Page 127
TimeForce II Hardware Guide
115
Hardware Installation The clock should be placed in a convenient location where employees typically enter and exit the work area. It includes a mounting plate with four holes. Mounting screws are included. Once the mounting plate is attached to the wall and all cables are connected, the clock’s face can be slid into place and secured to the mounting plate. 1.
Attach the clock mounting plate to the wall with the provided mounting screws.
2.
Connect the power cord to the bottom of the time clock and plug it into the closest electrical (110 - 120 VAC) outlet.
3.
Connect the RJ-11 connector of the cable (the one that looks like a phone-jack) into the right side port on the bottom center of the clock.
4.
Connect the 9-pin serial connector end of the communications cable to the “SERIAL” port.
5.
Insert a SIM card from your cellular phone company into the port labeled “SIM.”
6.
The clock can now be attached to the mounting plate. Place the top of the clock on the lip at the top of the mounting plate. Slide the clock over the center tab on the bottom of the clock until the center screw hole at the bottom of the clock aligns with the screw hole in the tab. Secure the clock by placing a screw through the aligned hole.
Velocity Clocks
Page 128
116
Qqest Software Systems, Inc.
Set Outbound Call Times This option allows you to specify how often stored punches are uploaded to the TimeForce database. 1.
From the clock keypad, press the <MENU> button and select 1 for “ADMIN.”
2.
Enter an administrator ID (or Card #) and press the <ENTER> key. Note: The default administrator ID is “8888.”
3.
Enter the password (or PIN) for the entered administrator ID and press the <ENTER> key. Note: The password for the default admin ID is “1111.”
4.
From the Main Admin Menu, press 3 for “Clock Setup.”
5.
Press 1 for “Communications.” The “CELLULAR MODEM” menu appears.
6.
Press 4 for “OUTBOUND OPTIONS.”
7.
Press 2 for “OUTBOUND CALL TIMES.”
8.
The “Outbound Call Times” menu opens. The following options are available: • • •
• •
Every Midnight: Select this option if you would like the clock to upload its stored punches every day at midnight. 9, 1 & 6:00: Select this option to have the clock upload its stored punches three times a day at 9 a.m., 1 p.m. and 6 p.m. Manual Only: With this option selected, the clock will not automatically upload its stored punches. The punches will remain in the clock until a manual upload is initiated. Note: See the section below for instructions on manually uploading your time clock. Real Time: With this option enabled, all punches entered at the clock will be immediately downloaded to the Clock Server. On Demand: When enabled, the clock will capture the employee’s card number at the clock and query the On Demand server to see if the employee exists in its database. If so, the employee will be allowed to continue with the punch procedure. When the punch process is complete, the resulting punch will be immediately transferred to the On Demand server.
Page 129
TimeForce II Hardware Guide
117
You can now exit the clock menu by pressing <CLR> repeatedly until you are brought back to the displayed time. Initiating a Manual Upload The stored data in the clock can be manually uploaded to the TimeForce database from the clock main menu. 1.
At the clock keypad, press the <MENU> button.
2.
Press 5 for “UPLOAD DATA.”
The clock initiates communication and uploads its stored data.
Uploading the Date and Time The date and time can be uploaded to the clock from the ClockLink utility. Before you will be able to upload the date and time, you must first create a time clock profile in TimeForce for each clock that you would like to connect to. 1.
Open the ClockLink utility. From the Windows Start Menu go to Programs | TimeForce II and click on “ClockLink.”
2.
Each time clock that has been set up in the TimeForce software is listed in the left-hand section of the screen. Highlight the clock that you would like to upload the date and time to and click on the “Connect” link.
3.
Once communication has been established with your time clock, the right-hand section of the screen opens. From the row of tabs at the top of the screen, ensure that [PARAMETERS] is selected.
4.
From the Actions section of the screen, click on the The “Upload Date/Time” screen opens. • icon.
Enter the desired Date. By default this field is populated with the system date of the machine that ClockLink is installed on. Click on the down-arrow icon at the end of the field to select the date from a calendar. Select the Use System Time option to restore the system date/time.
Velocity Clocks
Page 130
118
Qqest Software Systems, Inc.
•
•
Enter the Time. By default this field is populated with the system time of the machine that ClockLink is installed on. Click on the up and down arrow keys at the end of the field to select the time, or place your cursor in the field and manually type the desired time. Select the Use System Time option to restore the system date/time. Click on the [OK] icon to send the date and time to the clock. You can now exit the ClockLink utility.
Note: The date and time can also be manually specified from the clock keypad. See “Set Date/Time” on page 149 for further instructions.
V800 Clock Usage Instructions The V800 is an advanced model of clock with many options and features. It can be used to restrict employee punching, requiring a supervisor override for unassigned employees. This model also allows your employees to view various information at the clock itself such as accrual totals and the date and time of their last clock entry.
Creating a Clock Profile The time clock allows employees to access their current punch, schedule, accrual, and departmental information directly from the clock. This information is sent to the time clock using the ClockLink utility. A time clock profile must be created in TimeForce for each time clock. 1.
Open the TimeForce software and log in as a user with administrative rights.
2.
Click on the main “Clocks” navigation tab at the top of the screen.
3.
From the New Clocks section, click on the [ADD CLOCK] icon.
4.
Select “V800” from the Model drop-down menu.
5.
Enter the clock Number. This number is assigned in the memory of the time clock itself. The default number is “1.”
6.
Enter the clock Password. This is the password that is assigned at the time clock itself. The default clock password is “V800.”
Page 131
TimeForce II Hardware Guide
119
Note: See “How Do I Find the V800 / V850 Clock ID and Password?” on page 105 for further instructions. 7.
Enter a Description for this clock as you would like it to appear in TimeForce II and ClockLink.
8.
If you would like to assign this clock to a group, make the desired selection from the Group Name drop-down menu. Note: See page 211 for instructions on creating clock groups.
9.
If you would like to assign the clock to a Default Department level, click on the “No Department” link, and make the desired selection from the tree-directory that appears.
10. The Vacation Time drop-down menu contains each accrual policy that you have inserted into the TimeForce system. Select the policy that employee vacation time is deducted from. This setting allows your employees to log into the time clock and view their available vacation hours. 11. The Sick Time drop-down menu contains each accrual policy that you have inserted into the TimeForce system. Select the policy that employee sick time is deducted from. This setting allows your employees to log into the time clock and view their available sick time hours. 12. If you would like to upload relay events to the time clock, put a check mark in the Upload Relay Events field. See “Relay Events” on page 132 for more information. 13. Select the Time Zone that the clock will reside in from the dropdown menu. 14. Enter any desired Notes about this time clock in the provided textentry field. 15. Select the Connection Type from the drop-down menu. The steps to completing the clock profile vary slightly depending on what connection type you are using. •
Ethernet: Put a check mark in the DHCP option to use Dynamic Host Configuration Protocol. Otherwise, enter the IP Address where the clock can be reached. Remember to use periods. If the clock can only be reached using a specific port number, enter the appropriate port into the Port Number field. Leave this field blank to use the default port.
Velocity Clocks
Page 132
120
Qqest Software Systems, Inc.
•
•
•
Note: These settings are specific to your network setup. Qqest Software Systems cannot supply these settings. Serial: Select the Com Port that the clock is connected to from the drop-down menu. Select “Auto Detect” to have the system automatically determine which port the clock is connected to. Modem: In the Phone Number field, enter the phone number of the line that the clock is connected to. Enter the number exactly as you would dial it into a telephone, including any necessary area code or extension numbers. Do not use dashes or brackets. Example: A phone number of (800) 555-4855 would be entered as “18005554855.” Cellular: Put a check mark in the DHCP option to use Dynamic Host Configuration Protocol. Otherwise, enter the IP Address where the clock can be reached. Remember to use periods. If the clock can only be reached using a specific port number, enter the appropriate port into the Port Number field. Leave this field blank to use the default port. Note: These settings are specific to your network setup. Qqest Software Systems cannot supply these settings.
Before you can customize the information to be sent to the clock from TimeForce II, you must first add the clock profile to the system. Click on the [CREATE] icon located in the lower left-hand section of the screen.
Customizing Time Clock Information Multiple levels of information can be sent to the time clock from the TimeForce II database. Relay Events Qqest time clocks come with an optional feature called “Relay Events.” This feature allows you to connect an external bell, buzzer or other signal device to the time clock and program specific times of the day for the signal to go off, usually indicating schedule start, stop or break times. Each time clock can handle up to 32 relay events.
Page 133
TimeForce II Hardware Guide
121
Relay Events are assigned to time clock profiles in TimeForce II. Use the following instructions to assign relay events to your time clock profiles. Note: The option to edit Relay Events will only appear if the “Upload Relay Events” option is selected in the time clock profile. 1.
Open the TimeForce II software and log in as an administratorlevel user.
2.
Click on the main “Clocks” navigation tab at the top of the screen.
3.
From the Existing Clocks section of the screen, click on the [EDIT/ VIEW] icon.
4.
The program allows you to search for existing clock profiles based on the clock group that they are assigned to. Make the desired selection from the Group drop-down menu. Select “All” to bring up all time clock profiles.
5.
Click on the [DISPLAY] icon. The found clock profiles are displayed.
6.
Locate the desired time clock, and click on the “View” link in the Relay Events column. Note: This link will only appear if the “Upload Relay Events” option is selected in the time clock profile.
7.
To create a new relay event, click on the [ADD] icon.
8.
In the Relay Time column, enter the time of day that this event is to be activated. The time must be entered in 24-hour format.
9.
In the Duration Seconds column, enter the number of seconds that you want the bell or buzzer to sound for when the event is activated.
10. When the relay event occurs, it can either pulse for its duration or it can sound continuously. With Pulse selected, the bell or buzzer sounds as a series of pulses (on...off...on...off...on...off) for the duration of the event. If not selected, the bell or buzzer sounds continuously for the duration of the event. 11. Put a check mark in the box for each day of the week on which you want this event to occur. 12. Click on the [ADD] icon to insert additional events. Click on the [SAVE] icon to save the changes that you have made.
Velocity Clocks
Page 134
122
Qqest Software Systems, Inc.
The clock can handle up to 32 relay events. To remove a relay event from the clock profile, click on the icon. Employees at Clock The time clock gives you the option of restricting the employees who are allowed to punch in and out. If an employee who is not assigned to this time clock attempts to punch they will receive an error stating that they are not assigned to the clock, and that a supervisor override is required. A supervisor can then enter their clock password and allow the punch, if desired. By default all employees are allowed to punch at the time clock. Use the following instructions to restrict employees. 1.
Open the TimeForce II software and log in as an administratorlevel user.
2.
Click on the main “Clocks” navigation tab at the top of the screen.
3.
From the Existing Clocks section of the screen, click on the [EDIT/ VIEW] icon.
4.
The program allows you to search for existing clock profiles based on the clock group that they are assigned to. Make the desired selection from the Group drop-down menu. Select “All” to bring up all time clock profiles.
5.
Click on the [DISPLAY] icon. The found clock profiles are displayed.
6.
Locate the desired clock profile in the list, and click on the link in the Number column. The clock profile opens. The Employees at the Clock setup is located in the bottom section of the screen.
7.
Remove the check mark from the Send All Employees option. The Departments, Supervisors and Other Employees sections appear. •
The Departments section allows you to restrict employees based on the default department level that they are assigned to. All department levels appear in the “Unassigned” box. Highlight the departments that you would like to allow to use this clock, and click on the icon. The selected departments are moved to the “Assigned” box.
Page 135
TimeForce II Hardware Guide
•
•
•
123
The Supervisors section allows you to restrict employees based on the supervisor that they are assigned to in the system. All supervisors appear in the “Unassigned” box. Highlight the supervisors that you would like to allow to use this clock, and click on the icon. The selected supervisors are moved to the “Assigned” box. The Other Employees option allows you to assign or restrict employees on an individual basis. The settings in this section override any assignments made in the “Departments” or “Supervisor” sections. Your employees are displayed in the All Employees box. Highlight the desired employees, and click on the icon to assign them to the clock. Click on the icon to restrict them from the clock. The Current Assigned Employees section to the right displays all employees assigned to the clock, based on all 3 selection methods.
To unassign employees from any section, highlight the desired settings in the Assigned box and click on the icon. The selections are moved to the Unassigned box. Click on the [UPDATE] icon located at the bottom of the screen to save the changes that you have made.
Editing and Deleting Existing Clock Profiles Time clock profiles are displayed in the “Clock Settings” section of the TimeForce program. 1.
Open the TimeForce II program and log in as an administrator-level user.
2.
Click on the main “Clocks” navigation tab at the top of the screen.
3.
From the Existing Clocks section of the screen, click on the [EDIT/ VIEW] icon.
4.
If you would like to view clock profiles belonging to a specific clock group only, make the desired selection from the Group Name drop-down menu. Select “All” to display all time clock profiles.
Velocity Clocks
Page 136
124
Qqest Software Systems, Inc.
5.
The Sort by fields allow you to select how the displayed list of clock profiles are sorted.
6.
Click on the [DISPLAY] icon to view time clock profiles.
7.
Clock profiles are displayed under the Clock List section of the screen. The following information is displayed for each profile. •
• • •
• • •
•
Number: This is the ID of the displayed time clock. The setting in this field is a link. Click on the link to bring up the profile for this clock. Model: This column displays the clock model (as in “IQ400,” “IQ1000,” etc.). Connection Type: This is the type of connection that the time clock uses (as in “Serial,” “Ethernet,” “Modem,” etc.). Method: This is the additional information entered, based on the connection type (as in the com port selected, or the phone number entered, etc.). Group: If the time clock is assigned to a clock group, this field displays the name of the group that the clock is assigned to. Description: This is the description that was inserted when the clock profile was created. Relay Events: If you selected the “Upload Relay Events” option when creating the clock profile, a “View” link appears in this field. Click on the link to manage Relay Events for the clock. Click on the icon to remove a clock profile from the system.
Enrolling Finger ID Templates Before your employees will be able to enter punches at the V800, their finger IDs must first be enrolled at the clock. 1.
Press the <MENU> button on the time clock keypad. Select 1 for “Admin.” The following message appears: ENTER YOUR CARD #
2.
Enter the card number of a user that has access to the “Admin” clock features and press the <ENTER> key on the clock keypad. Note: The default administrator username is “8888.” The following message appears: