Page 47

Chapter 3 Setup and Installation: Communication Overview This chapter describes the steps required to establish communication between the MK1000 and a host. Note: The host must be able to support either the RS-232 or Ethernet communication interface. Common host operating systems that support these interfaces include Windows, Unix, DOS, and IBM 468x/469x. Topics covered in this chapter include: •

Communication protocol (PCK emulation) overview

•

Selecting a communication interface

•

Configuring for host communication via the System menu

•

Configuring for host communication via the PCK Configuration menu

•

Configuring for host communication via a Telnet client.

Before communications with the host is established, you must determine which communication interface to use.

3-1

Page 48

MK1000 MicroKiosk Product Reference Guide

Communication Protocol Overview The MK1000 is shipped with the PCK emulation communication protocol on-board. The Symbol PCK emulation application* is a PCK9100/9140 emulator for the Symbol MK1000. The Symbol PCK emulation application uses a proprietary command set developed by Symbol Technologies for use with its Kiosk Scanning Solutions. The PCK emulation application allows the MK1000 to behave like a Symbol PCK9100/9140 and interact with PCK9100/9140 compatible applications on the host. For more information on the PCK emulation application see Chapter 5, PCK Emulation. Note: *The MK1000’s PCK emulation application is not compatible with pre-existing PCK9142/9144/9130 applications.

Communication Interface Overview Before establishing communications with the host you must determine which communication interface to use. Your MK1000 may support up to four communication interfaces. The four types of interfaces are listed in Table 3-1. The number and type of communication interfaces your unit has is specified in its model number. For a list of MK1000 model numbers and their supported onboard communication interfaces see the Appendix F, Troubleshooting. Table 3-1. Communication Interfaces Versus Communication Protocols Communication Protocol

3-2

Communication Interface

PCK Emulation

Ethernet - Wireless (2 Mbps or 11 Mbps RF)

x

Ethernet - Wired (10Base-T Cable)

x

RS-485 (Wired Serial)

x

RS-232 (Wired Serial)

x

Page 49

Setup and Installation: Communication

Configuring the MK1000 for Host Communication Now that the communication interface has been selected, you are ready to configure the MK1000 for communication with your host. Table 3-2 shows the different methods available for configuring the MK1000. Table 3-2. Methods of Configuring the MK1000 Remote

Computer - PCK Configuration Menu

Bar codes

Bar codes and 4 Buttons

X

- System Menu - Telnet Session

Local

- See Notes 1 and 3 X

X

Comments

- See Note 4 - See Note 2

Notes: 1. From the PCK Configuration menu the following parameters cannot be configured: the RF Settings, ESS ID, Encryption, Key ID, and Key Management. These parameters can be configured from the System menu and/or a Telnet Session. 2. Telnet sessions require an Ethernet connection between the host and the MK1000. 3. PCK Configuration programming bar codes are located in Appendix B, PCK Configuration Programming Bar Codes. 4. System menu programming bar codes are available in Appendix A, Configuration Menu Programming Bar Codes.

3-3

Page 50

MK1000 MicroKiosk Product Reference Guide

Configuring via the PCK Configuration Menu Overview The MK1000 can be configured for operation with PCK based applications using the PCK Configuration menu. The PCK Configuration menu can be accessed locally by scanning programming barcodes, which are available in Appendix B, PCK Configuration Programming Bar Codes. From the PCK Configuration menu all MK1000 parameters can be accessed except the RF Settings, ESS ID, Encryption, Key ID, and Key Management. These parameters can only be accessed from the System menu and/or a Telnet session. For information on alternate methods of configuring the MK1000, see page 3-3.

3-4

Page 51

Setup and Installation: Communication

MAP: PCK Configuration Menu The following map can be used to assist in the navigation of the PCK application.

Figure 3-1. Navigating the PCK Configuration Menus/Screens 3-5

Page 52

MK1000 MicroKiosk Product Reference Guide

Entering, Navigating & Saving Changes Entering the PCK Configuration Menu To access the PCK Configuration menu scan the Enter PCK Configuration Menu programming bar code, available in Appendix B, PCK Configuration Programming Bar Codes. Note: The PCK Configuration and MK1000 System menus cannot be accessed simultaneously. Only one menu can be active at a time. When the bar code is scanned, the following menu displays:

PCK Configuration Current Host: TCP/IP, WIRELESS 1. Change Interface 2. Change Host Params 3. Change Host Config 4. Edit Aux Port Params Scan 1-4 to Set Item Figure 3-2. PCK Configuration Menu

Navigating the Main Menu To navigate the main menu, scan the numeric programming bar code in Appendix B, PCK Configuration Programming Bar Codes that corresponds to the menu option (parameter) you wish to review/change. For example, if you wish to change host parameters, you can access the Select Host Params screen by scanning the “2” bar code at the PCK Configuration menu.

Saving Changes After making your desired changes on a screen, you can save the changes by scanning the Save & Exit bar code on page B-4. Note: Changes must be saved on each screen before exiting the screen.

3-6

Page 53

Setup and Installation: Communication

Escaping a Screen Without Saving Changes If you have accidentally entered a screen and wish to exit it WITHOUT making ANY changes, scan the Cancel bar code on page B-5. Note: Some screens may require scanning the Cancel bar code twice, or scanning a numeric bar code selection.

Exiting the PCK Configuration Menu When all desired changes are made, scan the Exit and Save Changes bar code on page B-3 to exit PCK emulation configuration.

Selecting an Option (Parameter) from a List of Options To select an parameter from a list, scan the numeric programming bar code in Appendix B, PCK Configuration Programming Bar Codes that corresponds to the parameter you wish to select. For example, to change the communication interface to wired Ethernet, navigate the main menu and make your communication interface selection as follows: 1. Scan the Enter PCK Configuration Menu bar code to access the PCK Configuration menu. 2. Scan the number “1” bar code to access the Select Interface Type screen. 3. Scan the number “1” bar code to choose Wired Ethernet (10BaseT) as your communication interface. 4. When the number “1” bar code is scanned and Wired Ethernet (10BaseT) is selected, you are returned to the PCK Configuration menu. 5. Continue with additional changes by scanning the appropriate numeric bar code to access another screen, or to initiate operation of the MK1000 in PCK emulation mode, scan the Save & Exit bar code. Note: Scan the Cancel bar code to exit WITHOUT saving ANY of your changes.

3-7

Page 54

MK1000 MicroKiosk Product Reference Guide

Entering Field Data (Numeric Values) Data fields, such as IP Address, require the user to enter a combination of numeric values. On the appropriate screen, enter the numeric values by scanning the bar codes that correspond to the data you wish to enter. For example, to enter a numeric value such as an IP Address: 1. Scan the Enter PCK Configuration Menu bar code to access the PCK Configuration menu. 2. Ensure the communication interface is set to Ethernet. Your “current (communication interface) host setting” is displayed on the second line of the PCK Configuration menu. •

If your current setting is Ethernet (wired or wireless and TCP/IP or UDP/IP), no change is necessary.

•

If your current setting is not Ethernet, scan the “1” bar code to change the interface and scan the “1” bar code again to select Ethernet.

3. Once your communication interface is confirmed, check and change the MK1000’s IP address by scanning the number “3” bar code (Change Host Config) at the PCK Configuration menu to access the TCP/IP Configuration Page 1. 4. Scan the number “1” bar code (TCP/IP) to access TCP/IP Configuration Page 1 screen. 5. Scan the number “2” bar code (IP Address) to access the IP address data field. This screen displays the current IP address field (Curr IP Addr) and the new IP address field (New IP Addr). 6. To enter a new IP address, scan the numeric bar codes that correspond to the IP address you desire. Note that the IP address field requires you to scan three digits for each segment in the address for the segment separator "dots" to be applied correctly (see Example: Entering a Numeric Value -- IP Address on page 3-9). 7. When you have completed scanning the IP address via numeric bar codes, scan the Save & Exit bar code to save your changes and exit the current screen. The MK1000 changes its IP address to the new value you entered and returns you to the previous screen. or If you do not wish to change the current (IP address) setting, scan the Cancel bar code to exit the WITHOUT saving your changes.

3-8

Page 55

Setup and Installation: Communication

Example: Entering a Numeric Value -- IP Address To enter a new IP address of 234.239.5.16, scan the following programming bar codes in this order: Scan Bar Code

Screen Display

2

2

3

23

4

234

2

234.2

3

234.23

9

234.239

0

234.239.0

0

234.239.00

5

234.239.005

0

234.239.005.0

1

234.239.005.01

6

234.239.005.016

Save & Exit

Previous screen (I/P address changed)

Save & Exit

Main menu

Save & Exit

Exit main menu and initiate operation of the MK1000 in PCK emulation mode.

3-9

Page 56

MK1000 MicroKiosk Product Reference Guide

PCK Configuration Menu The main PCK Configuration menu displays when the Enter PCK Configuration Menu programming bar code is scanned (see Figure 3-2).

Selecting an Interface Type Change Interface - PCK Configuration Menu Option 1 To select or change the interface type that the MK1000 uses to talk to a host, choose Change Interface at the PCK Configuration menu by scanning the "1" bar code located in the section Numeric Bar Codes on page B-7. The Select Interface Type screen displays.

Select Interface Type: 1. Wired Ethernet 2. Wireless Ethernet

Scan 1 or 2 to Select Item Figure 3-3. Select Interface Type Screen Scanning a "1" or "2" bar code sets the type (Wired 10BaseT or Wireless) and returns you to the PCK Configuration menu.

3-10