Page 117
TimeForce II Hardware Guide
105
Velocity Clocks Velocity Clock models V800 and V850 are advanced clocks with many options and features. They can be used to restrict employee punching, allowing employees to punch at the clock during their scheduled shift times only. This model also allows your employees to view various information at the clock itself such as accrual totals, scheduled shift times and the date and time of their last clock entry. Rugged Edition Both the V800 and the V850 are available in Rugged Edition. These clocks give you the same features and ease of use as the standard Velocity Clocks, but are designed for portability and use in industrial settings. Before communication with the clock can be established, you must first create a Time Clock Profile in the TimeForce software.
How Do I Find the V800 / V850 Clock ID and Password? The clock ID and password are stored in the time clock itself. These settings can be changed from ClockLink once you have connected to the time clock, but you must specify the clock's current ID and password before a connection can be made. • •
The default ID on a V800 clock is “1.” The default password is “V800.” The default ID on a V850 clock is also “1.” The default password is “V850.”
The following procedures are performed at the keypad of the clock itself.
Velocity Clocks
Page 118
106
Qqest Software Systems, Inc.
Finding the Clock ID 1.
On the clock keypad, press the <MENU> button. Select 1 for “ADMIN.”
2.
The clock prompts you for your card number. Type in a card number with administrator-level access rights and press <ENTER>. Note: The default admin card number is “8888.”
3.
The clock prompts you for a PIN. Enter the appropriate password (based on the card number used) and press <ENTER>. Note: The default admin password is “1111.”
4.
The “Main Admin Menu” appears. Press 3 for “Clock Setup.”
5.
Press 2 for “Clock ID/Pass.”
6.
Press 1 for “Clock ID.”
7.
The “NOW:” field displays the clock's current ID. Enter a new ID if desired and press <ENTER>. Note: The clock ID may be up to 10 digits in length.
You can now exit the time clock menu by pressing <CLR> repeatedly until the time is shown on the clock display.
Finding the Clock Password 1.
On the clock keypad, press the <MENU> button. Select 1 for “ADMIN.”
2.
The clock prompts you for your card number. Type in a card number with administrator-level access rights and press <ENTER>. Note: The default admin card number is “8888.”
3.
The clock prompts you for a PIN. Enter the appropriate password (based on the card number used) and press <ENTER>. Note: The default admin password is “1111.”
4.
The “Main Admin Menu” appears. Press 3 for “Clock Setup.”
5.
Press 2 for “Clock ID/PASS.”
6.
Press 2 for “Passcode.”
7.
The current passcode is displayed. Use the alpha-numeric keypad to enter the passcode you desire. When done, press the <OUT> key. When prompted to save your changes, press [YES].
Page 119
TimeForce II Hardware Guide
107
You can now exit the time clock menu by pressing <CLR> repeatedly until the time is shown on the clock display.
Hardware Installation Use the following instructions to place your time clock in the desired location and to install communications with the clock. Follow the instructions below that correspond with the type of communication that your clock uses. Note: See page page 114 for instructions on installing the V800/V850 Cellular Modem Clock. The clock should be placed in a convenient location where employees typically enter and exit the work area. It includes a mounting plate with four holes. Mounting screws are included. Once the mounting plate is attached to the wall and all cables are connected, the clock’s face can be slid into place and secured to the mounting plate. 1.
The clock is shipped with the mounting plate attached. Remove the mounting plate from the clock and attach it to the wall with the provided mounting screws. The flat side should face to the left, with the rounded side facing to the right. Note: Removing the metal mounting plate from the back of the time clock will not void your hardware warranty.
2.
Connect the power cord to the bottom of the clock and plug it into the closest available electrical (110-120 VAC) outlet. Note: It is highly recommended that you place the time clock on a battery backup or surge protector. Power surges can permanently damage the clock. For instruction on connecting an Ethernet PoE clock, see page 189.
3.
Connect the clock’s communications cable. Use the instructions below that correspond with your clock’s communication type. Ethernet Clocks • The Ethernet port is located in the top center of the back of the clock. Plug one end of the Standard Category 5 (CAT5) cable into the Ethernet port.
Velocity Clocks
Page 120
108
Qqest Software Systems, Inc.
•
Connect the other end of the CAT5 cable to your network. The cable used to connect the clock must be a straight-through cable, not a crossover. To tell the difference between a straightthrough and a crossover cable, hold the connectors side by side, with the same side of each connector facing you. Look at the wires inside of the connector. If the colors of the wires run in identical order from left to right in both connectors, the cable is a straight-through. If the colors run in opposite order, the cable is a crossover.
Serial Clocks • Connect the RJ-11 connector of the cable (the one that looks like a phone-jack) into the right side port on the bottom center of the time clock. • Connect the RS-232 end of the cable (the 9-pin D-Connector) into an available serial port on your computer. Note: Serial clocks can also be connected through a USB port using a Keyspan USB to serial adapter. Modem Clocks • Connect the RJ-11 connector of the cable (the one that looks like a phone-jack) into the right side port on the bottom center of the time clock. • Insert the other RJ-11 connector into an active analog telephone wall-jack. 4.
The clock can now be attached to the mounting plate. Place the top of the clock on the lip at the top of the mounting plate. Slide the clock over the center tab on the bottom of the clock until the center screw hole at the bottom of the clock aligns with the screw hole in the tab. Secure the clock by placing a screw through the aligned hole.
Page 121
TimeForce II Hardware Guide
109
Rugged Edition Battery Charging The battery on a Rugged Edition clock gives you a minimum of 12 hours of operation per-charge, and can be recharged using vehicle power supply, or a standard outlet. The battery should be charged for 24 hours before initial use to ensure that the battery is fully charged. After daily use, charge the battery overnight. The LED charging indicator is lit during the initial 4-hour rapid charge cycle. The battery may still be charging when the LED is not illuminated.
Configuring the Ethernet Clock The Ethernet clock uses Ethernet Settings, an ID and a Password for communication. The Ethernet Settings include an IP Address, Subnet Mask and Gateway. These settings are comparable to giving the clock an “address” at which it can be found over the network. Consult your Network Administrator about acquiring these settings. Note: If the clock is On Demand capable, a static IP address cannot be allocated to it. Enable the Dynamic Host Configuration Protocol (DHCP) option so that an IP address will be automatically set aside for the clock by the network. Please be aware that if using the DHCP option, each time the clocks power is cycled a different IP address may be assigned. 1.
From the clock keypad, press the <MENU> button and select 1 for “ADMIN.”
2.
Enter an administrator ID (or Card #) and press the <ENTER> key. Note: The default administrator ID is “8888.”
3.
Enter the password (or PIN) for the specified administrator ID and press the <ENTER> key. Note: The password for the default admin ID is “1111.”
4.
Press 3 for “Clock Setup.”
5.
Press 1 for “Communication.” The “Ethernet” menu opens.
6.
Press 2 for “IP Address.” The current setting will be displayed, and the clock will prompt you to enter the new setting.
7.
Enter the new setting at the keypad (remember to use the Period key when necessary), and press <ENTER>.
Velocity Clocks
Page 122
110
Qqest Software Systems, Inc.
Important: The Ethernet Settings are specific to your Local Area Network. It is highly recommended that you change the default settings. Qqest Technical Support cannot supply these settings.
Set IP Address From the “Ethernet” menu, press 2 for “IP Address.” The following prompt appears: SET NEW IP ADDRESS: NOW: ENTER NEW IP: The “NOW” field displays the current IP address. To change the clock IP address, type in the new address at the clock keypad (remember to use the period key) and press <ENTER>.
Set Subnet Mask From the “Ethernet” menu, select 3 for “Subnet Mask.” The following prompt appears: SET NEW SUBNET MASK: NOW: ENTER MASK: The “NOW” field shows the current Subnet Mask. To change the mask, type in the new setting at the clock keypad (remember to use the period key) and press <ENTER>.
Set Gateway From the “Ethernet” menu, select 4 for “Set Gateway.” The following prompt appears: SET NEW GATEWAY: NOW: ENTER GATEWAY IP: The “NOW” field shows the current Gateway. To change the Gateway, type in the new setting at the clock keypad (remember to use the period key) and press <ENTER>.
Page 123
TimeForce II Hardware Guide
111
Enable DHCP From the “Ethernet” menu, select 7 for “Enable DHCP.” The following prompt appears: DHCP NOW: *ENTER* WHEN DONE YES NO The “NOW” field shows the current DHCP setting. To enable DHCP press the key located under the [YES] label on the clock display, or the key under the [NO] label to disable. The “NOW” field will show your choice. Press <ENTER> when done, or <CLR> to cancel changes and exit back to the Ethernet menu.
Configuring the Wireless Clock The wireless time clock supports the following communication protocols: 802.11 a and b. The optimum communication range for the wireless time clock is 50 100 feet from the wireless access point. Some wireless access points advertise communication up to 1000 feet. Regardless of this specification, Qqest Software Systems cannot guarantee communication at a distance of over 100 feet. The following settings must be specified before your time clock will communicate: • • • •
IP Address Subnet Mask Gateway SSID
These settings are specific to your network setup. Qqest Software Systems cannot supply these settings. All wireless options are specified from the “Communications” clock menu.
Velocity Clocks
Page 124
112
Qqest Software Systems, Inc.
1.
From the clock keypad, press the <MENU> button and select 1 for “Admin.”
2.
Enter an administrator ID (or Card #) and press the <ENTER> key. Note: The default administrator ID is “8888.”
3.
Enter the password (or PIN) for the entered administrator ID and press the <ENTER> key. Note: The password for the default admin ID is “1111.”
4.
From the Main Admin Menu, press 3 for “Clock Setup.”
5.
Press 1 for “Communications.” The “Wi-Fi” menu opens.This menu contains the time clock’s communications options.
Set IP Address From the “Wi-Fi” menu, select 5 for “IP Address.” The following prompt appears: SET NEW IP ADDRESS: NOW: ENTER NEW IP: The “NOW” field displays the current IP address. To change the clock IP address, type in the new address at the clock keypad (remember to use the period key) and press <ENTER>.
Set Subnet Mask From the “Wi-Fi” menu, select then 6 for “Subnet Mask.” The following prompt appears: SET NEW SUBNET MASK: NOW: ENTER MASK: The “NOW” field shows the current Subnet Mask. To change the mask, type in the new setting at the clock keypad (remember to use the period key) and press <ENTER>.
Page 125
TimeForce II Hardware Guide
113
Set Gateway From the “Wi-Fi” menu, select 7 for “Set Gateway.” The following prompt appears: SET NEW GATEWAY: NOW: ENTER GATEWAY IP: The “NOW” field shows the current Gateway. To change the Gateway, type in the new setting at the clock keypad (remember to use the period key) and press <ENTER>.
Set SSID The SSID is the ID of the wireless access point that the clock will connect to. 1.
From the “Wi-Fi” menu, select 2 for “Set SSID.” The following prompt appears: ENTER WIRELESS ID: IN=QUIT OUT=DONE <<PREV
2.
NEXT>>
Use the clock keypad to enter the ID of the wireless access point and press <OUT>.
Alpha-Numeric Keypad Entry To enter alphabetic characters at the clock keypad, press a number key repeatedly until the desired character appears.
Velocity Clocks
Page 126
114
Qqest Software Systems, Inc.
The keys on the keypad contain the following letters/characters: • • • • • • • • • • •
[ 1 ]: Special characters (#@&?) [ 2 ]: A, B, C [ 3 ]: D, E, F [ 4 ]: G, H, I [ 5 ]: J, K, L [ 6 ]: M, N, O [ 7 ]: P, Q, R, S [ 8 ]: T, U, V [ 9 ]: W, X, Y, Z [ CLR ]: (backspace) [ . ]: (space)
Configuring the Cellular Modem Clock The Cellular Modem Clock is used to collect time & attendance data in an environment where no Ethernet, serial or modem connection is available. The clock uses a cellular connection to a GSM network to communicate. Note: The only mobile phone companies that currently support this type of communication are Cingular, AT&T and T-Mobile. The time clock contains a cellular modem device. A cellular service provider SIM card is installed in the cellular modem, allowing it to access the GSM network for time clock communications. Once a connection has been established, the GSM network changes the communication method from a phone call to an Ethernet connection. The clock provides the GSM network with the IP address and the port to the Qqest hosted server. Once a connection to the server has been established, all further communication between the clock, GSM network and Qqest Server is TCP/IP.