For the Sick CLV410, Sick CLV412 and Sick CLV414
Page 91
Appendix
Operating Instructions
Chapter 10
CLV 41x bar code scanner
10
Appendix 10.1
Overview
The Appendix contains the following additional information: •
Specification diagrams – Line/Raster scanner – Line/Raster scanner with 105° angle attachment
•
Installation and operating instructions for the PC-based "CLV Setup" program
•
Configuring the CLV with profile bar codes
•
Configuring the CLV with commands
•
Calculating parameter values for setting the CLV
•
Tables
•
Special applications and procedures
•
Replacing a CLV (copying the parameter set)
•
Accessories
•
Dimensional drawings of the accessories
•
Supplementary documentation
•
Glossary
•
Copy of the EC Declaration of Conformity
•
Index
•
Scannable sample bar codes
10.2
Specification diagrams
10.2.1
Reading conditions for all diagrams
Test code
Code 39/ITF
Print ratio
2:1
Print contrast
> 90 %
Tilt
±10°
Ambient light
< 2,000 lx
Good read rate
> 75 %
Table 10-1: Reading conditions for specification diagrams
Raster scanner: raster height 15 mm (0.59 in) at 200 mm (7.88 in) reading distance Note
Line/raster scanner with 105° angle attachment: the whole reading range shifts by 15 mm (0.59 in) towards the reading window. The maximum aperature angle is 50°.
8 009 974/O079/01-09-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-1
Page 92
Appendix
Chapter 10
Operating Instructions CLV 41x bar code scanner
10.2.2
Reading field diagram for CLV 410 line/raster scanner (standard)
Line/raster scanner with front reading window:
a: 0.20 (7.9 mil) b: 0.35 (13.8 mil) c: 0.50 (19.7 mil) d: 1.00 (39.4 mil)
Dimensions in mm (in)
[Hz] 0.20 mm (7.9 mil) 0.35 mm (13.8 mil) 0.50 mm (19.7 mil) 1.00 mm (39.4 mil)
General reading conditions: see Table 10-1, Page 10-1 [mm (in)]
Fig. 10-1:
10-2
CLV 410-0010/1010: reading range (DOF) and scanning frequency characteristic for line/raster scanner (standard)
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 974/O079/01-09-2004
Page 93
Operating Instructions
Appendix
Chapter 10
CLV 41x bar code scanner
10.2.3
Reading field diagram for CLV 412 line/raster scanner (high density)
Line/raster scanner with front reading window:
a: 0.10 (3.9 mil) b: 0.15 (5.9 mil) c: 0.20 (7.9 mil) Code 0.1 mm (3.9 mil): Print ratio 3:1 Code 0.15 mm (5.9 mil): Print ratio 3:1 Code 0.2 mm (7.9 mil): Print ratio 2:1
Dimensions in mm (in)
0.10 mm (3.9 mil) 0.15 mm (5.9 mil) 0.20 mm (7.9 mil)
General reading conditions: see Table 10-1, Page 10-1
Fig. 10-2:
CLV 412-0010/1010: reading range (DOF) and scanning frequency characteristic for line/raster scanner (high density)
8 009 974/O079/01-09-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-3
Page 94
Chapter 10
Appendix
Operating Instructions CLV 41x bar code scanner
10.2.4
Reading field diagram for CLV 410-2010 S02 line scanner (side reading window)
Line scanner, optimized for module width 0.35 mm (13.8 mil) and 0.5 mm (19.7 mil):
a: 0.35 (13.8 mil) b: 0.50 (19.7 mil) Code 0.35 mm (13.8 mil): Print ratio 2:1 Scanning frequency 250 Hz Code 0.50 mm (19.7 mil): Print ratio 2:1 Scanning frequency 300 Hz
Dimensions in mm (in)
General reading conditions: see Table 10-1, Page 10-1
Fig. 10-3:
CLV 410-2010 S02: reading range (DOF) for line scanner
10.2.5
Reading field diagram CLV 414 line scanner (short range)
Line scanner, optimized for short reading distances:
Code 0.2 mm (7.9 mil): Print ratio 2:1
Dimensions in mm (in)
Fig. 10-4:
10-4
General reading conditions: see Table 10-1, Page 10-1
CLV 414-0010: reading range (DOF) for line scanner (short range)
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 974/O079/01-09-2004
Page 95
Appendix
Operating Instructions
Chapter 10
CLV 41x bar code scanner
10.3
Installation and operating instructions for the PC-based "CLV Setup" program
The scope of delivery of the CLV includes a CD ROM (“Manuals & Software“) containing the "CLV Setup" program. The following is required to run the program: a PC with at least an 80486 processor running at 66 MHz, 16 MB RAM, CD ROM drive, serial interface, mouse (recommended) and Windows 95TM/98TM, Windows NT4.0TM, Windows 2000TM or Windows XPTM. Approximately 25 MB of hard disk space is required to install CLV Setup (V 4.10) and CLV Assistant, approximately 20 MB to install CLV Setup Help (V 4.10). For the lastest version of the software, see www.sick.com. 10.3.1
Preparations for installation
1.
Make sure you have the CD ROM (“Manuals & Software“) at hand.
2.
Connect the CLV to the CDB 410 or CDM 410 connection module. (See Chapter 5.5.3 Connecting the power supply, Page 5-5.) Temporarily disconnect any existing electrical data connection to the host!
3.
Connect the PC to the host interface 2 of the CLV using a 3-core RS 232 data cable (null modem cable) (CDB 410 or CDM 410: connect the PC to the internal, 9-pin "Aux" plug). See Chapter 5.5.5 Connecting the PC to the host interface 2 (RS 232), Page 5-7.
4.
Switch on the power supply to the CDB 410 or CDM 410. Once the CLV has started, it outputs a tone to indicate that the self-test was successfully completed. Shortly afterwards, it outputs two consecutive tones to indicate that it has assumed Reading mode. The "Device Ready" LED lights up.
5.
Switch on your PC and start Windows.
10.3.2
Installation
The CLV Setup installation program creates a directory called "CLV", a series of subdirectories and the necessary links. Using the included uninstaller, CLV Setup can be completely removed from the PC. As of version V2.6, CLV Setup will only be available and further developed as a 32-bit application. Note
The following instructions describe how to install the software on Windows 95TM. These instructions may differ depending on the operating system you are using (for example, administrator rights are required to install the software on Windows NT4.0). Initial installation 1. Shut down all the applications running in Windows. 2. Insert the CD ROM into the CD ROM drive. 3. If the auto run function is enabled, the start page (table of contents) of the CD ROM is automatically displayed in the your browser. 4. Select the SOFTWARE folder on top left. 5. Select CLV, ICR, OPS SETUP SOFTWARE in the listing. A table with CLV Setup information is displayed. 6. Select DOWNLOAD under SOFTWARE FILE. 7. In the FILE DOWNLOAD dialog box select the option to install directly from the CD ROM. Confirm with OK. The software is automatically saved in the “Programs\CLV“ directory on your hard disk.
8 009 974/O079/01-09-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-5
Page 96
Chapter 10
Appendix
Operating Instructions CLV 41x bar code scanner
– or – Select the option to save the software locally on your local hard disk and confirm with OK. In the FILE DOWNLOAD dialog box select the desired target directory on your hard disk. The “CLVSetupxx.exe“ file is then saved at this location (xx = version number). Select OPEN in the dialog box to start the file. 8.
The installation program starts and guides you through the installation with screen messages. The program asks you for your user name and company name. This information appears as a header in printouts. “CLV Setup“ and CLV Assistant are installed. The software will be entried in the Windows start menu under “Programs\CLV Setup“.
9.
Please read the Readme file, as it contains the latest information and problems regarding CLV Setup.
10. Then confirm the final installation message by clicking “OK“. CLV Setup Help (Online) 1.
Return to the start page of the CD ROM with the opened folder “Software“.
2.
Select CLV, CLV HELP SOFTWARE in the listing. A table with CLV Help information is displayed.
3.
Select DOWNLOAD under SOFTWARE FILE.
4.
In the FILE DOWNLOAD dialog box select the option to install directly from the CD ROM. Confirm with OK. The software is automatically saved in the “Programs\CLV“ directory on your hard disk. – or – Select the option to save the software locally on your local hard disk and confirm with OK. In the FILE DOWNLOAD dialog box select the same target directory as selected for CLV Setup on your hard disk. The “CLVHelp.exe“ file is then saved at this location.
5.
After downloading the software, select OPEN in the dialog box to start the software. The software is installed in the sub directory “Help“ of the main directory “CLV“. CLV Help will also be entried in the Windows start menu under “Programs\CLV Setup“.
¾
Restart the PC. Some Windows DLL files are possibly updated.
The “CLV Setup“ program, the CLV Assistant and the online “CLV Setup Help“ are installed and ready. The program logs all of the files that are installed to the “install.log“ file. This list is used by the uninstaller to remove CLV Setup and must not be deleted if you want to use the uninstaller at some time in the future. Updating program There are two options for installing a new version of CLV Setup: •
You can install the new version and still keep the old version (parallel installation)
– or – •
10-6
You can install the new version over the old version (overwrite)
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 974/O079/01-09-2004
Page 97
Operating Instructions
Appendix
Chapter 10
CLV 41x bar code scanner
Installing new version and retaining old version If you want to install the new version and still keep the old version of CLV Setup, follow the procedure described under Initial installation. When the program asks you for the target directory, you must specify a new directory. Both versions of the software are then available but may not be started simultaneously. The configuration files "*.scl" of the old version can be used in the new version and contain the CLV parameter sets. In order to do so, copy the configuration files from the "data" directory of the old version to the "data" directory of the new version. Installing new version over old version When installing the new version over the old version, the files of the old version must first be deleted (exception: the "*.scl" configuration files). They contain the parameter sets of the CLV. The uninstaller of the old version removes the program files. You can use the uninstaller to remove all of the files (with the exception of the configuration files) or only selected files. The default setting is a complete uninstall (the configuration files are not deleted). With the custom uninstall, the files are listed and only selected files are uninstalled. If you choose this uninstall method, ensure that the main directory containing the configuration files "*.scl" is not deleted. We recommend that you move these files to a different directory and copy them back to the "data" directory later. 1.
From the Windows Start menu, choose "Programs" and the uninstaller for CLV Setup. The uninstaller starts and guides you step by step through the uninstall procedure.
2.
Select the uninstall method (complete or custom).
3.
Install the new version of CLV Setup as described under Initial installation. Select the same directory.
The new version of CLV Setup is installed. The configuration files of the old version can be used again.
8 009 974/O079/01-09-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
10-7
Page 98
Chapter 10
Appendix
Operating Instructions CLV 41x bar code scanner
10.3.3
Starting "CLV Setup"
The "CLV Setup" program is launched with the following default settings: Communication
COM 1; 9,600 bd; 8 data bits; 1 stop bit; no parity
Transmit control character
Start: STX, Stop: ETX
Receive control character
Start: STX, Stop: ETX
Unit of measure metric (depending on the selected installation)
Browser user dependent
Language as selected for the installation
Company name as entered for the installation
User name as entered for the installation
Establish connection to CLV automatically at startup: yes on scanner selection: yes when the terminal emulator is started/closed: yes
Initial screen yes
Storage confirmation prompt yes
Last type selected
CLV 41x
File storage location
"data" (configuration files for CLV)
Table 10-2: Default settings of CLV Setup (extract)
1.
Switch on your PC and start Windows.
2.
Select CLV SETUP from the Start menu. The SICK logo is then followed by the initial screen.
3.
Confirm the initial screen with "OK". CLV Setup then checks whether a CLV is connected to the COM 1 port on the PC and whether the communication parameters on the PC match those on the CLV. If this is the case, the "Connected" status is displayed with the CLV specification in the bottom right corner of the screen, in the status bar. The detected CLV type is displayed in the toolbar in the DEVICE drop-down list (in this case: CLV 41x).
The software then loads the internal device description of the CLV and the defaults settings of the parameters/parameter values from its database and displays these on the tabs. The software then copies the current parameter set from the memory (RAM) of the CLV. This is displayed on the tabs instead of the default settings. You can edit the current parameter set on the tabs. The default values are displayed when the device is used for the first time. Troubleshooting If CLV Setup cannot establish communication, it displays "No connection" in the status bar on the bottom, right-hand side. There are two possible causes for this. Either the CLV is not connected or the communication parameters on the CLV do not match those on the PC. In this case, CLV Setup enters the CLV type of the device it last communicated with in the DEVICE drop-down list on the toolbar. The default setting is CLV 41x the first time CLV Setup is started. The software then loads the internal device description for this type and the default settings of the parameters/parameter values from its database and displays these on the tabs.
10-8
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 974/O079/01-09-2004
Page 99
Operating Instructions
Appendix
Chapter 10
CLV 41x bar code scanner
1.
Connect the PC to the host interface 2 of the CLV using a 3-core RS 232 data cable (null modem cable)(CDB 410 or CDM 410: connect the PC to the internal, 9-pin "Aux" plug). See Chapter 5.5.5 Connecting the PC to the host interface 2 (RS 232), Page 5-7.
2.
Click (AutoBaud detect) in the toolbar or choose OPTIONS, AUTOBAUD DETECT. CLV Setup scans the serial interface by varying the communication parameters and sends a telegram to the CLV repeatedly. CLV Setup resets temporarily the communication parameters in the CLV 41x to the default setting and indicates the change by outputting a message.
Fig. 10-5:
3.
Confirm the AUTO DETECT dialog window with "OK". As soon as a reply from the CLV is detected, CLV Setup conveys the values found for the communication parameters. Fig. 10-6 shows an example of the AUTOBAUD DETECT result display. CLV Setup displays "Connected" in the status bar on the bottom, righthand side.
Fig. 10-6:
8 009 974/O079/01-09-2004
CLV Setup: AutoBaud-Detect: Message about temporarily resetting the communcation parameters in the CLV 41x
CLV Setup: results of the AutoBaud detect function
4.
Confirm the AUTO DETECT dialog window with "OK". CLV Setup displays the detected CLV type in a separate dialog box and asks you whether you want to upload the current parameter set from the CLV.
5.
Confirm the dialog box with "Yes". CLV Setup then uploads the current parameter set from the RAM of the CLV to its database and displays the values on the tabs.
© SICK AG · Division Auto Ident · Germany · All rights reserved