Page 13
Operating Instructions
Notes on this document
Chapter 1
CLV 41x bar code scanner
1
Notes on this document 1.1
Function
This document contains instructions for operating the following bar code scanners: •
CLV 410 with fixed focus, standard range
•
CLV 412 with fixed focus, high density
•
CLV 414 with fixed focus, short range in the variants •
Line scanner without/with 105° angle attachment
•
Raster scanner without/with 105° angle attachment.
This document provides information on •
Installation and electrical connection
•
Startup
•
Operation and configuration (parameterizing)
•
Maintenance
•
Replacing the device while retaining the parameter set
•
Special applications and procedures.
The bar code scanners will all simply be called "CLV" below, except in such text passages where a differentiation is required.
1.2
Target audience
This document is intended for persons who are responsible for the following activities: 1.2.1
Installation, electrical connection, maintenance and replacement
Electricians and service technicians 1.2.2
Startup, operation and configuration
Technicians and engineers
1.3
Information content
This document contains all of the information required to install, make electrical connections and start up the CLV with the factory default settings. A series of step-by-step instructions is provided for each of these activities. The CLV is configured for specific applications using the Windows-based "CLV Setup" and "CLV Assistant". Further assistance is also available in the form of the online help system "CLV Setup Help". The procedure for installing and operating the user interface of the software is described in the Appendix. For further information on the design of the bar code scanner or on bar code technology in general, please contact the Auto Ident division at SICK AG. Internet address: www.sick.com.
8 009 974/O079/01-09-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
1-1
Page 14
Notes on this document
Chapter 1
Operating Instructions CLV 41x bar code scanner
1.4
Symbols used
Some of the information in this document is marked specially so that you can access it quickly: Warning Warnings are provided to prevent injury to operating personnel or serious damage to the bar code scanner. ¾
Note Explanation Recommendation
Always read warnings carefully and observe them at all times.
Notes indicate special features or characteristics. Explanations provide background information on technical correlations. Recommendations help you carry out certain procedures more effectively.
Tip
Tips explain settings in the user interface of the CLV Setup program.
Default setting
Marks a section containing the values of the factory default settings.
SCANNING FREQUENCY
This font indicates a term in the user interface of the CLV Setup program. Icons refer to buttons in the user interface of the CLV Setup program. This symbol identifies sections that describe steps carried out with the user interface of the CLV Setup program.
This symbol is used to mark sections that describe steps carried out with the profile programming.
This symbol refers to additional technical documentation.
1-2
¾
An action must be performed. This symbol identifies single-step instructions. Instructions consisting of several steps are numbered consecutively.
Ö
Here you select a function of the user interface of CLV Setup.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 974/O079/01-09-2004
Page 15
Safety information
Operating Instructions
Chapter 2
CLV 41x bar code scanner
2
Safety information 2.1
Authorized personnel
For the CLV to function correctly and safely, it must be installed and operated by sufficiently qualified personnel. The end user must be supplied with the operating instructions. The end user must be provided with expert tuition and is advised to read the operating instructions. The following qualifications are required for the various tasks involved: 2.1.1
Installation and maintenance
•
Practical basic technical training
•
Knowledge of the standard guidelines relating to safety in the workplace
2.1.2
Electrical connection and replacement
•
Practical training in electrical engineering
•
Knowledge of the standard safety guidelines relating to electrical engineering
•
Knowledge regarding the operation of the devices in the relevant application (e.g. conveyor belt)
2.1.3
Startup, operation and configuration
•
Knowledge regarding the operation of the devices in the relevant application (e.g. conveyor belt)
•
Knowledge of the software and hardware environment of the relevant application (e.g. conveyor belt)
•
Basic understanding of Windows 95TM/98TM, Windows NT4.0TM, Windows 2000TM or Windows XPTM
•
Basic understanding of an HTML browser (e.g. Internet ExplorerTM)
•
Basic understanding of data transfer methods
•
Basic understanding of bar code technology
2.2
Intended use
The CLV is designed to detect and decode bar codes automatically. It is installed in a reading station and reads bar codes on objects positioned on a conveyor belt, for example. The CLV transfers the data content of the decoded bar codes via its host interface to a host for further processing. Any warranty claims vis-à-vis SICK AG will be rendered invalid if the device is used for any other purpose or if changes are made to the device, including any made during the installation and electrical connection procedures. Note
8 009 974/O079/01-09-2004
Don’t open the device. The producer warranty will be forfeited if the device is opened.
© SICK AG · Division Auto Ident · Germany · All rights reserved
2-1
Page 16
Chapter 2
Safety information
Operating Instructions CLV 41x bar code scanner
2.3 ¾
General safety instructions and protection measures Carefully read the general safety instructions and observe them at all times. This also applies to the warnings provided for the activities described in each chapter of this document.
Risk of injury by electrical current In the CDM 410 Connection Module, the optional CMP 400 Power Supply Module is connected to a mains voltage of 100 to 250 V AC/ 50 Hz to 60 Hz. ¾
When working with electrical equipment, always follow the relevant safety regulations.
Laser radiation can seriously damage your eyesight. The CLV uses a class 2 red-light laser. Looking directly at the laser beam can seriously damage the retina in your eyes. The entire glass window acts as a laser outlet aperture. Caution – use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. ¾
As with sunlight, never look directly into the laser beam.
¾
Do not direct the laser beam at other persons.
¾
Mount and align the CLV in such a way to prevent the laser beam reflecting off mirrored surfaces.
¾
Do not open the housing. (Opening the housing does not deactivate the laser diode).
¾
Observe the laser protection specifications (latest version).
Laser power The laser operates at a wavelength of λ = 670 nm (visible red light). The power output of the laser beam at the reading window is max. 1.2 mW. The emitted beam is not dangerous to human skin. The product is classified in laser class 2 (laser class II) in accordance with EN 60825-1, IEC 60825-1, and 21 CFR 1040.10 (for publication date, see the warning sign on the device). Laser warnings The laser warning labels (Fig. 2-1) are attached at the following positions on the CLV:
2-2
•
The laser warning symbol and the laser warning in GB English/US English on line/raster scanners are positioned beside the reading window on the wide side of the device (Fig. 3-1, Page 3-5). The additional laser warnings in English applicable to the USA are positioned beside the reading window on the front side of the device and at the back end on the wide side.
•
The laser warning symbol and the laser warning in GB English/US English on line/raster scanners with a 105° angle attachment are positioned beside the reading window on the wide side (Fig. 3-1, Page 3-5). The additional laser warnings in English applicable to the USA are positioned on the back side of the attachment of the device and at the back end on the wide side.
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 974/O079/01-09-2004
Page 17
Safety information
Operating Instructions
Chapter 2
CLV 41x bar code scanner black-yellow signed on device:
black-silver signed on device:
Fig. 2-1:
Note
Laser warning labels found on the CLV
The device is supplied with an additional set of laser warning labels in German/US English and in French/US English. If necessary, these can be used to cover the GB English/ US English warning. If the CLV is installed in a machine/panel with the result that the laser warning labels are no longer visible, additional warnings (not included in the scope of delivery) must be provided on the machine beside the emergence aperture of the laser beam. Internal protective circuits
Explanation
The CLV is equipped with monitoring circuit-breakers that switch off the laser diode if problems arise with the laser beam. No maintenance required to keep this product in compliance with laser class II. Activation and deactivation of the laser diode when reading is controlled by the reading pulse (trigger source). A timer (laser timeout) automatically deactivates the laser diode 10 minutes (default setting) after a continuous reading pulse is initiated in reading mode with switching input pulse modes "Sensor Input" and "Serial Interface". In this case, the CLV outputs three consecutive tones via the beeper. The reading pulse interval is to be terminated by resetting the pulse signal. The laser diode is activated again by the next reading pulse. The laser timeout can be set in the range of 1 min to 25 h or deactivated (see Table 6-4, Page 6-9). In the "Percentage Evaluation" mode and "AutoSetup" mode as well as in the pulse modes "Free Running" and "Continuous Read", in reading mode, the laser diode is constantly activated. In the "reflector polling" trigger mode the laser diode is switched on for each 20th scan.
8 009 974/O079/01-09-2004
© SICK AG · Division Auto Ident · Germany · All rights reserved
2-3
Page 18
Chapter 2
Safety information
Operating Instructions CLV 41x bar code scanner
2.4
Quick stop and quick restart
2.4.1
Switching off the CLV
¾
Switch off the power supply or remove the CLV connector from the connection module.
This can result in loss of the following (at the most): • the application-specific parameter set, if it was only stored temporarily in the CLV
• the last reading result
• daily operating data (operating hours counter, trigger count, good read count)
2.4.2 ¾
Restarting the CLV
Switch on the supply voltage or reattach the CLV connector to the connection module. The CLV resumes operation with the parameter set that was last stored permanently and resets the daily operating data.
2.5
Environmental information
The CLV is designed to cause minimum impact on the environment. It does not contain any silicone-based materials on the housing surface and, therefore, does not represent any problems for e.g. paint sprayers in paint shops. 2.5.1
Power requirements
The power requirements are particularly low: • the CLV 410/412/414 scanners have a max. power consumption of 3 W
The value is given for devices with disconnected switching outputs. 2.5.2
Disposal after final decommissioning
Always dispose of unusable or irreparable devices in a manner that is not harmful to the environment and in accordance with the applicable national waste disposal regulations. The CLV can be separated into recyclable secondary raw materials and special-category waste (electronic scrap). See Chapter 7.3 Disposal, Page 7-2. At present, SICK AG does not accept any unusable or irreparable devices.
2-4
© SICK AG · Division Auto Ident · Germany · All rights reserved
8 009 974/O079/01-09-2004