Page 97

Setup and Installation: Communication

Table 3-17. Radio Status Screen Definitions (Continued) Field Name

Description

Note: All fields on this screen are read only. Port

This field includes the Port number selected by the AP for RF communications. This value can be Err (Wireless Networking not selected or not enabled), SEARCHING (AP not associated) or CONN_ESS (AP associated). If the TCP/IP interface is not set to "Wireless Ethernet" and the Wireless Ethernet Configuration is not set to "Enabled" prior to powering up the MK1000, the value in this field is Err. This field is read only.

CQ

This field includes the Channel Quality of current RF communications. The higher the value, the better the channel quality. If the TCP/IP interface is not set to "Wireless Ethernet" and the Wireless Ethernet Configuration is not set to "Enabled" prior to powering up the MK1000, the value in this field is 0. This field is read only.

ASL (Average Signal Level)

This field includes the RF signal quality. The higher the value, the better the signal quality. If the TCP/IP interface is not set to "Wireless Ethernet" and the Wireless Ethernet Configuration is not set to "Enabled" prior to powering up the MK1000, the value in this field is 0. This field is read only.

ANL (Average Noise Level)

This field includes the RF signal noise level. The lower the value, the better the signal quality. If the TCP/IP interface is not set to "Wireless Ethernet" and the Wireless Ethernet Configuration is not set to "Enabled" prior to powering up the MK1000, the value in this field is 0. This field is read only.

3-51

Page 98

MK1000 MicroKiosk Product Reference Guide

TFTP Configuration Screen From the Network Configuration menu (see Figure 3-34 on page 3-38), press the Previous or Next buttons to move the "<" cursor to the TFTP option and press the Enter button. To return to the Network Configuration menu, press the ‘1’ button to escape. The TFTP Configuration screen displays:

TFTP Configuration TFTP IP: 0.0.0.0 < TFTP Server: File Name:

Set TFTP IP Address Figure 3-43. TFTP Configuration Screen

Table 3-18. TFTP Configuration Screen Definitions Field Name

3-52

Description

TFTP IP

Press the Previous or Next buttons to move the "<" cursor to this field to enter the TFTP IP address. The default TFTP IP address for the MK1000 is ‘no address’ (all zeros).

TFTP Server

Press the Previous or Next buttons to move the "<" cursor to this field to enter the TFTP server name.

File Name

Press the Previous or Next buttons to move the "<" cursor to this field to enter the TFTP file name.

Page 99

Setup and Installation: Communication

The Driver Configuration Menu From the System menu (see Figure 3-26 on page 3-26), press the Previous or Next buttons to move the "<" cursor to the Drivers option and press the Enter button. The Driver Configuration menu displays:

Driver Configuration Internal Scanner < External/Aux Barcode Reader RS-232 Port RS-485 Port KEYPAD: ENABLED Configure Laser Scanner Figure 3-44. Driver Configuration Menu

Table 3-19. Driver Configuration Menu Definitions Field Name Internal Scanner

Description When selected, the Internal Scanner option displays the Laser Scanner Configuration screen (see Figure 3-45). For the MK1000’s onboard internal laser scanner, the driver can be enabled or disabled and the default scan mode can be changed. (See Appendix C, Scanning Mode Programming Bar Codes for a list of the scan modes.) If the driver is disabled then the scanner is not initialized and it becomes possible for a user application to communicate with the scanner directly using the appropriate Com driver (i.e., C_SID_IO_UART2).

3-53

Page 100

MK1000 MicroKiosk Product Reference Guide

Table 3-19. Driver Configuration Menu Definitions (Continued) Field Name

Description

External/Aux Barcode Reader This option requires no modifications to support an undecoded external scanner. If an external decoded scanner is connected to the MK1000, the RS-232 port must be configured to match the scanner’s communication settings. (See the RS-232 Port description below for more information.)

3-54

RS-232 Port

When selected, the RS-232 Port option displays the RS-232 Configuration screen (see Figure 346). This screen allows configuration of various RS-232 port settings including: Baud Rate, Parity, Data Bits, Stop Bits, Flow Control, Echo Mode, and Rx Mode. These parameters must be set to the same settings used by the host or auxiliary RS-232 device (such as a decoded scanner).

RS-485 Port

When selected, the RS-485 Port option displays the RS-485 Configuration screen (see Figure 347).The RS-485 screen is the same in structure as the RS-232 screen above. The main difference is in the available number of Data Bits as well as extra modes in the Rx Mode configuration option. Hardware support exists for both 10-bit and 11-bit serial frames (start bit, data bits, parity, stop bits) only.

KEYPAD

When selected, the KEYPAD option allows you to toggle between disabling and enabling MK1000 keypad function buttons. When the keypad is “Enabled" (default state), the keypad buttons function as noted in Table 3-3 on page 3-29. When the keypad is “Disabled”, it can no longer be used to access any of the MK1000 menus. Keypad operation can be restored either through a Telnet session and accessing the "Drivers" menu, or by pressing and holding the ‘2’ and ‘3’ buttons simultaneously while the unit is booting up.

Page 101

Setup and Installation: Communication

Laser Scanner Configuration Screen From the Driver Configuration menu (see Figure 3-44 on page 3-53), press the Previous or Next buttons to move the "<" cursor to the Internal Scanner option and press the Enter button. To return to the Driver Configuration menu, press the ‘1’ button to escape. The Laser Scanner Config screen displays:

Laser Scanner Configuration Driver : ENABLED < Scan Mode: CYCLONE Beeper : DISABLED Startup :

Enable/Disable Laser Scanner Figure 3-45. Laser Scanner Config Screen

Table 3-20. Laser Scanner Config Screen Definitions Field Name

Description

Driver

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to enable or disable the scanner driver. If the driver is disabled then the scanner is not initialized and it becomes possible for a user application to communicate with the scanner directly using the appropriate Com driver (i.e., C_SID_IO_UART2). The default laser scanner driver setting for the MK1000 is ENABLED.

Scan Mode

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the scan mode. The default scan mode for the MK1000 is CYCLONE. (See Appendix C, Scanning Mode Programming Bar Codes for a list of the scan modes.)

3-55

Page 102

MK1000 MicroKiosk Product Reference Guide

Table 3-20. Laser Scanner Config Screen Definitions (Continued) Field Name

3-56

Description

Beeper

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to enable or disable the MK1000 beeper. When enabled, a beep sounds upon a successful decode. The default beeper setting for the MK1000 is DISABLED.

Startup

Press the Previous or Next buttons to move the "<" cursor to the Startup field to enter custom scanner parameter settings (in hexadecimal format). This field is a 30 character field that is used for custom scanner parameter settings. These parameter settings conform to the option codes and values defined in the SE 2223/3223 Integration Guide (p/n 70-36636-xx). Multiple codes and values may be entered, but all values must be in hexadecimal format. For example, to cause all decoded bar codes to be terminated with a carriage return/line feed character pair, the following startup string would be entered: E203690A6A00 where: E203 = Scan Data Transmission Option 3 <Data><Suffix1><Suffix2> 690A = Suffix1: 0x0D 6A00 = Suffix2: 0x00 The default Startup value for the MK1000 is blank.

Page 103

Setup and Installation: Communication

RS-232 Configuration Screen From the Driver Configuration menu (see Figure 3-44 on page 3-53), press the Previous or Next buttons to move the "<" cursor to either the RS-232 Port option and press the Enter button. To return to the Driver Configuration menu, press the ‘1’ button to escape. The RS-232 Config screen displays:

RS-232 Port Configuration Baud : 19200 < Echo: OFF Parity: NONE Rx : XPT Data : 8 BITS Stops : 1 BIT Flow : DTR/DSR Toggles Baud Rate Figure 3-46. RS-232 Config Screen

Table 3-21. RS-232 Config Screen Definitions Field Name

Description

Baud (Rate)

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Baud Rate. The default Baud Rate for MK1000 RS-232 port settings is 9600. Available Baud Rates: 110, 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, or 38400.

Parity

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select Parity. The default Parity for MK1000 RS-232 port settings is NONE. Available Parity settings: NONE, ODD, or EVEN.

3-57

Page 104

MK1000 MicroKiosk Product Reference Guide

Table 3-21. RS-232 Config Screen Definitions (Continued) Field Name

3-58

Description

Data (Bits)

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Data Bits. The default Data Bits setting for MK1000 RS-232 port settings is 8 BITS. Available Data Bits settings: 7 BITS or 8 BITS.

Stops (Bits)

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Stop Bits. The default Stop Bits setting for MK1000 RS-232 port settings is 1 BIT. Available Stop Bits settings: 1 BIT or 2 BITS.

Flow (Control)

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Flow Control. The default Flow Control setting for MK1000 RS232 port settings is DTR/DSR. Available Flow Control settings: DTR/DSR, BUSY, NONE, or XON/OFF.

Echo (Mode)

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Echo Mode. The default Echo Mode setting for MK1000 RS-232 port settings is OFF. Available Echo Mode settings: ON or OFF.

Rx (Mode)

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Rx Mode. The default Rx Mode setting for MK1000 RS-232 port settings is XPT. Available Rx Mode settings: PRTR, CMDL, or XPT.

Page 105

Setup and Installation: Communication

RS-485 Configuration Screen From the Driver Configuration menu (see Figure 3-44 on page 3-53), press the Previous or Next buttons to move the "<" cursor to either the RS-485 Port option and press the Enter button. To return to the Driver Configuration menu, press the ‘1’ button to escape. The RS-485 Config screen displays:

RS-232 Port Configuration Baud : 9600 < Echo: OFF Parity: NONE Rx : XPT Data : 8 BITS Stops : 1 BIT Flow : NONE Toggles Baud Rate Figure 3-47. RS-485 Config Screen The RS-485 Config screen includes the same structure and field definitions as the RS-232 Config screen with a slight difference: RS-485 includes extra Rx modes, and hardware support exists for 10-bit and 11-bit serial frames (start bit, data bits, parity, stop bits) only.

Table 3-22. RS-485 Config Screen Definitions Field Name Baud (Rate)

Description Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Baud Rate. The default Baud Rate for MK1000 RS-485 port settings is 9600. Available Baud Rates: 110, 300, 600, 1200, 2400, 4800, 9600, 14400, 19200, or 38400.

3-59

Page 106

MK1000 MicroKiosk Product Reference Guide

Table 3-22. RS-485 Config Screen Definitions (Continued) Field Name

3-60

Description

Parity

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select Parity. The default Parity for MK1000 RS-485 port settings is NONE. Available Parity settings: NONE, ODD, or EVEN.

Data (Bits)

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Data Bits. The default Data Bits setting for MK1000 RS-485 port settings is 8 BITS. Available Data Bits settings: 7 BITS or 8 BITS.

Stops (Bits)

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Stop Bits. The default Stop Bits setting for MK1000 RS-485 port settings is 1 BIT. Available Stop Bits settings: 1 BIT or 2 BITS.

Flow (Control)

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Flow Control. The default Flow Control setting for MK1000 RS485 port settings is DTR/DSR. Available Flow Control settings: DTR/DSR, BUSY, NONE, or XON/OFF.

Echo (Mode)

Press the Previous or Next buttons to move the "<" cursor to this field and toggle by pressing the Enter button to select the Echo Mode. The default Echo Mode setting for MK1000 RS-485 port settings is OFF. Available Echo Mode settings: ON or OFF.