Manual · Qqest
Time Force II Hardware Guide
Manual234 pagesPDF 1.1 MB
Hardware guide for Qqest TimeForce II time clocks: ETC 100, IntelliClock IQ 300 to IQ 1000, and the V800 and V850 fingerprint clocks.
Covers · 1 model
The models it covers
Summary
What is in it
The hardware guide for the time clocks used with Qqest TimeForce II software. It covers installing the ClockLink utility and Clock Server, identifying your clock model, and setting up serial, modem, Ethernet, wireless and cellular clocks. Model chapters cover the ETC 100, the IQ 300, 400, 500 and 1000 IntelliClocks, and the V800 and V850 Velocity clocks, including finger template enrollment and punching. Later chapters cover scheduled downloads, troubleshooting, bells, door readers, PoE clocks, the enrollment station and cable pinouts.
Its parts
- Introduction
- Installing the ClockLink Utility
- Clock Server
- Determining Your Clock Model
- ETC 100 Model Clock
- IntelliClock Setup Instructions
- Using the Model IQ 300, 400 or 500 IntelliClock
- Using the Model IQ 1000 IntelliClock
- Velocity Clocks
- Downloading Your Time Clock
- Clock Communication Troubleshooting
- Installing a Bell/Buzzer
- Installing an External Door Security Reader
- PoE Clocks
- Static Discharge Plate
From the manual
Key facts from this manual
Each line names its page in the PDF.
Qqest's TimeForce II Hardware Guide, compiled September 13, 2011, for the ETC 100, the IntelliClock IQ 300, IQ 400, IQ 500 and IQ 1000, and the Velocity V800 and V850 time clocks. For the V800 it covers mounting, power, serial, modem, Ethernet, wireless and PoE connections, network settings, On Demand uploads and communication troubleshooting.
- Device
- Velocity time clock for basic time and attendance tracking with the TimeForce II software p. 13, 14
- Data entry
- Keypad entry and finger ID verification; no card reader p. 14
- Communication
- Ethernet, serial, modem, wireless or cellular modem versions p. 119, 120, 123
- Power
- 110-120 VAC outlet; PoE versions take all power from the Ethernet cable p. 119, 201
- Serial connection
- RJ-11 at the clock, RS-232 9-pin D-connector at the computer; USB through a Keyspan USB to serial adapter p. 120
- Ethernet
- Standard CAT5 straight-through cable, not crossover; a 20 ft. cable comes with Ethernet clocks p. 120, 222
- Network port
- TCP port 5402 must be open over wide area networks for Velocity series clocks p. 184
- Wireless
- 802.11 a and b; optimum range 50 to 100 feet from the access point p. 123
- PoE
- V800 PoE version; needs a switch, router or hub that is IEEE 802.3af compliant p. 201, 202
- Network settings
- IP address, subnet mask and gateway set at the keypad, or DHCP p. 121, 122, 123
- Rugged Edition
- Portable industrial version with a battery giving at least 12 hours per charge, from vehicle power or an outlet p. 117, 121
- Mounting
- Wall mounting plate with four holes; mounting screws included p. 119
- Clock ID
- Up to 10 digits, set at the clock keypad p. 118
- Upload schedules
- On Demand Ethernet clock: Every Midnight, 9, 1 & 6:00, Manual Only, Real Time or On Demand p. 173
What this manual walks you through
- Mounting the clock and connecting power and the communications cable p. 119, 120
- Telling a straight-through network cable from a crossover cable p. 120
- Charging the Rugged Edition battery p. 121
- Setting the IP address, subnet mask, gateway and DHCP at the clock keypad p. 121, 122, 123
- Configuring the wireless clock p. 123, 124
- Creating a V800 clock profile in TimeForce p. 130, 131
- Setting the push server IP and upload times on an On Demand Ethernet clock p. 171, 172, 173
- Troubleshooting serial and Ethernet clock communication p. 181, 184
- Installing and identifying a PoE clock p. 201, 202
- Serial cable lengths and the DB9 to RJ12 pinout p. 219, 220
Good to know
- Power surges can permanently damage the clock; a battery backup or surge protector is highly recommended. p. 119
- An On Demand clock cannot take a static IP address; with DHCP its address may change each time power is cycled. p. 121
- Communication beyond 100 feet from the access point is not assured, even where an access point advertises up to 1000 feet. p. 123
- Serial clocks: the cable from the computer to the master clock must not exceed 200 feet; cables over 20 feet should be shielded and unspliced. p. 219
- Modem clocks need a two wire phone cable, not a standard four wire cable, to avoid damage to the clock. p. 222
Questions this manual answers
Does the Qqest V800 time clock use swipe cards?
No. Velocity clocks have no card reader; employees punch by keypad entry and finger ID verification. p. 14
How do I connect a serial V800 clock to a computer?
Plug the RJ-11 end into the right side port on the bottom center of the clock and the 9-pin RS-232 end into a serial port; a Keyspan USB to serial adapter also works. p. 120
What port does a V800 Ethernet clock use over a WAN?
Port 5402 must be open; Velocity series clocks use TCP. p. 184
Can the V800 be powered over Ethernet?
Yes, a V800 PoE version exists; it needs a PoE switch, router or hub that is IEEE 802.3af compliant. p. 201, 202
How long does the V800 Rugged Edition battery last?
At least 12 hours per charge; charge it 24 hours before first use and overnight after daily use. p. 121
Contents
Chapters and sections
Each line opens the PDF at its page.
- Introduction13
- Installing the ClockLink Utility15
- Clock Server17
- Determining Your Clock Model23
- ETC 100 Model Clock29
- IntelliClock Setup Instructions35
- Using the Model IQ 300, 400 or 500 IntelliClock47
- Using the Model IQ 1000 IntelliClock63
- Velocity Clocks117
44 more lines, from page 143 on
- Customizing Time Clock Information143
- Downloading Your Time Clock175
- Clock Communication Troubleshooting181
- Installing a Bell/Buzzer185
- Installing an External Door Security Reader197
- PoE Clocks201
- Static Discharge Plate203
- Fingerprint Sensor Security Guard205
- Finger Enrollment Station207
- Cable Specifications219
- How Do I Create Clock Groups?223
- Finger ID Sensor Cleaning Instructions225
- Index227
The whole text · 30 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Pages 1 to 41-4
- Table of Contents5-12
- Pages 13 to 1613-16
- Clock Server17-22
- Determining Your Clock Model23-28
- ETC 100 Model Clock29-34
- IntelliClock Setup Instructions35-46
- Using the Model IQ 300, 400 or 500 IntelliClock, pages 47 to 5447-54
- Using the Model IQ 300, 400 or 500 IntelliClock, pages 55 to 6255-62
- Using the Model IQ 1000 IntelliClock, pages 63 to 7163-71
- Using the Model IQ 1000 IntelliClock, pages 72 to 8072-80
- Using the Model IQ 1000 IntelliClock, pages 81 to 8981-89
- Using the Model IQ 1000 IntelliClock, pages 90 to 9890-98
- Using the Model IQ 1000 IntelliClock, pages 99 to 10799-107
- Using the Model IQ 1000 IntelliClock, pages 108 to 116108-116
- Velocity Clocks, pages 117 to 126117-126
- Velocity Clocks, pages 127 to 136127-136
- Velocity Clocks, pages 137 to 146137-146
- Velocity Clocks, pages 147 to 156147-156
- Velocity Clocks, pages 157 to 166157-166
- Velocity Clocks, pages 167 to 174167-174
- Downloading Your Time Clock175-180
- Clock Communication Troubleshooting181-184
- Installing a Bell/Buzzer185-196
- Installing an External Door Security Reader197-200
- Pages 201 to 204201-204
- Pages 205 to 218205-218
- Cable Specifications219-222
- Pages 223 to 226223-226
- Index227-234
The file


