The text of a manual · part 15 of 28
MK1000 MicroKiosk Product Reference Guide: Chapter 5 PCK Emulation, pages 127 to 136
Pages 127 to 136 of 240, from MK1000 MicroKiosk Product Reference Guide
The original document is the PDF (2.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Symbol MK-1000
Page 127
PCK Emulation
Draw Commands Table 5-5. Draw Commands Command
Description
Syntax
Example
Draw Point
Draws a single ESC [Px;PyP point on the display
Draw Line
Draws a line ESC[Px;Py; Px;PyL ESC[5;10;200;50L draws a between two points line from (5,10) to (200,50) in the current color. Note: If either endpoint is off the screen, the line is not drawn.
Draw Rectangle
Draws a rectangle ESC[Px1;Py1;Px2; between two Py2;PfR points. If Pf = 1, the rectangle is filled. If Pf = 0, it is not filled.
Set Color
Sets the drawing color for subsequent graphics commands.
Draw Bitmap
Draws the bitmap ESC[Pi;Px;Py;PmD specified by Pi at location (Px,Py) on the screen, with the upper-left corner at (Px,Py). The pixels are combined with the current screen image according to the Pm parameter.
ESC[30m sets the color to black. ESC[37m sets the color to white.
ESC[10;20P sets a point at column 1 row 20 in the current color.
ESC[10;10;100;40;1R draws a filled rectangle from (10,10) to (100,40) in the current color. Note: If any corner is off the screen, the rectangle is not drawn. N/A
ESC[42;10;25;1D draws bitmap #42 at (10,25) with its colors XORed with the current screen image.
5-11
Page 128
MK1000 MicroKiosk Product Reference Guide
Text/Font Commands Table 5-6. Text/Font Commands Command
Description
Syntax
Example
Select Font
Font number Pi ESC[PiF becomes the current font for any subsequent text output.
ESC[37F This is a test This sets the current font to #37, then draws the text "This is a test."
Font Height Query (Supported in PCK emulation versions 1.06 or greater)
Returns the height, in pixels, of the currently selected font.
Unit responds with the ASCII representation of the font height.
Set Text Drawing Mode
Sets the drawing mode ESC[PmM for subsequent text output commands. When Pm = 0 any text output overlays the current image, when Pm = 1 it is XORed with the current image.
Position Cursor
Positions text cursor to ESC[Px; PyT a specified point on the display, characters are drawn with the left side of the character cell at the X cursor position, and the character baseline at the Y cursor position.
Font Screen Position (Supported in PCK emulation versions 1.06 or greater)
Changes the current position at which the unit draws fonts to Px, Py. The positioning is done by the current font's height and average width.
5-12
ESC[H
ESC[Px;Pyp
ESC[10;3p Draws fonts to column 10, row 3.
Page 129
PCK Emulation
Message Commands A message is composed of display commands and text to be displayed. Commands are executed in the same manner as host commands. The MK1000 has four default messages (see Table 5-4 on page 5-10) that can be replaced using the Resource Manager to create messages with the same ID numbers. The following commands display user-defined messages, and send messages to store in RAM. Table 5-7. Message Commands Message
Syntax
Description
Display Stored Messages
ESC[PiJ
Message number Pi is displayed after the current packet, and pending packets are processed. Messages stored in RAM override any messages from Resource files with the same ID. Messages in RAM or from Resource files override default messages. Be sure messages do not call each other recursively. A message called from another is not displayed until the first message is done. Approximately 10 messages waiting to be displayed can be stored. Commands from the host are also stored.
Store Message
ESC[PiK <Message Text>
The MK1000 stores everything in the packet following this command as a message with ID number Pi. This message can be displayed using the Display Stored Message command above. Up to 50 messages of up to 20 characters each may be stored. The message may contain any text or commands the MK1000 supports, including commands to display bitmaps, change fonts, etc.
Flush Stored Messages ESC[I
This command deletes all messages stored in RAM.
5-13
Page 130
MK1000 MicroKiosk Product Reference Guide
MK1000 Command Examples - Host to PCK Software All commands have the following format: stx FF <Command Syntax> <Data> etx lrc where: stx = 02 (Start of Transmission) FF = 0C Command Syntax = Optional text, font, or position command (e.g., xy coordinates to position a message) <Data> = message etx = 03 lrc = Exclusive - or of all characters transmitted except for the stx character (calculated longitudinal redundancy check).
Command Syntax Examples Table 5-8. Clear Screen 02
0C
03
0F stx
FF etx lrc
Table 5-9. Send Text esc [
1
;
1
T
Table 5-10. Position Cursor Then Send Text esc [
5-14
Px
;
Py
T
Page 131
PCK Emulation
Table 5-11. Display Stored Message esc [
Pi
J
Complete String Examples Table 5-12. Clear Screen & Send “HI” 02
0C
1B
5B
31
3B
31
54
48
49
03
21 stx
FF esc
[
1
;
1
T
H
I etx lrc
Table 5-13. Clear Screen & Send “HI” at Position 100x32 02
0C
1B
5B
31
30
30
3B
33
32
54
48
49
03
11 stx
FF esc
[
1
0
0
;
3
2
T
H
I etx lrc
Table 5-14. Clear Screen & Send Stored Message #1002 02
0C
1B
5B
31
30
30
32
4A
03
06 stx
FF esc
[
1
0
0
2
J etx lrc
5-15
Page 132
MK1000 MicroKiosk Product Reference Guide
Button Press - Event Notification When one of the MK1000 function buttons is depressed, a string is sent to the host where <Keypad digit, 1 through 4> is the number of the button pressed. For example, "BTN4" is sent to the host when the right most button, ‘4’, is pressed. This event notification must be surrounded by the normal framing characters used by the PCK emulation firmware (which are dependent on communications type described in Table 5-2 on page 5-3).
Button Event Sent to Host RS-232 MK1000
Host
<STX>BTN4<ETX><LRC> <ACK> <EOT>
Scan Engine Commands Changing the Scanning Mode (Scan Pattern) To change the scanning mode, the host sends the MK1000 the following command sequence: <Esc> [ <scanning mode number> s The following is a list of scanning mode numbers: Number
Scan Mode
1
Smart Raster
2
Always Raster
6
Cyclone Omnidirectional (1D scanning only)
7
Semi-Omni Pattern
To change the scanning mode to Smart Raster, the scanning mode number 1 would be used.
5-16
Page 133
PCK Emulation
To change the scanning mode from Cyclone (factory default) to Smart Raster, use the following syntax: MK1000
Host
<STX><ESC>[1s<ETX> <LRC> <ACK> <EOT>
Pass Through Scanner Commands A special "ParamSend" escape sequence is available in the PCK emulation application to allow "pass through" scanner programming commands. These scanner commands consist of the "PARAM_SEND" programming group as defined in the Simple Serial Interface (SSI) Programmer's Guide, 72-40451-xx, along with the SE3223 scanner parameter values as defined in the SE 2223/3223 Scan Engine Integration Guide, 70-36636-xx. The MK1000 "ParamSend" escape sequence, along with the scanner parameter data, allows complete customization of the scanner’s operational behavior. Note: Parameter changes can be issued singly. The general format of the ParamSend message is: <ESC>[255s<0xC6><0x04><0x00><0xFF><Parameter><ParamData> Where: <ESC>
= The Escape control character, 0x1B.
[255s
= The MK1000 ParamSend command string.
<0xC6>
= The SSI_PARAM_SEND command byte. Required.
<0x04>
= Data from the host. Required.
<0x00>
= The status byte. The value 0 indicates that this is a temporary parameter change. You MUST have this and it must be set to zero. Parameter changes are only effective until the MK1000 is rebooted.
<0xFF>
= The beep code. The scanner's beeper output is not monitored. 0xFF indicates no beep, and it should be set to 0xFF.
5-17
Page 134
MK1000 MicroKiosk Product Reference Guide
<Parameter> = Any valid SSI ParamSend value. <ParamData> = Any valid SSI ParamSend data value.
Redirecting Data To The Serial Port ESC[B<Data For Auxiliary Port> redirects data to the Serial port. All data following this command up to the end of the current packet is sent out the auxiliary port. Data is sent "as is" without processing, except for the Shift Out/In control codes, to allow the host to send all 256 possible codes to the auxiliary port. Note: When the MK1000 is running in PCK emulation mode, data received on the Auxiliary port is sent to the host. It is sent in packets, up to a maximum of 128 bytes, as the data is received. It is framed according to the current Software Handshaking Type setup in the unit.
Beep Commands ESC[PbS sounds the beeper. Pb is the beep code parameter that is, the beep code value specified in ASCII digits (see the table below). Table 5-15. Beep Sequences Decimal Value
5-18
Beep Sequence
0
1 Short High Beep
1
2 Short High Beeps
2
3 Short High Beeps
3
4 Short High Beeps
4
5 Short High Beeps
5
1 Short Low Beep
6
2 Short Low Beeps
7
3 Short Low Beeps
8
4 Short Low Beeps
Page 135
PCK Emulation
Table 5-15. Beep Sequences (Continued) Decimal Value
Beep Sequence
9
5 Short Low Beeps
10
1 Long High Beep
11
2 Long High Beeps
12
3 Long High Beeps
13
5 Long High Beeps
14
2 Long High Beeps
15
1 Long Low Beep
16
2 Long Low Beeps
17
3 Long Low Beeps
18
4 Long Low Beeps
19
5 Long Low Beeps
20
Fast Hi-Lo-Hi-Lo Warble
21
Slow Hi-Lo-Hi-Lo Warble
22
Hi-Low Beep
23
Low-High Beep
24
Hi-Lo-Hi Beep
25
Lo-Hi-Lo Beep
5-19
Page 136
MK1000 MicroKiosk Product Reference Guide
5-20