The text of a manual · part 4 of 28
MK1000 MicroKiosk Product Reference Guide: Chapter 2 Setup and Installation: Mechanical, pages 29 to 37
Pages 29 to 37 of 240, from MK1000 MicroKiosk Product Reference Guide
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MK-1000
Page 29
Chapter 2 Setup and Installation: Mechanical Overview This chapter describes the hardware setup and installation of the MK1000. Topics covered in this chapter include mounting, providing power, and connecting communication cables (if required) for the following four MK1000 communication interfaces: •
•
Wireless Ethernet (2Mb or 11Mb RF) •
Power via AC outlet
•
Power via Power-over-Ethernet
Wired Ethernet (10Base-T cable) •
Power via AC outlet
•
Power via Power-over-Ethernet
•
Wired RS-485 (Serial cable)
•
Wired RS-232 (Serial cable). Note: After completing the mechanical installation of the MK1000, refer to Chapter 3, Setup and Installation: Communication to establish communication with the host.
2-1
Page 30
MK1000 MicroKiosk Product Reference Guide
Wired Ethernet Setup The MK1000 can communicate with a host via a wired Ethernet connection (10Base-T cable). When communicating in this manner the MK1000 can be powered either using the MK1000’s power supply connected to an AC outlet, or by receiving Power-over-Ethernet through the Ethernet cable.
Wired Ethernet: Power via AC Outlet With this installation option, the MK1000 communicates to the host via a 10Base-T Ethernet cable and receives power via a power supply plugged into an AC outlet. To install the MK1000, follow the instructions below. 1. Provide power to the MK1000 using its power supply. •
Insert the round barrel connector at the end of the power supply cable into the MK1000’s Power port. (See Figure 1-1 on page 1-3 for port locations.)
•
Plug the power supply into a wall outlet.
2. Attach the Ethernet cable. •
Connect the Ethernet cable to the LAN port on the MK1000. (See Figure 1-1 on page 1-3 for port locations.) Ensure the Ethernet cable is terminated according to the Ethernet Pin-Outs: Obtaining Power via AC Power Supply described in Table 2-1 and Table 2-2.
•
Plug the other end of the Ethernet cable into the host system’s LAN port.
3. To mount the MK1000, see Mounting the MK1000 on page 2-11. After completing the mechanical installation of the MK1000, refer to Chapter 3, Setup and Installation: Communication to establish communication with the host.
2-2
Page 31
Setup and Installation: Mechanical
Wired Ethernet: Power via Power-over-Ethernet With this installation option, in addition to the MK1000 communicating to the host via a 10Base-T Ethernet cable, the MK1000 also simultaneously receives its power via the same Ethernet cable. Note: Power-over-Ethernet should NOT be used in conjunction with an external power supply connected to the power port on the MK1000 otherwise damage can occur to the MK1000 and/or network. To install the MK1000, follow the instructions below. 1. Attach the Ethernet cable. •
Connect the Ethernet cable to the LAN port on the MK1000. (See Figure 1-1 on page 1-3 for port locations.) Ensure the Ethernet cable is terminated according to the Ethernet Pin-Outs: Obtaining Power via Power-over-Ethernet described in Table 2-3 and Table 2-4.
•
Plug the other end of the Ethernet cable into the Bias-T (Power-over-Ethernet) module.
2. Connect a patch cable from the Bias-T (Power-over-Ethernet) module to your host system’s LAN port. 3. To mount the MK1000, see Mounting the MK1000 on page 2-11. After completing the mechanical installation of the MK1000, refer to Chapter 3, Setup and Installation: Communication to establish communication with the host.
2-3
Page 32
MK1000 MicroKiosk Product Reference Guide
Wireless Ethernet Setup The MK1000 can communicate with a host via a wireless (RF) Ethernet connection. When communicating in this manner the MK1000 can be powered either using the MK1000’s power supply connected to an AC outlet, or by receiving Power-over-Ethernet via cable.
Wireless Ethernet: Power via AC Outlet With this installation option, the MK1000 communicates to the host via a wireless (RF) connection and receives power via a power supply plugged into an AC outlet. To install the MK1000, follow the instructions below. 1. Provide power to the MK1000 using its power supply. •
Insert the round barrel connector at the end of the power supply cable into the MK1000’s Power port. (See Figure 1-1 on page 1-3 for port locations.)
•
Plug the power supply into a wall outlet.
2. To mount the MK1000, see Mounting the MK1000 on page 2-11. After completing the mechanical installation of the MK1000, refer to Chapter 3, Setup and Installation: Communication to establish communication with the host.
2-4
Page 33
Setup and Installation: Mechanical
Wireless Ethernet: Power via Power-over-Ethernet With this installation option, the MK1000 communicates to the host via a wireless (RF) connection and receives power via an Ethernet cable. Note: This Ethernet cable does NOT provide data to the MK1000. To install the MK1000, follow the instructions below. 1. Attach the Ethernet cable to provide power to the MK1000. •
Connect the Ethernet cable to the LAN port on the MK1000. (See Figure 1-1 on page 1-3 for port locations.) Ensure the Ethernet cable is terminated according to the Ethernet Pin-Outs: Obtaining Power via Power-over-Ethernet described in Table 2-3 and Table 2-4.
•
Plug the other end of the Ethernet cable in the hub.
2. Connect a patch cable from the Bias-T (Power-over-Ethernet) module to your host system’s LAN port. 3. To mount the MK1000, see Mounting the MK1000 on page 2-11. After completing the mechanical installation of the MK1000, refer to Chapter 3, Setup and Installation: Communication to establish communication with the host.
2-5
Page 34
MK1000 MicroKiosk Product Reference Guide
Wired RS-485 Setup The MK1000 can communicate with a host via a wired RS-485 Serial connection while receiving power via a power supply plugged into an AC outlet. For MK1000 devices installed where pre-existing PCK 9100 wiring exists, an RS-485 pinout converter can be used. This pin-out converter maps the PCK 9100 signals into the required MK1000 pin-out and attaches to the existing PCK 9100 wiring, and then into the MK1000. RS-485 is a two-wire differential signal: RS-485 signal and RS-485 inverted signal. See Figure 2-2 on page 2-8 for an illustration of the two-wire differential signal. When installing an RS-485 configuration, ensure each MK1000 is connected directly to the RS-485 bus (see Figure 2-1). Wire nuts or connector block may be used
1
2
3
4
Figure 2-1. Connector Block The cable required for an RS-485 installation should meet or exceed the following specifications: •
1 twisted pair 26 AWG (7/34) tinned copper
• twisted pair foil wrapped - 100% coverage
• nominal impedance 120 ohms
• capacitance between twisted pair 10-25 pf per foot
• capacitance between conductors & shield 20-35 pf per foot
•
DC resistance of each conductor 45 ohms per 1000 feet
•
DC resistance of shield 10 ohms per 1000 feet.
If your host does not support RS-485 and you wish to use RS-485 as your communication interface, an RS-232 to RS-485 conversion box is required. The conversion box must be sourced locally and is not available from Symbol Technologies.
2-6
Page 35
Setup and Installation: Mechanical
To install the MK1000 with a host that does not support RS-485, follow the instructions below. 1. Provide power to the MK1000 using its power supply. •
Insert the round barrel connector at the end of the power supply cable into the MK1000’s Power port. (See Figure 1-1 on page 1-3 for port locations.)
•
Plug the power supply into a wall outlet.
2. Connect the conversion box to the host using an RS-232 cable. 3. Attach the RS-485 Serial cable. •
Connect the RS-485 Serial cable to the LAN port on the MK1000. (See Figure 1-1 on page 1-3 for port locations.) Ensure the Serial cable is terminated according to the RS-485 Connectors - LAN Port described in Table 2-5.
•
Plug the other end of the RS-485 Serial cable into the converter box.
4. To mount the MK1000, see Mounting the MK1000 on page 2-11. After completing the mechanical installation of the MK1000, refer to Chapter 3, Setup and Installation: Communication to establish communication with the host.
2-7
Page 36
2-8
Figure 2-2. RS-485 Two-Wire Serial Network
Rt
GWG
GWG
100Ω 1/2 W 1/2 W
100Ω
120Ω 1/2W
Circuit ground or circuit common
Green wire ground or power system ground
RS-232
RS-232/RS-485 Conversion Box
GWG
2
3
100Ω
4
GWG
100Ω
1
2
3
100Ω
4
Recommended RS-485 Two-Wire Multidrop NetWork
100Ω
1
Rt
Termination Resistors at Both Ends
4000 Ft. Maximum
1/2 W
100Ω
Rt
2
3
1/2 W
100Ω
1
GW
4
MK1000 MicroKiosk Product Reference Guide
Page 37
Setup and Installation: Mechanical
Wired RS-232 Setup The MK1000 can communicate with a host via a Serial cable connected to the Com/ Scanner port while receiving power via a power supply plugged into and AC outlet. To install the MK1000, follow the instructions below. 1. Provide power to the MK1000 using its power supply. •
Insert the round barrel connector at the end of the power supply cable into the MK1000’s Power port. (See Figure 1-1 on page 1-3 for port locations.)
•
Plug the power supply into a wall outlet.
2. Attach the RS-232 Serial cable. •
Connect the RS-232 Serial cable to the Com/Scanner port on the MK1000. (See Figure 1-1 on page 1-3 for port locations.) Ensure the Serial cable is terminated according to the Serial/RS-232 Communication pin-outs described in Table 2-6.
•
Plug the other end of the Serial cable into the host.
3. To mount the MK1000, see Mounting the MK1000 on page 2-11. After completing the mechanical installation of the MK1000, refer to Chapter 3, Setup and Installation: Communication to establish communication with the host.
2-9