The text of a manual · part 13 of 30
Time Force II Hardware Guide: Using the Model IQ 1000 IntelliClock, pages 90 to 98
Pages 90 to 98 of 234, from Time Force II Hardware Guide
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Qqest V800
Page 90
78
Qqest Software Systems, Inc.
Other Punch Options After the card number has been specified, press <ENTER> to enter the punch and have the software determine whether it is an in or out punch. If you wish to assign the punch a type, press the <IN>, <LUNCH>, <BREAK>, or <OUT> buttons, then press <ENTER>. You can press the buttons in combination to specify a punch type; for example, <LUNCH> plus <OUT>, or <BREAK> plus <IN>. If you make a mistake, such as accidently pressing <IN> rather than <OUT>, simply press the correct button and the display shows the new punch type you’ve specified. When the punch type is correct, press <ENTER>. Unless you have enabled the clock’s Quick Punch feature, you should always press <ENTER> to complete a punch entry at the IQ 1000. See “System Options” on page 85 for more information.
Additional Clock Features The IQ 1000 includes many advanced features. The following is a brief description of the features offered by this line of clocks. Press the <MENU> button to see the additional clock options. The clock includes two different methods of user interface, “ADMIN,” and “PERSONAL.” • •
The ADMIN user interface allows administrator users unlimited access to the time clock and its options. The PERSONAL user interface allows employees to log into the time clock and view their individual personal settings.
A user’s level of access to the time clock and its functions is defined by the “Class” that the user is set up with in their TimeForce employee profile.
Admin Clock Interface When you select “Admin,” and enter your card number and password, the Main Menu appears with the following options: Note: The default clock administrator username is “8888.” The default admin password is “1111.”
Page 91
TimeForce II Hardware Guide
79
1. SYSTEM MAINT 2. SYSTEM OPTIONS 3. CLOCK PASSCODE 4. CLOCK INFORMATION Type in the number for the option you wish to access. Note: Press the <CLR> button to return to the previous menu from any point in the clock Menu options. System Maintenance The System Maintenance menu has five options: 1. REPORTS 2. MEMORY 3. ETHERNET 4. FINGER ID 5. SET DATE/TIME 6. OUTBOUND OPTIONS 7. UPLOAD DATA Type in the number for the option you wish to access. Reports The Reports menu has three options: 1. STORAGE USED 2. SYSTEM VER. & DATES 3. COMPANY INFORMATION 4. FINGER ID VERSION 5. DEFAULT SCHEDULES Type in the number for the report you wish to view. The information you request appears in the display menu. After a few seconds, the screen clears and the display returns to the Reports menu. Press the <MENU> button to return to the System Maintenance menu.
Using the Model IQ 1000 IntelliClock
Page 92
80
Qqest Software Systems, Inc.
Memory The Memory Menu has three options: 1. CLEAR DATA MEMORY 2. SET TO DEFAULTS 3. SET CLOCK ID 4. SCAN DATA MEMORY 5. CLEAR EMP, TIMES 6. SET GLOBAL TIMEOUT Type in the number for the option you wish to access. Clear Data Memory This option deletes all data that is currently stored in the clock. When you select this option, you receive the following prompt: THIS WILL DELETE *ALL* DATA IN THE CLOCK AND IS ** IRREVERSIBLE!** ARE YOU SURE?? YES NO The <NO> and <YES> buttons are the two gray rectangular buttons above the numeric keypad on the clock face. The button on the left is the <NO> button and the one on the right is the <YES> button. Press the appropriate response. This option is restricted for security purposes. A menu will appear asking you to enter a passcode. To obtain this passcode, call Qqest Technical Support at 1-800-697-7010. Set to Defaults When you select this option, you receive the following prompt: SET TO DEFAULTS ARE YOU SURE? YES NO Press the appropriate response. When you have made a selection, you will be returned to the Memory menu.
Page 93
TimeForce II Hardware Guide
81
Set Clock ID When you select this option, you receive the following prompt: ENTER CLOCK ID CURRENTLY: [X] The Currently field shows the current clock ID. By default, this is 1. To change the clock ID, type in the new ID and press <ENTER>. Scan Data Memory This option scans the data being stored by the time clock looking for data that is outside of its known pointers. If data is found, the pointers are reset to include the found data, making the information available for download. This option is intended for use by Qqest Technical Support. Clear Emp, Times This option clears all information that has been uploaded to the clock from the TimeForce system (such as employees, departments, default schedules, etc.). This option is not reversible. Once deleted, data must be re-uploaded to the clock using the ClockLink program. When you select this option, you receive the following prompt: THIS WILL DELETE ALL COMPANY AND EMPLOYEE INFO AND IS ** IRREVERSABLE! ** CONFIG IS UNCHANGED ARE YOU SURE?? The <NO> and <YES> buttons are the two gray rectangular buttons above the numeric keypad on the clock face. The button on the left is the <NO> button and the one on the right is the <YES> button. This option is restricted for security purposes. A menu will appear asking you to enter a passcode. To obtain this passcode, call Qqest Technical Support at 1-800-697-7010. Set Global Timeout This option allows you to configure the number of seconds for which menus are displayed on the face of the time clock before the clock times out and returns to the main “ready” screen.
Using the Model IQ 1000 IntelliClock
Page 94
82
Qqest Software Systems, Inc.
When you select this option, you receive the following prompt: ENTER GLOBAL TIMEOUT (KEYPRESS WAIT TIME) IN SECONDS: NOW: 20 RANGE 20 - 60 The available range of seconds is 20 through 60. By default, the default timeout is set to 20 seconds. Enter the desired number of seconds at the clock keypad and press <ENTER>. Ethernet This menu contains the clock’s ethernet settings. This menu has four options: 1. SET IP ADDRESS 2. SET SUBNET MASK 3. SET GATEWAY 4. SET LIVE SERVER 5. SET PUSH SERVER 6. WIRELESS SETTINGS 9. SHOW SETTINGS Set IP Address When you select this option, you receive the following prompt: SET NEW IP ADDRESS: CURRENTLY: ENTER NEW IP: The Currently field shows the current IP Address. To change the clock IP address, type in the new address and press <ENTER>. Set Subnet Mask When you select this option, you receive the following prompt: SET NEW SUBNET MASK: CURRENTLY: ENTER NEW MASK:
Page 95
TimeForce II Hardware Guide
83
The Currently field shows the current Subnet Mask. To change the Subnet Mask, type in the new mask and press <ENTER>. Set Gateway When you select this option, you receive the following prompt: SET NEW GATEWAY: CURRENTLY: ENTER NEW GATEWAY: The Currently field shows the current Gateway. To change the Gateway, type in the new setting and press <ENTER>. Set Live Server This option allows you to set the IP address of the server that the time clock connects to when using the Live Lookup option. See page 94 for more instructions. Set Push Server When using the Cellular clock, this option allows you to set the IP address for the server that the clock connects to. See the cell clock documentation for further instructions. Wireless Settings This menu allows you to configure various wireless options. Enter SSID The SSID is the ID of the wireless access point that the clock will connect to. 1.
From the Ethernet Menu, press 6 for “Wireless Settings.”
2.
Press 1 for “Enter SSID.” The following prompt appears: ENTER WIRELESS ID: (SSID) (ALPHANUMERIC ENTRY)
3.
Use the grey buttons above the clock keypad to enter the ID of the wireless access point and press <ENTER>.
Using the Model IQ 1000 IntelliClock
Page 96
84
Qqest Software Systems, Inc.
Connection Type This option lets you configure whether your clock will connect to a wireless access point (infrastructure), or computer-to-clock (AD HOC). Security Settings This option allows you to configure network authentication options. Show Settings This menu displays the clock’s current wireless settings. Show Settings This option displays the clock’s current IP Address, Subnet Mask and Gateway settings. Finger ID This menu contains the time clock’s finger template settings. See “Enrolling Finger Templates” on page 67 for instructions on this menu. Set Date/Time This option allows you to set the date and time on the clock manually from the clock keypad. When you select this option, you receive the following prompt: CURR DATE: XX/XX/XXXX MONTH: •
• •
Enter a number between 1 and 12 to denote the desired month and press <ENTER>. “DAY” appears below the specified month setting. Enter the desired date and press <ENTER>. “YEAR” appears below the specified day setting. Enter the desired year and press <ENTER>.
The current time is displayed at the top of the screen. The following prompt appears: ENTER TIME AS hhmmss In 24-hour format, enter the desired time as “HH/MM/SS” and press <ENTER>. For example, a time of four o’clock p.m. would be entered as “160000.”
Page 97
TimeForce II Hardware Guide
85
The date and time setting is saved, and the clock returns to the main “System Maintenance” menu.
System Options When you select this menu item, the following message appears: SYSTEM OPTIONS ENTER OPTION NUMBER FOLLOWED BY *ENTER* Type in the option number you wish to access. When you do so, you receive a prompt inviting you to change the current setting for this option by pressing the button below [YES] or [NO] on the clock display. Make the desired changes. Press <ENTER> to save your changes and <CLR> to return to the Main Menu. Note: All options are accessible from the System Options screen. However, certain options require additional hardware for use. Options The following table lists the system options that are available on the IQ 1000 equipped with firmware main code revisions 5.0n and above (On Demand application code). Type in the option number then press <ENTER> to access the option.
TABLE: Hardware-2: IQ 1000 Clock Options Number
1
2
Name
Description
Card Key
This option allows keypad entry of employee Card Numbers, making physical time cards unnecessary. Press the key located under [YES] on the clock display to enable this option. Press the key under [NO] to disable.
Barcode
This option allows the use of barcode time cards. Barcodes can always be used for entering Job and Task information, but can only be used as employee time cards with this option enabled. Note: See related option #18.
Using the Model IQ 1000 IntelliClock
Page 98
86
Qqest Software Systems, Inc.
TABLE: Hardware-2: IQ 1000 Clock Options Number
Name
Description
3
Printer
This option is for use when a reciept printer is attached to the time clock. Note: Enabling this option with no printer attached will result in excessive wait times as the time clock attempts to communicate with the non-existent printer.
4
Key Click
With this option enabled, the time clock will emit a short beep each time a key is pressed.
5
Relay Events
When enabled, this option will cause the time clock to check for scheduled Relay Events and activate the Clock Relay when an event time occurs.
Job Key
This option enables or disables the <JOB>, <TASK> and <QTY> keys on the clock keypad. Press the key located under [YES] on the clock display to enable these keys. Press the key under [NO] to disable them.
7
Dept Key
This option enables or disables the <DEPT> key on the clock keypad. Press the key located under [YES] on the clock display to enable this key. Press the key under [NO] to disable it.
8
Tips Key
This option enables or disables the <TIPS> key on the clock keypad. Press the key located under [YES] to enable this key. Press the key under [NO] to disable it.
9
IN/OUT Keys
This option enables or disables the <IN> and <OUT> keys on the clock keypad. Press the button located under [YES] on the clock display to enable these keys. Press the key under [NO] to disable them.
10
US/EURO Date Format
This option allows you to select the format of the date displayed on the time clock. Choose between a US and European date format.
Fingerprint
This option allows you turn finger template verification on or off. When enabled, finger template requirements can be manually disabled on an individual basis from the TimeForce II program. With this option disabled, verification will be disabled for all employees.
6
11