Page 107
Setup and Installation: Communication
Table 3-22. RS-485 Config Screen Definitions (Continued) Field Name Rx (Mode)
Description Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Rx Mode. The default Rx Mode setting for MK1000 RS-485 port settings is XPT. Available Rx Mode settings: PRTR, CMDL, or XPT.
The User Configuration Menu The User Configuration menu is used to change PCK application parameters using the MK1000 function buttons, or remotely through Telnet. From the System menu (see Figure 3-26 on page 3-26), press the Previous or Next buttons to move the "<" cursor to the User option and press the Enter button. The User Configuration menu displays:
User Configuration Host Type : RS-232 Host Timeout : 2000 Turnaround Time : 25 S/W Handshaking : ACK/NAK RS-485 ID : 48
Figure 3-48. User Configuration Menu
3-61
Page 108
MK1000 MicroKiosk Product Reference Guide
Table 3-23. User Configuration Menu Definitions Field Name
3-62
Description
Host Type
Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Host Type. The Host Type setting on this screen defaults to the current host type setting for the MK1000. Available Host Type settings: TCP/IP, UDP/IP, RS232 and RS-485.
Host Time-out
Press the Previous or Next buttons to move the "<" cursor to this field and enter the Host Time-out period. The time-out period determines the maximum time allowed to elapse before the MK1000 assumes end of transmission. The delay period can range from 100 to 9900 msecs in 100 msec increments. The default Host Time-out period is 2000 msecs.
Turnaround Time
Press the Previous or Next buttons to move the "<" cursor to this field and enter the Turnaround Time. The turnaround time is the time period that the host or MK1000 waits before sending a response. The turnaround time can range from 5 to 255 msecs. The default Turnaround Time for the MK1000 is 25 msecs.
S/W Handshaking
Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the type of Software Handshaking. Available Software Handshaking types: NONE, ACK/NAK, ENQ, ACK/NAK/ENQ and RAW. The default S/W Handshaking type for the MK1000 is ACK/NAK.
RS-485 ID
Press the Previous or Next buttons to move the "<" cursor to this field and enter the RS-485 ID. The default RS-485 ID for the MK1000 is 48.
Page 109
Setup and Installation: Communication
Configuration via a Telnet Session Overview A Telnet client can be used to remotely connect to the MK1000 and remotely access the System menu. And, as mentioned in the System menu overview, the System menu is used to configure the unit for operation with PCK based applications. The System menu can also be used to configure the unit for operation with a custom application not based on PCK emulation. From the System menu, all MK1000 parameters can be accessed except the PCK communication interface (Change/Select Host Type), software handshaking, and RS-485 Net ID. These parameters can only be accessed from the PCK Configuration menu. For information on alternate methods of configuring the MK1000, see page 3-3.
MAP: Telnet Menu Upon initiating the Telnet session, screens appear as they do when navigating the System menu as shown on page 3-25. Depending on the version of software installed, a Telnet Session menu with Debug and Configuration options may appear. If this menu displays, select the Configuration option (option 2) and press enter.
3-63
Page 110
MK1000 MicroKiosk Product Reference Guide
Entering, Navigating & Saving Changes Entering the Telnet Session To a initiate a Telnet session with the MK1000 from a computer running a Window's operating system, type the following command (using your MK1000’s IP address) from a DOS/Command prompt and press Enter: telnet 192.168.0.1 In the example above, 192.168.0.1 represents the MK1000's IP address. If you need assistance determining your MK1000’s IP address see the troubleshooting section. Next, you may be asked to “ENTER PASSWORD”. Type in ‘44213’ and press Enter*. Note while typing in the password, the cursor remains stationary while continuing to blink. *Some Telnet clients may require a simultaneous Ctrl Enter.
Navigating the Telnet Menu To navigate within the Telnet session, use the following buttons. Table 3-24. Telnet Navigation Buttons Button
Description - Moves the cursor up.
- Moves the cursor down.
3-64
Enter
- Selects the highlighted item. - Enters a value that has been typed in.
Esc
- Exits the current screen and returns to the previously displayed screen. - Escapes a data entry field.
Ctrl-D
Exits the Telnet session, WITHOUT saving any changes.
Page 111
Setup and Installation: Communication
To properly navigate the System menu screens, the Telnet client must be configured to Keyboard Mapping = VT100 / ANSI terminal emulation. If running a Telnet session from a laptop, you may need to turn off the "Num Lock" key.
Saving Changes and Exiting the Telnet Session After you have navigated through the necessary screens and made your desired changes, you can save these changes by highlighting the "Save & Reboot" option from the System menu and then pressing the Enter key.
3-65
Page 112
MK1000 MicroKiosk Product Reference Guide
3-66