Page 99
TimeForce II Hardware Guide
87
TABLE: Hardware-2: IQ 1000 Clock Options Number
Name
Description
Lunch Punch Restriction
With this option enabled and configured on a peremployee basis in TimeForce, the clock will track when the employee clocks out for a lunch break, and will require the employee to take the specified amount of time for lunch before being allowed to clock back in.
Security
This option allows you to enable or disable the Door Security feature. The Door Relay on the time clock can be connected to an external Door Security switch. When an employee’s punch is accepted at the time clock, the relay activates, and the door is opened for a pre-determined number of seconds.
Wiegand Out
This option is used to specify the Wiegand format the clock outputs to an external Wiegand device such as a security system. Note: This option is mutually exclusive with option #36. Both cannot be enabled simultaneously.
15
Quick Punch
This option enables/disables the Quick Punch feature. When enabled, employees do not have to press the final <ENTER> when punching at the clock. This feature is intended to allow very fast Time and Attendance punching when additional information is not required. Enabling this option automatically disables the <JOB>, <TASK>, <QTY>, <DEPT>, and <TIPS> keys.
18
Card Reader Type
This option configures the card reader to read either magstripe or barcode time cards. Select the appropriate setting and press the <ENTER> key. Note: See related option #2 above.
HID26 Decode
This option is used with a Proximity Card Reader to extract an HID 26-bit pattern that will represent an employee Card Number. The decoding properties of this option are mutually exclusive with other decoding format options.
Job Restriction
This option allows you to restrict Jobs at the time clock. With this option enabled, the time clock will only accept Job Numbers that have been sent to the time clock from the TimeForce II program. All other Job Numbers will be rejected. Disable this option to accept all Job Numbers.
12
13
14
19
20
Using the Model IQ 1000 IntelliClock
Page 100
88
Qqest Software Systems, Inc.
TABLE: Hardware-2: IQ 1000 Clock Options Number
Name
Description
Task Restriction
This option allows you to restrict Tasks at the time clock. With this option enabled, the time clock will only accept Task Numbers that have been sent to the clock from the TimeForce II system. All other numbers will be rejected. Disable this option to accept all Task Numbers.
Dept Restriction
This option allows you to restrict Departments at the time clock. With this option enabled, the time clock will only accept Department Numbers that have been sent to the clock from the TimeForce II system. All other numbers will be rejected. Disable this option to accept all Department Numbers.
Time Correction
When enabled, this option disables Relay Events and Door Security and uses relay closure to synchronize electronic time clocks to IQ time using 3-wire synchronization. Minute synchronization will occur each hour at 58 minutes past the hour. Hour synchronization will occur at 5:58 AM and PM.
Receipt Print
With this option selected, a reciept will be printed for each successful punch. This option should only be enabled when using a printer attached to the clock. Excessive wait times will occur if this option is not disabled when no printer is in use. Note: When using this feature, System Option #3 must also be enabled.
Track1 Decoding
Enables decoding of magstripe data as track 1 (7-bit) data instead of track 2 (5-bit) data. Note: This option is mutually exclusive with other decode format options.
26
Zonar Decoding
Enables the retrieval of Binary Coded Decimal data (or Zonar Decoding) on a time card (magstripe or Proximity). Note: This option is mutually exclusive with other decode format options.
27
CIC Magstripe Decoding
Enables decoding of CIC-encoded HID Proximity cards (37-bit Wiegand). Note: This option is mutually exclusive with other decode format options.
21
22
23
24
25
Page 101
TimeForce II Hardware Guide
89
TABLE: Hardware-2: IQ 1000 Clock Options Number
Name
Description
Auto Entry
When enabled, a MIN number of card digits is selected. When the MIN number is entered at the clock by a user, the clock will act as if the final <ENTER> key has been pressed and accept or reject the punch.
30
EMP Not In Clock
This option allows you to select whether an employee that has not been uploaded to the time clock will use the clock’s default schedules, or will be notified that a supervisor override is required to successfully punch at the clock. Note: This option may not be used in conjunction with option #37.
31
FP Required for Menus
When enabled, the clock requires finger template verification for access to clock menus. Note: This option is only used when Finger Template Verification is enabled (option #11).
32
Alpha Chars in Barcode
When enabled, a barcode scan may consist of a combination of numeric and alphabetic characters. When disabled, the barcode scan must consist of numeric characters only.
34
Lunch/Break Keys
This option enables the <LUNCH> and <BREAK> keys on the clock keypad. Press the button located under [YES] to enabled the option, and the button located under [NO] to disable it.
35
Barcode Concatenation
This option enables the reading of multiple barcodes and combines them into a single number (10 character limitation on entire read).
36
Wiegand Input
With this option enabled, the clock will recognize Wiegand input for Card Number entry.
Door Open on Card Entry
If Door Security (option #13) is selected, and the option is enabled for the employee in TimeForce, this option will open the door immediately after the card number entry (as opposed to waiting for the full completion of the punch). This allows for the use of an external card reader, while still being able to input Job Tracking information. Note: This option cannot be used in conjunction with option #31.
29
37
Using the Model IQ 1000 IntelliClock
Page 102
90
Qqest Software Systems, Inc.
TABLE: Hardware-2: IQ 1000 Clock Options Number
Name
38
HID 10302 37-Bit Decode
This option decodes HID 37-BIT Binary cards, and is mutually exclusive with other decode formats.
39
HID 10320 37-Bit Decode
This option decodes HID 37-BIT Binary Coded Decimal cards, and is mutually exclusive with other decode formats.
40
Print Details
When using a receipt printer, this option enables the printing of punch details such as job number, task number, quantity and disbursement amounts, etc. (See option #24)
41
Ignore Supervisor Required
When selected, the clock will not display the “Supervisor Required” message on schedule violations (for employees not in the clock, use option #30). This allows for logging out-of-schedule access without any delay for systems with external readers. The clock generates a supervisor override punch with a supervisor ID of “9999999999.”
42
Qqest 40-Bit Decode
This option allows for the decoding of external Wiegand cards as straight binary (no parity bits), and is mutually exclusive with other decode formats.
43
Ext. Reader Door Only
With this option enabled, a swipe generated from an external Wiegand reader will open a door only. No time and attendance data is collected.
45
Disable Tones
When selected, the tone emitted by the clock on the accepting of a punch is disabled. Note: Error tones cannot be disabled. Key-click tones are enabled/disabled by option #4.
46
Enable Debug
When enabled, debug logging messages are collected and sent to the Serial Port.
Power Save
When selected, the clock will disable electrical power to the LED display backlight and finger template reader after a period of 15 seconds inactivity. This is done to conserve electricity. Power to both items will be restored instantly upon user interaction with the clock.
47
Description
Page 103
TimeForce II Hardware Guide
91
TABLE: Hardware-2: IQ 1000 Clock Options Number
Name
Description
49
Door External Only
The TimeForce system allows you to specify that finger template verification is not required for certain employees. With this clock option enabled, those employes will be granted door access with no finger template verification, while still enforcing verification for others.
50
In/Out Keys Required
When enabled, the clock requires the use of the <IN> and <OUT> keys on the clock keypad before a punch is accepted.
51
Cell Provider
For IQ 1000 Cellular clocks only, this option is used to choose the “Cellular Network Access Provider” (AT&T, TMobile) that is used to gain cell network access for the clock.
52
Custom Wiegand
This option is used with Wiegand card readers, and allows the user to specify how the collected bit patterns (data) read from time cards will be interpreted by the clock.
GPRS Static IP
For use with GPRS Cell clocks only, this option is used to enable or disable the Static IP feature built into GPRS SIMM cards that are equipped with “special” network programming. The Static IP SIMM card feature allows users to upload information (such as profiles and finger templates) to the clock using the ClockLink utility.
DHCP
When enabled, Ethernet equipped clocks will query the World Wide Network for an IP address that the clock will use for communicating on the network. Note: Each time the clock is power-cycled it will request and may receive a different IP address. With this option disabled, Ethernet equipped clocks must be given a static IP address from within the clock’s menu.
Cache Preferred
With this option enabled, the clock will first look in its own memory files for employees clocking in or out. If the employee cannot be found in the clock memory, employee information will be requested from the On Demand server.
53
54
56
Using the Model IQ 1000 IntelliClock
Page 104
92
Qqest Software Systems, Inc.
TABLE: Hardware-2: IQ 1000 Clock Options Number
Name
Description
57
Enforce Password
When enabled, the password sent by the ClockLink or Clock Server utilities at login will be evaluated. The login will be denied if the password does not match the password stored in the clock. With this option disabled, any password sent by ClockLink or Clock Server will be accepted. Note: ClockLink and Clock Server must still attempt the password to gain login access.
58
Job Required
When enabled, the clock requires the user to enter a job number using the <JOB> key on the clock keypad before a punch will be accepted.
59
Qty Required
When enabled, the clock requires the user to enter a quantity amount using the <QTY> key on the clock keypad before a punch will be accepted.
60
Task Required
When enabled, the clock requires the user to enter a task number using the <TASK> key on the clock keypad before a punch will be accepted.
61
Dept Required
When enabled, the clock requires the user to enter a department number using the <DEPT> key on the clock keypad before a punch will be accepted.
Break Punch
With this option enabled and configured on a peremployee basis in TimeForce, the clock will track when the employee clocks out for a break, and will require the employee to take the specified amount of time before being allowed to clock back in.
62
Clock Passcode This is the clock password that the ClockLink uses to communicate with the IQ 1000. You must supply ClockLink with the correct password before you will be able to communicate with your time clock.
Page 105
TimeForce II Hardware Guide
93
When you select this option the following message appears: NEW ALPHA PASSCODE IN=QUIT OUT=DONE IQ1000 <<PREV NEXT>> Enter the desired passcode and press the <OUT> key. Select [YES] to keep the changes that you have made, or [NO] to reject the changes and keep the previous passcode. The default clock passcode is “IQ1000.” Note: When changing this setting, remember that it must also be changed in the Time Clock Profile. See “How Do I Find the Clock Number and Password?” on page 65 for instructions on entering the clock password. Clock Information This screen displays the various settings that you have selected for your time clock. Press any key to return to the main menu.
Personal Clock Interface When you select “Personal,” and enter your card number and password, the Main Menu appears with the following options: 1. VALID PUNCH TIMES 2. ACCRUALS 3. DEPT, PERS. 4. FIND PUNCHES 5. LIVE LOOKUP Type in the number for the option you wish to access. Press the <CLR> button to return to the previous menu from any point in the clock menu options. Note: The “Live Lookup” option is only available on IQ 1000 clocks with a communication type of “Ethernet” or “Wireless.” See page 94 for more information on setting up and using Live Lookup. Valid Punch Times Select this option to view the window of time during which you are allowed to punch at the time clock. This option is used when the administrator user has set up restricted times within the IQ 1000. Press any key to return to the main menu. Using the Model IQ 1000 IntelliClock
Page 106
94
Qqest Software Systems, Inc.
Accruals Select this option to view the number of “Sick” and “Vacation” hours that you currently have available. Press any key to return to the main menu. Department and Personal This menu option displays your default department level. For Administrators, Supervisors, and Team Leaders the “Class” setting that is assigned to the user in their employee profile is also shown. The Class setting defines your level of access rights to the time clock and its functions. Employee messages are also displayed on this screen. Find Punches This option allows you to view your punches that are currently being stored by the clock. Use the gray buttons located directly below the clock display to scroll to the “Previous” and “Next” punches. See “Downloading Your Time Clock” on page 163 for instructions on downloading the punches from your time clock.
Live Lookup The Live Lookup option connects your IQ 1000 to the TimeForce database via the Live Lookup Server software. This allows your employees to access current hours information directly from the clock itself. Note: Live Lookup is only available on IQ 1000 time clocks with a communication type of “Ethernet” or “Wireless.” “Serial” and “Modem” clocks do not support this feature.
Installing the Live Lookup Server The installation for the Live Lookup Server is located on the main TimeForce installation disk. 1.
Insert the TimeForce disk into your computer’s CD-ROM drive. The main Installation Menu appears.
2.
From the main Installation Menu, click on the [UTILITIES] icon, and then on [IQ 1000 LIVE LOOKUP].
Page 107
TimeForce II Hardware Guide
95
3.
A message box appears which reads “This will install Live Lookup for TimeForce. Do you wish to continue?” Click on the [YES] icon. The InstallShield Wizard opens and guides you through the rest of the installation process.
4.
The InstallShield Wizard opens with a “Welcome” screen. Click on the [NEXT] icon to continue.
5.
The “Destination Directory” screen opens. The default installation directory for the Live Lookup Server is “C:\Program Files\Qqest Software Systems\TimeForce.” If you would like to select a custom install directory, click on the [BROWSE] icon. Click on the [NEXT] icon to continue. Note: It is recommended that you allow the program to install to its default location.
6.
The “Program Folders” screen opens. Select the folder in the Windows Start Menu where you would like the program icons to be created. The default folder is “TimeForce/Live Lookup.” Click on the [NEXT] icon to continue.
7.
The selected installation settings are displayed. Review the specified settings and click on the [BACK] icon to make any necessary changes. Click on the [NEXT] icon to begin the program installation.
8.
Once the installation has completed, click on the [FINISH] icon to exit the InstallShield Wizard.
9.
From the TimeForce “Utilities” menu, click on the [RETURN TO MAIN MENU] icon, and then on [EXIT].
Configuring the Server The following instructions walk you through configuring the Live Lookup Server to connect to the TimeForce database. 1.
From the Windows Start Menu, go to Programs | TimeForce | Live Lookup and click on “Live Lookup.” The Live Lookup Server opens.
2.
Click on the screen.
icon in the top left-hand corner of the
Using the Model IQ 1000 IntelliClock