The product reference guide for the Symbol MK1000 MicroKiosk. It covers the parts and features of the unit (function buttons, display, bar code scanning modes, memory and ports), mechanical setup for wired Ethernet, wireless Ethernet, RS-485 and RS-232 with AC or Power-over-Ethernet power, mounting and cable pin-outs, host communication setup through the PCK Configuration Menu, the System Menu or Telnet, the demo application and PCK emulation commands. Appendices hold programming bar codes, fonts, specifications and troubleshooting.
Its parts
- About This Guide
- About Your MK1000
- Setup and Installation: Mechanical
- Setup and Installation: Communication
- Software and Applications
- PCK Emulation
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
The Symbol MK1000 MicroKiosk Product Reference Guide, the full manual for installing, operating and programming the MK1000 in-store price verification kiosk in all its configurations. It covers the parts, scanning modes, display and memory, wired and wireless Ethernet, RS-485 and RS-232 setup, mounting, cable pin-outs, host configuration menus, PCK emulation, technical specifications and troubleshooting.
- Device
- In-store price verification kiosk with a scanner, a display for text and graphics and four programmable function buttons p. 17, 20
- Interface codes
- Model MK1000-xxx???xxxxx: RSE wired only (RS232, RS485, Ethernet); RFR wired, RF by PC Card; 2M1 or 2M5 2Mb radio (100mW or 500mW); 11M 11Mb radio; AL1, AL2, AL3 wired plus wireless p. 217
- Ports
- Power (2.0mm barrel jack, center positive), Com/Scanner (RJ-45, 10 conductor) and LAN (RJ-45) p. 27, 28
- Power
- 12-24VAC or 12-36VDC, 16VA, or Symbol Power-over-Ethernet (Bias-T); universal supply for 120V 60Hz, 230V 50Hz and 100V 50/60Hz p. 27, 28, 197
- Display
- Back lit 240 x 64 pixel LCD, white on blue, text and graphics, adjustable contrast p. 26
- Memory
- 1MB Flash for system firmware; 1MB SRAM for parameters, user programs and data p. 26, 27
- Scanner
- 650 ± 10 nm laser diode; 590-640 scans per second p. 197
- Symbologies
- UPC/EAN, Code 39, Interleaved 2 of 5, Code 128, Codabar, MSI, PDF417, RSS and Composite Codes p. 197
- Scan modes
- Cyclone omnidirectional 1D (factory default), Always Raster and Smart Raster p. 22
- Software
- Existing PCK91XX applications; IBM 4680/4690 terminal emulation; AirBEAM wireless configuration management; SDK available p. 198
- Com/Scanner port
- Serial link to a host or an external decoded or undecoded scanner; supplies +5V @ 500mA maximum on the RS-232 cable p. 27, 44
- RS-485 cable
- 1 twisted pair 26 AWG (7/34) tinned copper, foil wrapped, nominal impedance 120 ohms; network up to 4000 Ft. p. 34, 36
- Size and weight
- 11.4 in. H x 7.75 in. W x 4.25 in. D (max.), 29 cm H x 19.6 cm W x 10.8 cm D; 3 lbs./1.4 kg without cable p. 197
- Temperature
- Operating 0° C to 50° C (32° F to 122° F); storage -40 to +70 C p. 197
What this manual walks you through
- Setting up wired Ethernet with AC power or Power-over-Ethernet p. 30, 31
- Setting up wireless Ethernet with AC power or Power-over-Ethernet p. 32, 33
- Setting up an RS-485 network, including a host without RS-485 p. 34, 35, 36
- Setting up an RS-232 host connection p. 37
- Connecting an auxiliary scanner to the Com/Scanner port p. 38
- Mounting the MK1000 on a wall p. 39, 40
- Cable pin-outs for Ethernet, Power-over-Ethernet, RS-485, RS-232 and wand cables p. 41, 42, 43, 44, 45
- Changing the scanning mode p. 23
- Scanning PDF-417 and composite bar codes p. 24, 25
- Troubleshooting power, host polling, Ethernet links and firmware upgrades p. 199, 200, 201, 202, 203, 204, 205
Good to know
- Do not use Power-over-Ethernet together with an external power supply on the power port; the unit or network can be damaged. p. 31
- For RS-485 on the LAN port, only a 10-conductor RJ-45 plug can be used. p. 28
- An RS-232 to RS-485 conversion box must be sourced locally; it is not available from Symbol Technologies. p. 34
- A scan mode set by scanning a programming bar code lasts only until the unit is powered off. p. 23
- On RS-485, if the unit is not polled for one minute it shows a default Out of Service message. p. 200
Questions this manual answers
What power does the Symbol MK1000 need?
12-24VAC or 12-36VDC at 16VA from its power supply, or Power-over-Ethernet through a Bias-T module on the Ethernet cable. p. 28, 197
How do I tell which interfaces my MK1000 has?
Three letters or digits in the model number show it: for example RSE is wired only, 11M is the 11Mb radio only, and AL1 to AL3 have both. p. 217
How do I reset the MK1000 to factory defaults?
In the System menu, open System Configuration, then File/DBM, choose Delete Database, and exit the menu; most setup parameters return to factory defaults. p. 204
Why does my MK1000 keep rebooting during a firmware upgrade?
The unit does not have enough free memory. Delete the loaded files from the File/DBM screen in the System menu, then load the new firmware. p. 205
Can the MK1000 read PDF417 bar codes?
Yes, in the Always Raster or Smart Raster scan modes; the factory default Cyclone mode does not decode 2D codes like PDF. p. 22
Contents
Chapters and sections
Each line opens the PDF at its page.
- MK10001
- About This Guide11
- Chapter 1 About Your MK100017
- Chapter 2 Setup and Installation: Mechanical29
- Chapter 3 Setup and Installation: Communication47
- Chapter 4 Software and Applications113
- Chapter 5 PCK Emulation117
17 more lines, from page 126 on
- Display Commands126
- Appendix A Configuration Menu Programming Bar Codes137
- Appendix B PCK Configuration Programming Bar Codes145
- Appendix C Scanning Mode Programming Bar Codes187
- Appendix D MK1000 Fonts195
- Appendix E Technical Specifications197
- Appendix F Troubleshooting199
- Appendix G Table of MK1000 Communication Interfaces217
- Appendix H DHCP Options219
- Glossary223
- Index233
- Quick Startup Instructions240
The whole text · 28 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- MK10001-10
- About This Guide11-16
- Chapter 1 About Your MK100017-28
- Chapter 2 Setup and Installation: Mechanical, pages 29 to 3729-37
- Chapter 2 Setup and Installation: Mechanical, pages 38 to 4638-46
- Chapter 3 Setup and Installation: Communication, pages 47 to 5647-56
- Chapter 3 Setup and Installation: Communication, pages 57 to 6657-66
- Chapter 3 Setup and Installation: Communication, pages 67 to 7667-76
- Chapter 3 Setup and Installation: Communication, pages 77 to 8677-86
- Chapter 3 Setup and Installation: Communication, pages 87 to 9687-96
- Chapter 3 Setup and Installation: Communication, pages 97 to 10697-106
- Chapter 3 Setup and Installation: Communication, pages 107 to 112107-112
- Chapter 4 Software and Applications113-116
- Chapter 5 PCK Emulation, pages 117 to 126117-126
- Chapter 5 PCK Emulation, pages 127 to 136127-136
- Appendix A Configuration Menu Programming Bar Codes137-144
- Appendix B PCK Configuration Programming Bar Codes, pages 145 to 153145-153
- Appendix B PCK Configuration Programming Bar Codes, pages 154 to 162154-162
- Appendix B PCK Configuration Programming Bar Codes, pages 163 to 171163-171
- Appendix B PCK Configuration Programming Bar Codes, pages 172 to 180172-180
- Appendix B PCK Configuration Programming Bar Codes, pages 181 to 186181-186
- Appendix C Scanning Mode Programming Bar Codes187-194
- Pages 195 to 198195-198
- Appendix F Troubleshooting, pages 199 to 207199-207
- Appendix F Troubleshooting, pages 208 to 216208-216
- Pages 217 to 222217-222
- Glossary223-232
- Pages 233 to 240233-240