The text of a manual · part 9 of 28
MK1000 MicroKiosk Product Reference Guide: Chapter 3 Setup and Installation: Communication, pages 77 to 86
Pages 77 to 86 of 240, from MK1000 MicroKiosk Product Reference Guide
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MK-1000
Page 77
Setup and Installation: Communication
2. Press the Previous or Next buttons to move the "<" cursor to the Save & Reboot option. 3. Press the Enter button to save changes and reboot.
Entering Alphanumeric Values To enter alphanumeric values when you want to change the contents of a field, such as an IP address: 1. Select the field using Previous and Next buttons. 2. Press the Enter button (i.e., button ‘4’) to enter "scroll-edit" mode. The field clears, and the first character of the field displays. For instance, when changing an IP address, the field is cleared and a zero ("0") displays at the first position with a blinking line under it. 3. Press the Previous and Next buttons to rotate through all possible values (0-9, "."). 4. When you reach the desired value, press the Enter button to lock it in and move to the next position. 5. If the desired value is entered into a position and you are finished data entry, press the Escape button to leave scroll-edit mode. 6. Press Enter to make the change permanent. The "<" cursor points to the field you just changed. 7. Press the Escape button to return to the main menu. 8. Select Save & Reboot to save your changes. Note: If you enter an incorrect value in a numeric data field (e.g., IP address) and want to start over, press the ‘1’ button (Escape) twice to replace the original data.
The System Configuration Menu From the System menu (see Figure 3-26 on page 3-26), press the Previous or Next buttons to move the "<" cursor to the System option and press the Enter button.
3-31
Page 78
MK1000 MicroKiosk Product Reference Guide
The System Configuration menu displays:
System Configuration Info < File/DBM Passwords Unit Settings Debug Mode : DISABLED Embedded Apps: ENABLED Display System Info Figure 3-29. System Configuration Menu Table 3-5. System Configuration Menu Definitions Field Name
3-32
Description
Info
When selected, the Info option displays the System Information screen (see Figure 3-30). This screen displays the boot part number, boot version, operating system part number, the operating system version, application part number, and the application version.
File/DBM
When selected, the File/DBM option displays the File Sys/DBM Management screen (see Figure 331). From this screen it is possible to delete files located in RAM, or delete database memory which constitutes user stored values in the system DBM or GL. Deleting the database also returns all driver configuration settings to their defaults.
Passwords
When selected, the Passwords option displays the Change Passwords screen (see Figure 3-32). From this screen you can set and change the FTP/ Telnet and keypad passwords.
Unit Settings
When selected, the Unit Setting option displays the Unit Settings screen (see Figure 3-33). From this screen you can change the unit’s serial number and ID.
Page 79
Setup and Installation: Communication
Table 3-5. System Configuration Menu Definitions (Continued) Field Name Debug Mode
Description The Debug option can be used by programmers to allow dumping output from their programs to either a Serial port, or through a Telnet connection. If Serial port is selected, the output goes to the Com/ Scanner port. (For programmer's, that's C_SID_IO_UART1.) While debugging using the Serial port, that port cannot be used by the user's application for any other purpose. The default Debug Mode for the MK1000 is DISABLED.
Embedded Apps
Toggle this field by pressing the Enter button. Enabling Embedded Apps allows the PCK emulation to run or, if configured, the built in Demo and Factory Test programs. Disabling Embedded Apps allows a downloaded user application to operate without interference from any application programs that are embedded. The default Embedded Apps value for the MK1000 is ENABLED.
3-33
Page 80
MK1000 MicroKiosk Product Reference Guide
System Information Screen From the System Configuration menu (see Figure 3-29 on page 3-32), press the Previous or Next buttons to move the "<" cursor to the Info option and press the Enter button. To return to the System Configuration menu, press the ‘1’ button to escape. The System Information screen displays:
System Information Boot P/N : S-14-00D-0N-09 Boot Vers: V01.12.09 OS P/N : S-14-001-11-03 OS Vers : V4.09.00 APP P/N : S-15-016-02-0L APP Vers : V1.09.00
Figure 3-30. System Information Screen Table 3-6. System Information Screen Definitions Field Name
3-34
Description
Boot P/N
This field represents the CTC boot block part number. The default Boot P/N for the MK1000 is S-14-00D-0N-09.
Boot Vers
The MK1000 boot block version number is V01.12.09.
OS P/N
This field represents the CTC operating system part number. The default OS P/N for the MK1000 is S-14-001-11-0Fx.
OS Vers
The MK1000 OS (firmware) version number is V4.06.08.
APP P/N
This field represents the embedded application part number. The default APP P/N for the MK1000 is S-15-016-02-xx (where xx is the revision level).
Page 81
Setup and Installation: Communication
Table 3-6. System Information Screen Definitions (Continued) Field Name APP Vers
Description The PCK application version number.
File Sys/DBM Management Screen From the System Configuration menu (see Figure 3-29 on page 3-32), press the Previous or Next buttons to move the "<" cursor to the File/DBM option and press the Enter button. To return to the System Configuration menu, press the ‘1’ button to escape. The File Sys/DBM Management screen displays:
File/DBM Management Delete Files < Delete Database
Delete All RAM Files & Reboot Figure 3-31. File Sys/DBM Management Screen Table 3-7. File Sys/DBM Management Screen Definitions Field Name
Description
Delete Files
When this option is selected, all files in RAM are deleted and the MK1000 reboots. This option must be executed before loading new firmware (OS), if an upgraded version of the PCK emulation application was loaded.
Delete Database
When this option is selected, the database of modified MK1000 setup parameters is deleted.
3-35
Page 82
MK1000 MicroKiosk Product Reference Guide
Change Passwords Screen From the System Configuration menu (see Figure 3-29 on page 3-32), press the Previous or Next buttons to move the "<" cursor to the Passwords option and press the Enter button. To return to the System Configuration menu, press the ‘1’ button to escape. The Change Passwords screen displays:
Change Passwords FTP/Telnet Password: < Keypad Password:
Set Telnet/FTP Password Figure 3-32. Change Passwords Screen Table 3-8. Change Passwords Screen Definitions Field Name
3-36
Description
FTP/Telnet Password
Press the Previous or Next buttons to move the "<" cursor to this field and enter the password required for FTP/Telnet operation.
Keypad Password
Press the Previous or Next buttons to move the "<" cursor to this field and enter the password required for user keypad operation.
Page 83
Setup and Installation: Communication
Change Unit Settings Screen From the System Configuration menu (see Figure 3-29 on page 3-32), press the Previous or Next buttons to move the "<" cursor to the Unit Settings option and press the Enter button. To return to the System Configuration menu, press the ‘1’ button to escape. The Unit Settings screen displays:
Unit Settings: Serial#: 01289AL051 Unit ID: 5
Figure 3-33. Unit Settings Screen Table 3-9. Unit Settings Screen Definitions Field Name
Description
Serial#
This is a read only field that includes the unit’s serial number.
Unit ID
This is a read only field that includes an identification number for the unit.
3-37
Page 84
MK1000 MicroKiosk Product Reference Guide
The Network Configuration Menu From the System menu (see Figure 3-26 on page 3-26), press the Previous or Next buttons to move the "<" cursor to the Network option and press the Enter button. The Network Configuration menu displays:
Network Configuration TCP/IP < Server Wired Ethernet Wireless Ethernet TFTP Configure TCP/IP Figure 3-34. Network Configuration Menu Note: If DHCP mode is disabled and the IP address for either Wired Ethernet or Wireless Ethernet is set to 0.0.0.0 (all zeros), then that interface attempts a BOOTP operation to obtain its IP address, Netmask and Gateway IP. Once a DHCP or BOOTP operation is successfully performed, the appropriate fields for the requesting device are filled in with the obtained values.
3-38
Page 85
Setup and Installation: Communication
Table 3-10. Network Configuration Menu Definitions Field Name TCP/IP
Description When selected, the TCP/IP option displays the TCP/IP Configuration screen (see Figure 3-35). From this screen it is possible to configure the primary interface (Wired Ethernet or Wireless Ethernet) that is used for establishing a TCP/UDP/ IP connection and enabling DHCP mode. The primary interface is the first device that is started when the protocol stack begins operation. If both devices are enabled and both have the same subnet, outgoing communications are sent out by the primary interface even though the incoming packets may have arrived on the secondary interface. Therefore, it is necessary to ensure that the two interfaces are not setup on the same subnet. Configuring DHCP mode enables DHCP upon startup for either or both interfaces, if enabled. (For a list of MK1000 supported
DHCP options, see Appendix H, DHCP Options.)
Server
When selected, the Server option displays the Server Configuration screen (see Figure 3-38).The fields on this screen can be used to provide information to an application running on the MK1000. Configurable items on this screen are Server IP, Server Port and Server Name.
Wired Ethernet
When selected, the Wired Ethernet option displays the Wired Ethernet Configuration screen (see Figure 3-39). This screen allows configuration of the Wired Ethernet port. The port can be enabled or disabled, if not being used. Also on this screen the user can modify the IP address associated with this port along with the Netmask (i.e., Subnet Mask) and default Gateway IP addresses.
3-39
Page 86
MK1000 MicroKiosk Product Reference Guide
Table 3-10. Network Configuration Menu Definitions (Continued) Field Name
Description
Wireless Ethernet
When selected, the Wireless Ethernet option displays the Wireless Ethernet Configuration screen for RF Settings (see Figure 3-41). The configuration screen for the Wireless Ethernet is nearly identical in function to that of the Wired Ethernet port. The MAC address of the radio (if present) is displayed at the top of the configuration screen (also factory assigned). Also on this screen is a link to RF Settings (see Figure 3-41) that allows configuration of Wireless Ethernet specific parameters such as ESS ID, Encryption type, Key ID and Key Management. From the Key Management screen it is possible to enter the various key (button) values in Hexadecimal form.
TFTP
Not implemented. In the future, this option will be used to specify a host system from which OS firmware updates may be obtained.
TCP/IP Configuration Screen From the Network Configuration menu (see Figure 3-34 on page 3-38), press the Previous or Next buttons to move the "<" cursor to the TCP/IP option and press the Enter button. To return to the Network Configuration menu, press the ‘1’ button to escape. The TCP/IP Configuration screen displays:
TCP/IP Configuration Interface: WIRELESS ETHERNET < DHCP: DISABLED DHCP Setup: Domain Setup
Select Wired or Wireless Figure 3-35. TCP/IP Configuration Screen
3-40