10.MK1000 will not communicate over a wiredEthernet connection.

Unit does not support a wired Ethernet connection.

1. Confirm your unit supports a wired Ethernet connection. - Find the model number (see sticker attached on the back of the unit). The model number structure is MK1000-xxx???xxxxx. To support a wired Ethernet connect, one of the following designations must be present: RSE, RFR, AL1, AL2 or AL3. (continued) 2. Determine the MK1000's IP Address. - Press the ‘4’ and ‘1’ buttons on the unit simultaneously (an Enter Password screen appears). - Type in ‘44213’ (System menu screen appears). - Scroll the cursor (<) down to Network by pressing the ‘3’ button. - With the cursor on Network, press ‘4’ (Network Configuration screen appears). - Scroll the cursor down to Ethernet by pressing ‘3’ twice. - With the cursor on Ethernet, press ‘4’ (Ethernet Configuration screen appears). - The 4th line shows the MK1000's wired IP Address - record it on a sheet of paper. - The factory default wired IP Address is 192.168.0.1.

F-10

Page 209

Troubleshooting

Table F-1. Troubleshooting (Continued) Problem (continued) MK1000 will not communicate over a wired-Ethernet connection.

Possible Causes

Possible Solutions 3. Confirm the Wired Ethernet Setup is ENABLED. - On the Ethernet Configuration screen (3rd line), Enabled must = Yes. - If Enabled = No, with the cursor on Enabled, press the ‘4’ button. Enabled should now = Yes. See Troubleshooting Note 1. - Press 1 (Network Configuration screen re-appears). (continued) 4. Confirm the Wireless (RF) Ethernet Setup is DISABLED. - Scroll the cursor down to Wired/ Wireless Ethernet by pressing ‘3’. - With the cursor on Wired/Wireless Ethernet, press ‘4’ (Wired/WIreless Configuration screen appears). - On the Wired/Wireless Configuration screen (3rd line), Enabled must = No. - If Enabled = Yes, with the cursor on Enabled, press the ‘4’ button. Enabled should now = No. See Troubleshooting Note 1. - Press ‘1’ (Network Configuration screen re-appears). - Press ‘1’ (System menu reappears).

F-11

Page 210

MK1000 MicroKiosk Product Reference Guide

Table F-1. Troubleshooting (Continued) Problem

Possible Causes

(continued) MK1000 will not communicate over a wired-Ethernet connection.

11.MK1000 will not communicate over a wireless-Ethernet connection.

F-12

Possible Solutions 5. Save ALL changes made and EXIT the System menu. - Scroll the cursor down to Save & Reboot by pressing the ‘3’ button three times. - With the cursor on Save & Reboot, press ‘4’. (System menu is exited, all change made are saved, and the unit reboots as described in Troubleshooting Note 1.)

Unit does not support a wireless Ethernet connection.

1. Confirm your unit supports a wireless (RF) Ethernet connection. - Find the model number (see sticker attached on the back of the unit). The model number structure is MK1000-xxx???xxxxx. To support a wireless Ethernet connect, one of the following designations must be present: 2M1, 2M5, 11M, AL1, AL2 or AL3.

Page 211

Troubleshooting

Table F-1. Troubleshooting (Continued) Problem (continued) MK1000 will not communicate over a wireless-Ethernet connection.

Possible Causes

Possible Solutions 2. Determine the MK1000's IP Address. - Press the ‘4’ and ‘1’ buttons on the unit simultaneously (an Enter Password screen appears). - Type in ‘44213’ (System menu appears). - Scroll the cursor (<) down to Network by pressing the ‘3’ button. - With the cursor on Network, press ‘4’ (Network Configuration screen appears). - Scroll the cursor down to Wired/ Wireless Ethernet by pressing the ‘3’ button three times. - With the cursor on Wired/Wireless Ethernet, press ‘4’ (Wired/Wireless Ethernet Configuration screen appears). - The 4th line shows the MK1000's wireless IP Address - record it on a sheet of paper. - The factory default wireless IP Address is 192.168.0.2. (continued)

F-13

Page 212

MK1000 MicroKiosk Product Reference Guide

Table F-1. Troubleshooting (Continued) Problem (continued) MK1000 will not communicate over a wireless-Ethernet connection.

F-14

Possible Causes

Possible Solutions 3. Confirm the Wireless (RF) Ethernet Setup is ENABLED. - On the Wired/Wireless Configuration screen (3rd line), Enabled must = Yes. - If Enabled = No, with the cursor on Enabled, press the ‘4’ button. Enabled should now = Yes. See Troubleshooting Note 1. - Press ‘1’ (Network Configuration screen re-appears). 4. Confirm the Wired Ethernet Setup is DISABLED. - Scroll the cursor up to Wired Ethernet by pressing ‘2’ - With the cursor on Wired Ethernet, press ‘4’ (Wired Ethernet Configuration screen appears). - On the Wried Ethernet Configuration screen (3rd line), Enabled must = No. - If Enabled = Yes, with the cursor on Enabled, press the ‘4’ button. Enabled should now = No. See Troubleshooting Note 1. - Press ‘1’ (Network Configuration screen re-appears). - Press ‘1’ (System menu screen reappears). (continued)

Page 213

Troubleshooting

Table F-1. Troubleshooting (Continued) Problem

Possible Causes

Possible Solutions

(continued) MK1000 will not communicate over a wireless-Ethernet connection.

5. Save ALL changes made and EXIT the System menu. - Scroll the cursor down to Save & Reboot by pressing the ‘3’ button three times. - With the cursor on Save & Reboot, press ‘4’ (System menu is exited, all changes made are saved, and the unit reboots as described in Troubleshooting Note 1.)

12. Parameter changes made to the MK1000 are not saved/ retained after exiting the menu screens.

The unit may have an INI type configuration file loaded in RAM. This static file is referenced to set certain parameters when the unit is powered up such as an IP Address. - Press the ‘4’ and ‘1’ buttons on the unit simultaneously (an Enter Password screen appears). - Type in ‘44213’ (System menu screen appears). - With the cursor (<) on System, press ‘4’ (System Configuration screen appears). - Scroll the cursor down to File/DBM by pressing the ‘3’ button three times. - With the cursor on File/DBM, press ‘4’ (File Sys/DBM Management screen appears). - With the cursor on Delete Files, press ‘4’ (any files loaded in RAM are deleted) and the unit automatically reboots itself. - The unit now saves and retains parameter changes.

F-15

Page 214

MK1000 MicroKiosk Product Reference Guide

Table F-1. Troubleshooting (Continued) Problem

Possible Causes

Possible Solutions

13. Bar code lookups with the host are timing out.

Heavy network traffic or Extend the Host time-out period from slow database response. the default value of 2000 milliseconds (2 seconds) to a maximum of 9900 milliseconds (9.9 seconds). Host time-out periods longer than 9900 milliseconds would indicate network or host unavailability, or a network or host failure.

14. Front panel buttons on the MK1000 are not working (disabled).

The MK1000 front panel buttons may have been disabled.

If the keypad is disabled, the MK1000 briefly displays "Keypad Disabled!" when the unit is rebooted or powered up. Keypad operation can be restored either through a Telnet session and accessing the "Drivers" menu, or by pressing and holding the ‘2’ and ‘3’ buttons simultaneously while the unit is booting up. Overriding the keypad setting in this manner causes the MK1000 to briefly display “Keypad Enabled.”