Page 67
Setup and Installation: Communication
To enter changes on each screen, scan the required numeric bar code(s) to enter data in any field, as necessary. (Refer to the TCP/IP Configuration section for each screen.) For Host IP addresses, you must enter three digits for each segment for "dots" to be supplied correctly. For example, if you want to set the address 10.10.1.2, you must enter 010.010.001.002. Remember to scan the Save & Exit bar code when you are finished, or scan Cancel to escape WITHOUT completing the entry. Note: You must scan Cancel two times to escape WITHOUT completing the entry. The first scan erases the data and the second scan escapes to the previous screen WITHOUT completing the entry.
RS-232/RS-485 Configuration When Change Host Config is selected at the PCK Configuration menu, the system automatically displays the current host type. If RS-232 or RS-485 is the current host type, the appropriate screen displays for configuration. Refer to the section Auxiliary Port Parameters for RS-232 and RS-485 configuration information.
Auxiliary Port Parameters Edit Aux Port Params - PCK Configuration Menu Option 4 To select or change the auxiliary port parameters, choose Edit Aux Port Params at the PCK Configuration menu by scanning the "4" bar code located in the section Numeric Bar Codes beginning on page B-6. The following RS-232 Configuration screen displays (RS-485 Configuration for an RS-485 host type):
RS-232 Configuration 1. Baud: 19200 2. Data Bits: 8 3. Stop Bits: 1 4. Parity: None 5. Flow Cntrl: DTR/DSR Scan Item Number to Edit Figure 3-20. RS-232 Configuration Screen
3-21
Page 68
MK1000 MicroKiosk Product Reference Guide
Scan the number “1”, "2", “3”, “4”, or “5” bar code to display the appropriate screen to change the Baud Rate, Data Bits, Stop Bits, Parity, or Flow Control respectively. (RS-485 Configuration includes an additional option, ‘6. Net ID’.) Note: When you have completed entering numeric values on any screen, scan the "Enter" bar code. Successive scans of the "Enter" bar code return you to the main PCK Configuration menu where you must scan "Exit PCK Config" to save changes. If you wish to exit any screen without completing your entries, scan the Cancel bar code to return to the parent screen. Any changes made in the present screen are discarded.
Selecting a Baud When Baud is selected at the RS-232/RS-485 Configuration screen by scanning the “1” bar code located in the section Numeric Bar Codes beginning on page B-6, the following screen displays:
Current Baud: 19200 Select New Baud: 1. 1200 2. 2400 3. 4800 4. 9600 5. 14400 6. 19200 Figure 3-21. Baud Rate Screen To select or change the baud rate, Scan the required numeric bar code(s) to select the new baud. Remember to scan the Save & Exit bar code when you are finished, or scan Cancel to escape WITHOUT completing the entry.
3-22
Page 69
Setup and Installation: Communication
Selecting Data Bits When Data Bits is selected at the RS-232/RS-485 Configuration screen by scanning the “2” bar code located in the section Numeric Bar Codes beginning on page B-6, the following screen displays:
Current Data Bits: 8 New Data Bits:
Figure 3-22. Data Bits Screen Scan the required numeric bar code(s) to enter the new data bits value. Remember to scan the Save & Exit bar code when you are finished, or scan Cancel to escape WITHOUT completing the entry.
Selecting Stopbits When Stop Bits is selected at the RS-232/RS-485 Configuration screen by scanning the “3” bar code located in the section Numeric Bar Codes beginning on page B-6, the following screen displays:
Current Stopbits: 1 New Stopbits:
Scan number of stop bits Figure 3-23. Stopbits Screen Scan the required numeric bar code(s) to enter the new stopbits value. Remember to scan the Save & Exit bar code when you are finished, or scan Cancel to escape WITHOUT completing the entry. 3-23
Page 70
MK1000 MicroKiosk Product Reference Guide
Selecting Parity When Parity is selected at the RS-232/RS-485 Configuration screen by scanning the “4” bar code located in the section Numeric Bar Codes beginning on page B-6, the following screen displays:
Current Parity:
None
Select New Parity: 1. None 2. Odd 3. Even Scan 1-3 to select parity Figure 3-24. Parity Screen Scan the required numeric bar code(s) to select the new parity. Remember to scan the Save & Exit bar code when you are finished, or scan Cancel to escape WITHOUT completing the entry.
Selecting Flow Control When Flow Cntrl is selected at the RS-232/RS-485 Configuration screen by scanning the “5” bar code located in the section Numeric Bar Codes beginning on page B-6, the following screen displays:
Current Flow Control:
DTR/DSR
Select New Flow Control 1. None 2. XON/XOFF 3. DTR/DSR Scan 1-3 to select Flow Ctrl Figure 3-25. Flow Control Screen Scan the required numeric bar code(s) to select the new flow control. Remember to scan the Save & Exit bar code when you are finished, or scan Cancel to escape WITHOUT completing the entry. 3-24
Page 71
Setup and Installation: Communication
Configuring via the System Menu Overview The MK1000 can be configured for operation with PCK based applications using the System menu. In addition, if running a custom application not based on PCK emulation, the System menu is the only method for configuring the unit. The System menu can be accessed locally using the MK1000 function buttons, locally by scanning programming bar codes, or remotely via a Telnet client. From the System menu all MK1000 parameters can be accessed except the PCK communication interface (Change/Select Host Type), software handshaking, and RS-485 Net ID. These parameters can only be accessed from the PCK Configuration menu. For information on alternate methods of configuring the MK1000, see page 3-3.
3-25
Page 72
MK1000 MicroKiosk Product Reference Guide
MAP: System Menu Upon entering the menu system, Figure 3-26 is used for navigation.
Figure 3-26. System Menus/Screens 3-26
Page 73
Setup and Installation: Communication
Entering, Navigating & Saving Changes Entering the System Menu There are three ways to access the System menu: • locally using the MK1000 function buttons
• locally by scanning bar codes
• remotely via Telnet. Note: The PCK Configuration and MK1000 System menus cannot be accessed simultaneously. Only one menu can be active at a time.
For information about accessing Configuration menus/screens remotely via Telnet, refer to Configuration via a Telnet Session on page 3-63. To use the MK1000 function buttons to access the first configuration menu: 1. Press the '1' and '4' buttons simultaneously to display the Password screen.
Enter Password:
Figure 3-27. Password Screen 2. Using the four function buttons, enter the password '44213'. Note: If you enter the wrong 5-digit password, the system returns to the Out of Service screen. Press the '1' and '4' buttons simultaneously to start over. If you enter less than 5-digits and want to start over, enter five random digits to fill the buffer and return to the Out of Service screen.
3-27
Page 74
MK1000 MicroKiosk Product Reference Guide
3. When the password is entered successfully, the System menu displays:
System Menu System < Network Drivers User Save & Reboot Set System Configuration Figure 3-28. System Menu When the System menu displays, other system activity related to application programs is suspended. Also, while the menus and screens are active, a time-out mechanism is in effect. If no button is pressed for two minutes, the menu system automatically terminates and resumes the application process(es) that was/were previously active.
Navigating the System Menu The MK1000 has four function buttons located on the front panel. (See Parts of the MK1000 on page 1-3 for button locations.) These buttons can be used to navigate the configuration menu and configure system parameters. Note: In addition to the four function buttons, the bar codes in Appendix A, Configuration Menu Programming Bar Codes can be used for menu navigation.
3-28
Page 75
Setup and Installation: Communication
The use of the four buttons are described below. Table 3-3. Navigating The Configuration Menus/Screens Using Function Buttons Button
Button Use
Description
Button 1
Escape
Returns to the previous screen.
Button 2
Previous
Moves the cursor (designated by the “<“ symbol) up to any selectable menu item or alterable field.
Button 3
Next
Moves the cursor (designated by the “<“ symbol) down to any selectable menu item or alterable field.
Button 4
Enter
Activates the selection to which the arrow (designated by the < symbol) points. In the case of editable fields, pressing Enter may change a value to one of several in a list or may enter a scrolling-edit mode where the user may enter multiple characters and or digits to complete the field edit.
In addition to the button functions described in Table 3-3, the buttons also allow you to enter alphanumeric values in data entry fields on the configuration screens. For more information, refer to Entering Alphanumeric Values.
Disabling & Enabling Function Buttons Disabling and enabling function buttons is managed from the Driver Configuration menu (see page 3-53). When the keypad is “Enabled" (default state), the keypad buttons function as noted in Table 3-3. When the keypad is “Disabled”, it can no longer be used to access any of the MK1000 menus. Once disabled, the keypad can be restored either through a Telnet session and accessing the "Drivers" menu, or by pressing and holding the ‘4’ button while the unit is booting up.
3-29
Page 76
MK1000 MicroKiosk Product Reference Guide
Programming Function Buttons Function buttons cannot be programmed however, the PCK application sends a message to the host whenever a button is pressed. Button 1 sends "BTN1", Button 2 sends "BTN2", etc. No provision exists within the PCK application to query what is currently displayed (i.e., to track which screen is displayed) when using multiple screens. To do this, developers must devise their own method for establishing a default screen environment and provide a way to restore the defaults and appropriate screen sequences based on current system events (button press, bar code scan, host connect/disconnect etc.). The PCK specification currently recognizes four unique events and has default screens (messages) for each of those events. (Also see Table 5-4 on page 5-10 for information about Command Parameters.) Table 3-4. Events & Screen Messages Message ID
Event
999
Lost Host Connection message
1000
Power up message
1001
Out of Service message
1002
Ready to Scan message.
All other messages (screens) are host driven, including scanner and button responses. The developer should be able to track what is displayed because the host application drives the screen content.
Saving Changes Exiting the System menu via the Save & Reboot option saves any changes made. Changes made while navigating the System menu screens are NOT saved or applied UNLESS the System menu is exited through its Save & Reboot option. Upon exiting in this manner, the unit reboots and applies the changes. If the System menu is exited by pressing the ‘1’ button (Escape), changes will NOT be saved and the original settings are retained. To save changes: 1. Access the System menu.