Page 199
Appendix F Troubleshooting Troubleshooting topics covered in this appendix include: 1. Unit does not turn on. 2. Unit does not respond to polls from the host computer (RS-485 only). 3. Unit does not send data to host computer (RS-232 only). 4. “Loader Activated...Stand By” message displays. 5. Determining the MK1000's current OS version. 6. Confirming communication with host computer. 7. Restoring factory default settings. 8. Unit does not complete firmware upgrade and keeps rebooting itself. 9. Determining the MK1000's IP Address. 10. Unit does not communicate over a wired-Ethernet connection. 11. Unit does not communicate over a wireless-Ethernet connection. 12. Parameter changes made to the MK1000 are not saved/retained after exiting the menu screens. 13. Bar code lookups with the host are timing out. 14. Front panel buttons on the MK1000 are not working (disabled).
F-1
Page 200
MK1000 MicroKiosk Product Reference Guide
Table F-1. Troubleshooting Problem 1. MK1000 does not turn on.
Possible Causes
Possible Solutions
No power to the device.
- Power via AC outlet - Check AC power to the device. Ensure power supply is plugged into AC power source and the MK1000. - Power via power-over-Ethernet - Confirm Ethernet cable is plugged into MK1000 LAN port. - Confirm other end of Ethernet cable is plugged into Bias-T (power-over-Ethernet). - Confirm Bias-T (power-overEthernet) module is plugged into an AC outlet. - Perform continuity check on Ethernet cable.
2. MK1000 does not respond to No communication polls from the host computer between the host and (RS-485 only). MK1000.
Check cabling to the MK1000. Ensure the MK1000 address is the same as the one you are polling. Note: When the MK1000 has not been polled for one minute, it displays a default “Out of Service” message (unless the default message was changed). Check polarity of signal at connection to network. Check communication parameters.
F-2
Page 201
Troubleshooting
Table F-1. Troubleshooting (Continued) Problem 3. MK1000 does not send data to host computer (RS-232 only).
Possible Causes
Possible Solutions
MK1000 is not Check setup communication programmed to work with parameters. the host. MK1000 is not connected Check cables to host computer. to the host.
4. “Loader Activated...Stand By” Embedded application message displays on the was disabled and no MK1000. custom application is loaded/available to run.
Either: 1) Return to the System menu and set the embedded apps option to enable. or 2) Load a custom application onto the MK1000.
5. How do I determine the MK1000's current OS version?
OS version is displayed on a screen within the System menu screens: - Press the ‘4’ and ‘1’ buttons on the unit simultaneously (an Enter Password screen appears). - Type in ‘44213’ (the System menu appears). - With the cursor (<) on System, press ‘4’ (System Configuration screen appears). - With the cursor on Info, press ‘4’ (System Information screen appears). - The OS Version is displayed on the 5th line of the screen. - If no Info option is available, the unit has OS version 4.06.05 or earlier. (continued)
(Not applicable)
F-3
Page 202
MK1000 MicroKiosk Product Reference Guide
Table F-1. Troubleshooting (Continued) Problem
Possible Causes
Possible Solutions
(continued) How do I determine the MK1000's current OS version?
To exit the System menu WITHOUT saving any changes: - Press ‘1’ (System Configuration screen appears). - Press ‘1’ (System menu appears). - Press ‘1’ (System menu is exited, changes are NOT saved, and the original settings are retained as described in Troubleshooting Note 1).
6. How do I confirm my MK1000 (Not applicable) is communicating with my host computer?
A PING command can be used to confirm ethernet communication between the host computer and MK1000. - From the Command / DOS prompt, type Ping followed by the MK1000 IP address, and then press Enter. The command looks like the following: "Ping 192.168.0.1". In this example, 192.168.0.1 is the MK1000's IP address. For instructions on how to determine your MK1000's IP address see the troubleshooting topic # 9. How do I determine the MK1000's IP Address? - A successful PING (proving communication exists) results in a message like, "reply from 192.168.0.1 ...". In addition, PING statistics will show packets sent to the MK1000 were RECEIVED. (continued)
F-4
Page 203
Troubleshooting
Table F-1. Troubleshooting (Continued) Problem (continued) How do I confirm my MK1000 is communicating with my host computer?
Possible Causes
Possible Solutions -
An unsuccessful PING (proving communication does not exist) results in a message like, "request timed out" or "Destination Host Unreachable". In addition, PING statistics will show packets sent to the MK1000 were LOST. - If communication does not exist between the MK1000 and host computer, examine the following: - Is the MK1000 receiving power? - Does your MK1000 support the type of Ethernet connection you are attempting to use? For example, if trying to communicate via a cabled connection, confirm your unit supports wired Ethernet communication. - Is the MK1000 properly configured for the type of Ethernet communication you are using (wired-cabled vs. wireless-RF)? - For wired Ethernet connections, is the Ethernet cable properly connected? - Are you trying to communicate with the correct MK1000 IP address?
F-5
Page 204
MK1000 MicroKiosk Product Reference Guide
Table F-1. Troubleshooting (Continued) Problem
Possible Causes
7. How do I return the MK1000 (Not applicable) to its factory default settings?
F-6
Possible Solutions The majority of MK1000 setup parameters can be returned to their factory defaults from a screen within the System menu. - Press the ‘4’ and ‘1’ buttons on the unit simultaneously (an Enter Password screen appears). - Type in ‘44213’ (System menu screen appears). - With the cursor (<) on System, press ‘4’ (System Configuration screen appears). - Scroll the cursor down to File/DBM by pressing the ‘3’ button three times. - With the cursor on File/DBM, press ‘4’ (File Sys/DBM Management screen appears). - Scroll the cursor down to Delete Database by pressing ‘3’. - With the cursor on Delete Database, press ‘4’. The database of modified setup parameters is automatically deleted. Upon exiting the System menu, the unit defaults to its factory settings database. See Troubleshooting Note 1. - Press ‘1’ (System Configuration screen re-appears). - Press ‘1’ (System menu reappears). (continued)
Page 205
Troubleshooting
Table F-1. Troubleshooting (Continued) Problem
Possible Causes
(continued) How do I return the MK1000 to its factory default settings?
8. My MK1000 does not complete the firmware upgrade process. It keeps rebooting itself.
Possible Solutions Save ALL changes made and EXIT the System menu. - Scroll the cursor down to Save & Reboot by pressing the ‘3’ button four times. - With the cursor on Save & Reboot, press ‘4’. (System menu is exited, all changes made are saved, and the unit reboots as described in Troubleshooting Note 1.)
The unit does not have enough free memory available.
The unit does not have enough free memory available. - While stuck in the rebooting loop, press the ‘4’ and ‘1’ buttons on the unit simultaneously (an Enter Password screen appears). - Type in ‘44213’ (System menu screen appears). - With the cursor (<) on System, press ‘4’ (System Configuration screen appears). - Scroll the cursor down to File/DBM by pressing the ‘3’ button three times. - With the cursor on File/DBM, press ‘4’ (File Sys/DBM Management screen appears). - With the cursor on Delete Files, press ‘4’ (any files loaded in RAM are deleted) and the unit automatically reboots itself. - The unit is now ready for new firmware to be loaded.
F-7
Page 206
MK1000 MicroKiosk Product Reference Guide
Table F-1. Troubleshooting (Continued) Problem 9. How do I determine the MK1000's IP Address?
F-8
Possible Causes (Not applicable)
Possible Solutions Wired Ethernet Connection - Press the ‘4’ and ‘1’ buttons on the unit simultaneously (an Enter Password screen appears). - Type in ‘44213’ (System menu appears). - Scroll the cursor (<) down to Network by pressing the ‘3’ button. - With the cursor on Network, press ‘4’ (Network Configuration menu appears). - Scroll the cursor down to Ethernet by pressing ‘3’ twice. - With the cursor on Ethernet, press’ 4’ (Ethernet Configuration screen appears). - The 4th line shows MK1000's wired IP Address - record it on a sheet of paper. - The factory default wired IP Address is 192.168.0.1. - To exit the System menu WITHOUT saving/making any changes... - Press the 1 button - three times (continued)
Page 207
Troubleshooting
Table F-1. Troubleshooting (Continued) Problem (continued) How do I determine the MK1000's IP Address?
Possible Causes
Possible Solutions Wireless (RF) Ethernet Connection - Press the ‘4’ and ‘1’ buttons on the unit simultaneously (an Enter Password screen appears). - Type in ‘44213’ (System menu appears). - Scroll the cursor (<) down to Network by pressing the ‘3’ button. - With the cursor on Network, press ‘4’ (Network Configuration screen appears). - Scroll the cursor down to Wired/ Wireless Ethernet by pressing the ‘3’ button three times. - With the cursor on Wired/Wireless Ethernet, press ‘4’ (Wired/Wireless Ethernet Configuration screen appears). - The 4th line shows the MK1000's wireless IP Address - record it on a sheet of paper. - The factory default wireless IP Address is 192.168.0.2. - To exit the System menu WITHOUT saving/making any changes - Press the ‘1’ button three times.
F-9