The hardware guide for the time clocks used with Qqest TimeForce II software. It covers installing the ClockLink utility and Clock Server, identifying your clock model, and setting up serial, modem, Ethernet, wireless and cellular clocks. Model chapters cover the ETC 100, the IQ 300, 400, 500 and 1000 IntelliClocks, and the V800 and V850 Velocity clocks, including finger template enrollment and punching. Later chapters cover scheduled downloads, troubleshooting, bells, door readers, PoE clocks, the enrollment station and cable pinouts.

Its parts

  1. Introduction
  2. Installing the ClockLink Utility
  3. Clock Server
  4. Determining Your Clock Model
  5. ETC 100 Model Clock
  6. IntelliClock Setup Instructions
  7. Using the Model IQ 300, 400 or 500 IntelliClock
  8. Using the Model IQ 1000 IntelliClock
  9. Velocity Clocks
  10. Downloading Your Time Clock
  11. Clock Communication Troubleshooting
  12. Installing a Bell/Buzzer
  13. Installing an External Door Security Reader
  14. PoE Clocks
  15. Static Discharge Plate

From the manual

Key facts from this manual

Each line names its page in the PDF.

Qqest's TimeForce II Hardware Guide, compiled September 13, 2011, for the ETC 100, the IntelliClock IQ 300, IQ 400, IQ 500 and IQ 1000, and the Velocity V800 and V850 time clocks. For the V800 it covers mounting, power, serial, modem, Ethernet, wireless and PoE connections, network settings, On Demand uploads and communication troubleshooting.

Read for this summary: pages 1 to 4, 13 to 14, 117 to 124, 130 to 131, 171 to 173, 181, 184, 201 to 202 and 219 to 222 of 234.

Device
Velocity time clock for basic time and attendance tracking with the TimeForce II software p. 13, 14
Data entry
Keypad entry and finger ID verification; no card reader p. 14
Communication
Ethernet, serial, modem, wireless or cellular modem versions p. 119, 120, 123
Power
110-120 VAC outlet; PoE versions take all power from the Ethernet cable p. 119, 201
Serial connection
RJ-11 at the clock, RS-232 9-pin D-connector at the computer; USB through a Keyspan USB to serial adapter p. 120
Ethernet
Standard CAT5 straight-through cable, not crossover; a 20 ft. cable comes with Ethernet clocks p. 120, 222
Network port
TCP port 5402 must be open over wide area networks for Velocity series clocks p. 184
Wireless
802.11 a and b; optimum range 50 to 100 feet from the access point p. 123
PoE
V800 PoE version; needs a switch, router or hub that is IEEE 802.3af compliant p. 201, 202
Network settings
IP address, subnet mask and gateway set at the keypad, or DHCP p. 121, 122, 123
Rugged Edition
Portable industrial version with a battery giving at least 12 hours per charge, from vehicle power or an outlet p. 117, 121
Mounting
Wall mounting plate with four holes; mounting screws included p. 119
Clock ID
Up to 10 digits, set at the clock keypad p. 118
Upload schedules
On Demand Ethernet clock: Every Midnight, 9, 1 & 6:00, Manual Only, Real Time or On Demand p. 173

What this manual walks you through

  • Mounting the clock and connecting power and the communications cable p. 119, 120
  • Telling a straight-through network cable from a crossover cable p. 120
  • Charging the Rugged Edition battery p. 121
  • Setting the IP address, subnet mask, gateway and DHCP at the clock keypad p. 121, 122, 123
  • Configuring the wireless clock p. 123, 124
  • Creating a V800 clock profile in TimeForce p. 130, 131
  • Setting the push server IP and upload times on an On Demand Ethernet clock p. 171, 172, 173
  • Troubleshooting serial and Ethernet clock communication p. 181, 184
  • Installing and identifying a PoE clock p. 201, 202
  • Serial cable lengths and the DB9 to RJ12 pinout p. 219, 220

Good to know

  • Power surges can permanently damage the clock; a battery backup or surge protector is highly recommended. p. 119
  • An On Demand clock cannot take a static IP address; with DHCP its address may change each time power is cycled. p. 121
  • Communication beyond 100 feet from the access point is not assured, even where an access point advertises up to 1000 feet. p. 123
  • Serial clocks: the cable from the computer to the master clock must not exceed 200 feet; cables over 20 feet should be shielded and unspliced. p. 219
  • Modem clocks need a two wire phone cable, not a standard four wire cable, to avoid damage to the clock. p. 222

Questions this manual answers

Does the Qqest V800 time clock use swipe cards?

No. Velocity clocks have no card reader; employees punch by keypad entry and finger ID verification. p. 14

How do I connect a serial V800 clock to a computer?

Plug the RJ-11 end into the right side port on the bottom center of the clock and the 9-pin RS-232 end into a serial port; a Keyspan USB to serial adapter also works. p. 120

What port does a V800 Ethernet clock use over a WAN?

Port 5402 must be open; Velocity series clocks use TCP. p. 184

Can the V800 be powered over Ethernet?

Yes, a V800 PoE version exists; it needs a PoE switch, router or hub that is IEEE 802.3af compliant. p. 201, 202

How long does the V800 Rugged Edition battery last?

At least 12 hours per charge; charge it 24 hours before first use and overnight after daily use. p. 121

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Introduction13
  2. Installing the ClockLink Utility15
    1. Program Installation15
    2. Logging In16
  3. Clock Server17
    1. Installing the Clock Server17
    2. Setting Up the Clock Server19
  4. Determining Your Clock Model23
    1. Clock Codes23
  5. ETC 100 Model Clock29
    1. Creating a Time Clock Profile29
    2. Hardware Installation30
    3. Uploading the Date and Time33
    4. Time Clock Usage Instructions34
  6. IntelliClock Setup Instructions35
    1. Creating a Time Clock Profile35
    2. Hardware Installation38
    3. Uploading the Date and Time45
  7. Using the Model IQ 300, 400 or 500 IntelliClock47
    1. Collecting Data47
    2. Additional Features55
  8. Using the Model IQ 1000 IntelliClock63
    1. Creating an IQ 1000 Clock Profile63
    2. Customizing Time Clock Information66
    3. Using the IQ 1000 Clock79
    4. Live Lookup106
    5. Adjust Display Contrast110
    6. Reboot Sequence110
    7. Enter Date and Time Screen110
    8. IQ 1000 Battery Backup Pack111
    9. On Demand Ethernet Settings112
  9. Velocity Clocks117
    1. How Do I Find the V800 / V850 Clock ID and Password?117
    2. Hardware Installation119
    3. Uploading the Date and Time129
    4. V800 Clock Usage Instructions130
    5. Collecting Data139
    6. V850 Clock Usage Instructions140
    7. Creating a Clock Profile140
44 more lines, from page 143 on
  1. Customizing Time Clock Information143
    1. Collecting Data153
    2. Additional Clock Features159
    3. Personal Clock Interface170
    4. V800 / V850 On Demand Ethernet Clock171
  2. Downloading Your Time Clock175
    1. Setting Up a Scheduled Clock Download175
  3. Clock Communication Troubleshooting181
    1. Serial Clock Troubleshooting181
    2. Modem Clock Troubleshooting182
    3. Ethernet Clock Troubleshooting184
  4. Installing a Bell/Buzzer185
    1. ETC Clocks185
    2. IQ Clocks190
  5. Installing an External Door Security Reader197
    1. Introduction197
    2. Before You Install the Reader198
    3. Installing the Reader198
  6. PoE Clocks201
    1. Clock Models201
    2. Specifications201
    3. Clock Installation201
    4. Identifying a PoE Clock202
  7. Static Discharge Plate203
    1. Installing the Static Discharge Plate203
  8. Fingerprint Sensor Security Guard205
    1. WARNING:205
  9. Finger Enrollment Station207
    1. Hardware Installation207
    2. Software Installation208
    3. Enrollment Station Utility Login209
    4. Using the Enrollment Station210
    5. Creating a Finger Template214
    6. Viewing a Template Image216
    7. Common Error Messages217
  10. Cable Specifications219
    1. Serial Clocks219
    2. Modem Clocks222
    3. Ethernet Clocks222
  11. How Do I Create Clock Groups?223
  12. Finger ID Sensor Cleaning Instructions225
    1. Cleaning the Finger ID Sensor225
    2. Caring for the Finger ID Sensor226
  13. Index227

From the PDF’s own bookmarks.

The whole text · 30 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. Table of Contents5-12
  3. Pages 13 to 1613-16
  4. Clock Server17-22
  5. Determining Your Clock Model23-28
  6. ETC 100 Model Clock29-34
  7. IntelliClock Setup Instructions35-46
  8. Using the Model IQ 300, 400 or 500 IntelliClock, pages 47 to 5447-54
  9. Using the Model IQ 300, 400 or 500 IntelliClock, pages 55 to 6255-62
  10. Using the Model IQ 1000 IntelliClock, pages 63 to 7163-71
  11. Using the Model IQ 1000 IntelliClock, pages 72 to 8072-80
  12. Using the Model IQ 1000 IntelliClock, pages 81 to 8981-89
  13. Using the Model IQ 1000 IntelliClock, pages 90 to 9890-98
  14. Using the Model IQ 1000 IntelliClock, pages 99 to 10799-107
  15. Using the Model IQ 1000 IntelliClock, pages 108 to 116108-116
  16. Velocity Clocks, pages 117 to 126117-126
  17. Velocity Clocks, pages 127 to 136127-136
  18. Velocity Clocks, pages 137 to 146137-146
  19. Velocity Clocks, pages 147 to 156147-156
  20. Velocity Clocks, pages 157 to 166157-166
  21. Velocity Clocks, pages 167 to 174167-174
  22. Downloading Your Time Clock175-180
  23. Clock Communication Troubleshooting181-184
  24. Installing a Bell/Buzzer185-196
  25. Installing an External Door Security Reader197-200
  26. Pages 201 to 204201-204
  27. Pages 205 to 218205-218
  28. Cable Specifications219-222
  29. Pages 223 to 226223-226
  30. Index227-234

The file

Revision and size

RevisionCompiled Date: September 13, 2011
PublisherQqest Software Systems, Inc.
Pages234
PDF1.1 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 234

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 234
Page 2
Page 2of 234
Page 3
Page 3of 234

More documents · 1

For the same models