Time Force II Hardware Guide: Installing an External Door Security Reader

Pages 197 to 200 of 234, from Time Force II Hardware Guide

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Qqest V800

Page 197

TimeForce II Hardware Guide

185

Installing an External Door Security Reader Introduction The Door Security feature of a Qqest time clock allows you to connect the clock relay to an external door switch (or, Wiegand reader). When an employee’s punch at the time clock is accepted, the relay activates and the door opens. External Wiegand readers (either Qqest or HID) connect to the clock via a 3 or 4 contact screw terminal. There may be either 3 or 4 wires used from the external reader, depending on the version of your time clock motherboard.

Table HARDWARE-3: Wiegand Contacts Signal

Wire Color

Description

Data1

White

Data from reader to clock

Data0

Green

Data from reader to clock

Ground

Black/Bare Shield Wire

Power and data ground

VCC

Red

Power (not present on earlier board versions)

Wires of any other color should be trimmed so that no bare wire shows, and then taped or tie-wrapped so that they do not contact any other wire or metal, such as conduit or door frames.

Installing an External Door Security Reader

Page 198

186

Qqest Software Systems, Inc.

Before You Install the Reader The external reader should be mounted in the correct location before connecting it to the time clock. Mount at shoulder-height if cards are normally worn around the neck on a lanyard. Mount at hip-height if cards are activated “hands-free” by bringing the hip containing the card holder (i.e., wallet) close to the reader. The wires from the reader must be long enough to reach from the reader to the clock. The wires may be extended up to 100 feet total length, although you must be cautious to ensure that longer wire runs are routed away from electrical noise sources such as power lines, motors, florescent lights, etc.

Installing the Reader The following instructions will walk you through connecting your external door security reader to the time clock. Note: Power should be removed from the clock before connecting the reader wires. 1.

Remove the clock from the wall (if it has already been mounted), turn it over and examine the back. At the bottom of the clock case a panel is cut out, revealing the hardware components on the inside of the clock. The Wiegand connector is located directly to the right of the RJ11 (telephone-type) “WAND” connector. See Figure HARDWARE-7.

Page 199

TimeForce II Hardware Guide

187

Figure HARDWARE-7: Wiegand Connector 2.

The connections on the Wiegand port are (from left to right) “Data1,” “Data0,” “Ground,” and “VCC (Power).” See page 185 for a table detailing which colored wires are to be installed into which ports.

3.

Connect the data wires into the screw terminals.

4.

On the “Ground” wire, twist the black and shield wires together and insert into the appropriate terminal.

5.

Finally, connect the red power wire. Note: Boards with 3-terminal Wiegand connectors will still function when connected to the clock, but must be connected it an external power supply. 4-terminal clocks are capable of powering the reader with no external connections beyond the clock and reader.

Once the door security unit has been connected you can re-mount the clock on the wall and re-connect its data and power cables.

Installing an External Door Security Reader

Page 200

188

Qqest Software Systems, Inc.