Page 108
96
Qqest Software Systems, Inc.
3.
In the TimeForce Server field, enter the name of the machine or IIS webserver that hosts the TimeForce website. If the Live Lookup Server is installed on the same machine as the TimeForce system, enter “http://localhost” into this field.
4.
In the Username field, enter the login user name of an administrator-level TimeForce user.
5.
In the Password field, enter the login password for the above specified user.
6.
Enter the Company Code that all users must enter when logging into the TimeForce system.
7.
Click on the icon to save the changes that you have made. The server logs into the TimeForce database.
8.
You can now click on the icon to close the Live Lookup Server window. The program remains running in the Windows System Tray.
Note: In order to use Live Lookup functionality, the Live Lookup Server must be running.
Configuring the Time Clock Before you can use Live Lookup options, you must first specify the IP address of the machine that is hosting the Live Lookup Server. The following procedures are performed at the time clock itself. 1.
At the clock, press the <MENU> button and log into the Administrator clock options.
2.
Select #1 for SYSTEM MAINT.
3.
Select #3 for ETHERNET.
4.
Select #4 for SET LIVE SERVER.
5.
Enter the IP address of the machine that is hosting the Live Lookup Server. Remember to use the period [ . ] key.
6.
Press the <ENTER> button to save the changes that you have made.
You should now be able to access Live Lookup options from the time clock.
Page 109
TimeForce II Hardware Guide
97
Using Live Lookup Options The following instructions walk you through using Live Lookup options at the time clock. 1.
Press the <MENU> button on the clock keypad, and select the PERSONAL option.
2.
Enter your Card # using the number keys on the clock keypad and press <ENTER>.
3.
Enter your assigned PIN and press <ENTER>. The main “Personal Options” menu opens.
4.
Press 5 for “Live Lookup.” The following message appears: CONNECTING TO SERVER --PLEASE WAIT--
5.
Once communication with the Live Lookup Server has been established, the main “Live Lookup” menu opens.
6.
Press 1 for “Hours” in order to view your current hours information.
7.
The following options appear: • • •
Yesterday: Select this option to view the number of total hours worked on the previous day. Week: Select this option to view the total number of hours assigned to you for the current work week. Pay Period: This option displays the total number of hours assigned to you for the current pay period.
View hours information as desired. Press the button located below the “BACK” option to return to the main Live Lookup screen. When you have finished viewing hours information, press the button located under the “DONE” option to disconnect from the Live Lookup Server.
Using the Model IQ 1000 IntelliClock
Page 110
98
Qqest Software Systems, Inc.
Adjust Display Contrast The IQ 1000 is equipped with a control which allows you to adjust the contrast of the main clock display screen. 1.
Remove the time clock from the wall (if mounted). The contrast control is located on the back of the clock.
2.
Turn the clock over and examine the back of the clock case. At the top of the case are two horizontal slots used to attach the clock to the mounting panel. Directly below the horizontal slot on the left is a cut-out hole. This is the contrast control.
3.
Insert a small screwdriver (either phillips or flathead) into the hole, and adjust the display contrast as desired.
Reboot Sequence If for some reason you need to reboot your IQ 1000, this action can be performed by pressing a sequence of keys at the clock keypad. This sequence is <MENU>, < 7 > and <ENTER>. This option is useful for when rebooting is necessary on a clock that is mounted with no access to the power adapter.
Enter Date and Time Screen If for some reason your time clock loses the stored date and time, the “Enter Date and Time” screen appears. The following prompt appears on the clock display: CURR DATE: XX/XX/XXXX MONTH: •
• •
Enter a number between 1 and 12 to denote the desired month and press <ENTER>. “DAY” appears below the specified month setting. Enter the desired date and press <ENTER>. “YEAR” appears below the specified day setting. Enter the desired year and press <ENTER>.
Page 111
TimeForce II Hardware Guide
99
The current time is displayed at the top of the screen. The following prompt appears: ENTER TIME AS hhmmss In 24-hour format, enter the desired time as “HH/MM/SS” and press <ENTER>. For example, a time of four o’clock p.m. would be entered as “160000.” The date and time setting is saved, and the clock returns to its normal state.
IQ 1000 Battery Backup Pack The IQ 1000 Battery Backup Pack allows you to connect an external power supply to your time clock so that in the event of a power outage, the clock will remain functional. The backup pack will keep your clock running for a minimum of 2 hours. Once the clock’s main power is restored, the battery pack will automatically recharge. Once the battery pack is drained of power, it takes 16 hours to fully recharge.
Connecting the Battery Backup Pack The battery backup pack plugs into the 6-prong plug located on the back of the IQ 1000, next to the “Phone/Computer/Daisy” port. The word “Battery” appears at the base of the plug on the clock board. Insert the battery backup connector into the battery port and press firmly until the connector snaps into place. The backup pack itself can then be placed behind the time clock in the IQ 1000 mounting bracket. The clock snaps into place over the backup pack.
Using the Model IQ 1000 IntelliClock
Page 112
100
Qqest Software Systems, Inc.
LED Status Light A red LED status light appears on the battery pack, located on the righthand side of the backup pack board. This light will inform you of the status of your backup pack. • • •
When the battery pack is fully charged and not in use, the status light is off. When charging, the status light is on. When the battery backup is in use, the status light will be off.
On Demand Ethernet Settings The IQ 1000 On Demand clock uploads its stored data to the Clock Server automatically. This makes the process manually connecting to your time clock for the purpose of downloading its stored punches unnecessary. The clock automatically uploads any stored data to the Clock Server immediately upon its entry into the clock. Manual data upload can also be selected. Note: The following setup instructions are specific to the Push Clock options. All other ethernet setup steps are identical to the IQ 1000 Ethernet clock.
Setting the IP Address The time clock uploads its data to the Clock Server software. Before your clock will be able to successfully transfer punches, you must first enter the IP Address. Note: See page 5 for instructions on setting up the Clock Server. You may have chosen to use a Clock Server hosted by Qqest. In this case, the server IP should have been supplied to you at the time of purchase. 1.
From the keypad of the clock, press the <MENU> button and select “ADMIN.”
Page 113
TimeForce II Hardware Guide
101
2.
Enter your card number and password. The Main Menu appears. Note: The default administrator username is “8888.” The default admin password is “1111.”
3.
Select 1 for “SYSTEM MAINT.”
4.
Select 6 for “OUTBOUND OPTIONS.”
5.
Select 3 for “ENTER SERVER IP.”
6.
From the keypad of the clock, enter the IP address of the Push Server. Remember to use the period [ . ] key. Once the IP has been entered, press <ENTER>. The “Port” screen appears.
7.
Enter the port number at the clock keypad. Press the upper-right soft key to automatically populate this setting with the default of “5705.” Note: In most cases, the default setting will be used.
8.
Press the <ENTER> key to save the changes that you have made. You can now exit the clock menu.
Set Call Times The time clock allows you to specify how stored punches are uploaded to the database. 1.
From the keypad of the clock, press the <MENU> button and select “ADMIN.”
2.
Enter your card number and password. The Main Menu appears. Note: The default administrator username is “8888.” The default admin password is “1111.”
3.
Select 1 for “SYSTEM MAINT.”
4.
Select 6 for “OUTBOUND OPTIONS.”
5.
Select 1 for “SET CALL TIME(S).”
6.
The “Set Dial Times” screen opens. The following options are available:
Using the Model IQ 1000 IntelliClock
Page 114
102
Qqest Software Systems, Inc.
1. EVERY MIDNIGHT 2. 9, 1, & 6:00 3. MANUAL ONLY 4. REAL TIME 5. ONDEMAND •
•
•
• •
Every Midnight: With this option selected, all of the punches accumulated during the day will be uploaded to the Clock Server at 12:00 am. 9, 1, & 6:00: Use this option to upload punches during “off peak” times. This option is intended to upload punches when fewer employees will be actively clocking in and out. Punches will be uploaded at 9:00 am, 1:00 pm, and 6:00 pm. Manual Only: With this option selected, the clock will not automatically upload its stored punches. The punches will remain in the clock until a manual upload is initiated. Note: See the section below for instructions on manually uploading your time clock. Real Time: With this option enabled, all punches entered at the clock will be immediately uploaded to the Clock Server. On Demand: This option is only available with the Ethernet and Cellular clocks. When enabled, the clock will capture the employee’s card number at the clock and query the On Demand server to see if the employee exists in its database. If so, the employee will be allowed to continue with the punch procedure. When the punch process is complete, the resulting punch will be immediately transferred to the On Demand server.
You can now exit the clock menu by pressing <CLR> repeatedly until you are brought back to the displayed time.
Initiating a Manual Upload The clock can be manually uploaded from the main “Outbound Options” menu. 1.
From the keypad of the clock, press the <MENU> button and select “ADMIN.”
Page 115
TimeForce II Hardware Guide
103
2.
Enter your card number and password. The Main Menu appears. Note: The default administrator username is “8888.” The default admin password is “1111.”
3.
Select 1 for “SYSTEM MAINT.”
4.
Select 7 for “UPLOAD DATA.”
The time clock initiates communication with the Clock Server and uploads its time and attendance data. Note: You can also manually upload data by pressing the following combination of keys at the clock keypad: <MENU>, < 9 > and then <ENTER>.
Using the Model IQ 1000 IntelliClock
Page 116
104
Qqest Software Systems, Inc.