IEC 364-4-41 (VDE 0100 (Teil 410))/max. 3 W
Housing
Zinc die-cast, does not represent a problem in paint shops
Enclosure rating/Protection class
IP 65 (to DIN 40 050)/Class 3 (to VDE 0106/IEC 1010-1)
EMC/vibration/shock tested persuant to EN 61000-6-3, EN 61000-6-2/persuant to IEC 68-2-6 Test FC/pursuant to IEC 68-2-27 Test EA
Weight
250 g (8.8 oz) with connecting cable (with side 105° angle attachment : approx. 320 g (11.3 oz))
Operating/storage temperature
0 to +40 °C/–20 to +70 °C (+32 to 104 °F/–4 to + 158 °F)
Max. rel. humidity
90 %, non condensing
Color
SICK blue (RAL 5012)
3) The CLV 41x is UL certificated when a class 2 power supply according to UL 1310 is used.
Table 9-1: Technical specifications of the CLV 41x (line/raster scanner) (contd.)
9-2
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 974/O079/01-09-2004
Page 89
Technical data
Operating Instructions
Chapter 9
CLV 41x bar code scanner
9.2
CLV dimensional drawings
CLV 41x-0xxx/-1xxx Line/Raster scanner with front reading window: 6
Device Ready Result LASER ON Data
Made in Germany
10 (.39) 14.4 (.57) 13.2 (.52)
35.2 (1.39)
4 (.16)
32.8 (1.29)
59 (2.32)
0.2 (.008)
M4, 6 (.24) deep
43.3 (1.70) 62.5 (2.46)
15.3 (.60)
Laser radiation when open DO NOT STARE INTO BEAM
60
CAUTION
: 1,2 mW Pulse duration : 223 s : 670 nm EN 60825-1 : 1994 + A11 : 1996
LASER RADIATON DO NOT STARE INTO BEAM CLASS 2 LASER PRODUCT
Max, output radiation Emitted wavelength
: 1,2 mW Pulse duration : 111 s : 670 nm Compiles with 21CFR 1040,10
LASER LIGHT DO NOT STARE INTO BEAM CLASS II LASER PRODUCT
C A U T I O N
Max, output Wavelength
39.3 (1.55)
62.7 (2.47)
Dimensions in mm (in)
Line/Raster scanner with side reading window:
Fig. 9-1:
Dimensions of the CLV 41x line/raster scanner
8 009 974/O079/01-09-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
9-3
Page 90
Technical data
Chapter 9
Operating Instructions CLV 41x bar code scanner
Notes
9-4
© SICK AG · Division Auto Ident · Germany · All rights reserved