Page 137
TimeForce II Hardware Guide
125
ENTER PIN: 3.
Enter the password for the given card number and press the <ENTER> key on the clock keypad. Note: The default administrator password is “1111.”
4.
The main menu appears with several options. Press 2 for “Manage Finger IDs.”
5.
Press 1 for “New Finger ID.”
6.
The prompt ENTER CARD NUMBER appears. Enter the card number or keypad entry number that you assigned to this employee in the TimeForce software and press <ENTER>.
7.
A prompt appears that reads: CARD # XXXX:YY FIRST OF 2 SCANS PUT FINGER ON SENSOR
8.
9.
Note: “XXXX” denotes the employee’s card number. “YY” denotes the number of templates already stored in the clock for the displayed card number. Have the employee whom you are enrolling place his or her finger in the template reader. Usually the index finger is used, though the middle and ring fingers can also produce good results. To ensure correct placement, the employee should place the first joint of the finger against the raised ridge at the base of the reader screen, and place the fingertip firmly against the screen. Once the clock has read the finger, the following message appears: QUALITY: [X]/100 OK TO ACCEPT? YES NO This message denotes the general quality of the template read. You want the “QUALITY” to be as high as possible. Press the soft key under “YES” to accept the template read. Press the button below “NO” to have the clock read the template again.
Velocity Clocks
Page 138
126
Qqest Software Systems, Inc.
10. If the “QUALITY” read is too low, the following message may appear: QUALITY: [X]/100 QUALITY LOW RETRY ACCEPT If you get this message, you can have the employee moisten his or her finger slightly. Moisture helps the reader collect a high quality reading of the finger.
Deleting Existing Finger ID Records To delete a finger ID record, from the “Manage Finger IDs” menu select 2 for “Delete.” The clock asks you to enter the card number of the employee whose templates are to be deleted. Type in the card number and press <ENTER>. The following message appears: PLEASE CONFIRM - OK TO DELETE TEMPLATES FOR CARD [X]? YES NO Press the soft key under the “YES” option to delete this employee’s stored finger ID templates.
Setting the Global Security Level Use the following instructions to change the global security level. 1.
Press the <MENU> button on the keypad, select the “Admin” menu option, and enter your card number and password.
2.
Press 2 for “Manage Finger IDs.”
3.
Press 4 for “Global Security.” The following message appears: GLOBAL SECURITY NOW: 3 0=AUTO, 1=MIN, 5=MAX NEW SECURITY:
The default global security level is 3. Type in the new security level and press the <ENTER> key.
Page 139
TimeForce II Hardware Guide
127
Collecting Data Punching in and out is very simple with the V800. Within the TimeForce software, each employee is assigned a “Card Number.” This number corresponds with the number assigned to the employee’s finger templates stored in the time clock itself. If the V800 is ready to accept punches, the word “Ready” appears in the display panel with the date and time.
Time & Attendance Punches Use the following instructions to enter basic time and attendance punches at the clock (with no job, task or department information). 1.
Check to see that the clock display reads “Ready” with the date and time displayed at the top of the screen.
2.
Enter your card number at the clock keypad and press <ENTER>. The display panel shows the card number and reads: CARD #[X] READING FINGER ID PUT FINGER ON SENSOR
3.
Place your finger on the template reader. To ensure correct placement, the finger should be placed with the first joint of the finger against the raised ridge at the base of the reader screen, and with the fingertip pressed firmly against the screen. Once your finger ID has been verified, the following message is displayed: ID [X] CHOOSE IN/OUT ENTER = ACCEPT
4.
Press the <ENTER> key to complete the time & attendance entry. Note: The <ENTER> key should always be pressed when completing a punch at the time clock, unless the “Quick Punch” system option is enabled. See “Quick Punch” on page 157.
Velocity Clocks
Page 140
128
Qqest Software Systems, Inc.
Other Punch Options After the ID number has been specified, press <ENTER> to enter the punch and have the software determine whether it is an in or out punch. If you wish to assign the punch a type, press the <IN>, <MEAL>, <BREAK>, or <OUT> buttons, then press <ENTER>. You can press the buttons in combination to specify a punch type; for example, <MEAL> plus <OUT>, or <BREAK> plus <IN>. If you make a mistake, such as accidentally pressing <IN> rather than <OUT>, simply press the correct button and the display shows the new punch type you’ve specified. When the punch type is correct, press <ENTER>. Unless you have enabled the clock’s Quick Punch feature, you should always press <ENTER> to complete a punch entry at the V800. Note: The <MEAL> and <BREAK> keys on the clock keypad can be enabled and disabled from the clock menu. See “Keypad Behavior” on page 154 for more information.
V850 Clock Usage Instructions V850 is our most advanced model of clock with many options and features. It can be used to restrict employee punching, allowing employees to punch at the clock during their scheduled shift times only. This model also allows you to track Jobs, Tasks, Departments, and Tips at the clock. Employees can also view various information at the clock itself such as accrual totals, scheduled shift times and the date and time of their last clock entry.
Creating a Clock Profile The time clock allows employees to access their current punch, schedule, accrual, and departmental information directly from the clock. This information is uploaded to the time clock using the ClockLink utility. A time clock profile must be created in TimeForce II for each time clock. 1.
Open the TimeForce software and log in as a user with administrative rights.
2.
Click on the main “Clocks” navigation tab at the top of the screen.
3.
From the New Clocks section, click on the [ADD CLOCK] icon.
Page 141
TimeForce II Hardware Guide
129
4.
Select “V850” from the Model drop-down menu.
5.
Enter the clock Number. This number is assigned in the memory of the time clock itself. The default number is “1.”
6.
Enter the clock Password. This is the password that is assigned at the time clock itself. The default clock password is “V850.” Note: See “How Do I Find the V800 / V850 Clock ID and Password?” on page 105 for further instructions.
7.
Enter a Description for this clock as you would like it to appear in TimeForce II and ClockLink.
8.
If you would like to assign this clock to a group, make the desired selection from the Group Name drop-down menu. Note: See page 211 for instructions on creating clock groups.
9.
If you would like to assign the clock to a Default Department level, click on the “No Department” link, and make the desired selection from the tree-directory that appears.
10. The Vacation Time drop-down menu contains each accrual policy that you have inserted into the TimeForce system. Select the policy that employee vacation time is deducted from. This setting allows your employees to log into the time clock and view their available vacation hours. 11. The Sick Time drop-down menu contains each accrual policy that you have inserted into the TimeForce system. Select the policy that employee sick time is deducted from. This setting allows your employees to log into the time clock and view their available sick time hours. 12. If you would like to upload individual employee schedules to the time clock, put a check mark in the Upload Schedules field. This setting makes it so that employees can only punch at the time clock during the range of time specified in the schedule that they are assigned to. Note: In order for this feature to function properly, employees must be assigned to a schedule in the TimeForce system. Also, employee schedules must be assigned to a Schedule Template. 13. If you would like to upload relay events to the time clock, put a check mark in the Upload Relay Events field. See “Relay Events” on page 132 for more information.
Velocity Clocks
Page 142
130
Qqest Software Systems, Inc.
14. Select the Time Zone that the clock will reside in from the dropdown menu. 15. Enter any desired Notes about this time clock in the provided textentry field. 16. Select the Connection Type from the drop-down menu. The steps to completing the clock profile vary slightly depending on what connection type you are using. •
•
•
•
Ethernet: Put a check mark in the DHCP option to use Dynamic Host Configuration Protocol. Otherwise, enter the IP Address where the clock can be reached. Remember to use periods. If the clock can only be reached using a specific port number, enter the appropriate port into the Port Number field. Leave this field blank to use the default port. Note: These settings are specific to your network setup. Qqest Software Systems cannot supply these settings. Serial: Select the Com Port that the clock is connected to from the drop-down menu. Select “Auto Detect” to have the system automatically determine which port the clock is connected to. Modem: In the Phone Number field, enter the phone number of the line that the clock is connected to. Enter the number exactly as you would dial it into a telephone, including any necessary area code or extension numbers. Do not use dashes or brackets. Example: A phone number of (800) 555-4855 would be entered as “18005554855.” Cellular: Put a check mark in the DHCP option to use Dynamic Host Configuration Protocol. Otherwise, enter the IP Address where the clock can be reached. Remember to use periods. If the clock can only be reached using a specific port number, enter the appropriate port into the Port Number field. Leave this field blank to use the default port. Note: These settings are specific to your network setup. Qqest Software Systems cannot supply these settings.
17. Before you can customize the information to be sent to the clock from TimeForce II, you must first add the clock profile to the system. Click on the [CREATE] icon located in the lower left-hand section of the screen.
Page 143
TimeForce II Hardware Guide
131
Customizing Time Clock Information Multiple levels of information can be uploaded to the time clock from the TimeForce database. Allowed Period This is the period of time during which the time clock will accept punches. Any employee punching outside of this time range will receive an error message stating that supervisor approval is required in order to complete this punch. The punch will only be recorded if a supervisor user enters their administrator password and “clears” the punch. Note: Default Allowed Periods are only used when employee schedules are not uploaded to the clock. When schedules are being used, the time range specified in the Schedule Template that the employee's schedule is assigned to is used as the employee's allowed period. Default Allowed Periods are specified within each clock's time clock profile in the TimeForce II system. Use the following instructions to customize allowed periods. 1.
Open the TimeForce II software and log in as an administratorlevel user.
2.
Click on the main “Clocks” navigation tab at the top of the screen.
3.
From the Existing Clocks section of the screen, click on the [EDIT/ VIEW] icon.
4.
The program allows you to search for existing clock profiles based on the clock group that they are assigned to. Make the desired selection from the Group drop-down menu. Select “All” to bring up all time clock profiles.
5.
Click on the [DISPLAY] icon. The found clock profiles are displayed.
6.
In the Number column, click on the ID of the time clock that you would like to specify allowed periods for. The “Clock” screen appears. The Allowed Periods setup is located directly below the clock info section of the screen.
Velocity Clocks
Page 144
132
Qqest Software Systems, Inc.
7.
For each day of the week, enter the start time and end time of the range during which employees are allowed to punch at the clock. To leave a day unrestricted, set the start time to “00:00” and the end time to “23:59.”
8.
Click on the [UPDATE] icon located at the bottom of the screen to save the changes that you have made to the time clock profile.
Relay Events Qqest time clocks come with an optional feature called “Relay Events.” This feature allows you to connect an external bell, buzzer or other signal device to the time clock and program specific times of the day for the signal to go off, usually indicating schedule start, stop or break times. Each time clock can handle up to 32 relay events. Relay Events are assigned to time clock profiles in TimeForce II. Use the following instructions to assign relay events to your time clock profiles. Note: The option to edit Relay Events will only appear if the “Upload Relay Events” option is selected in the time clock profile. 1.
Open the TimeForce II software and log in as an administratorlevel user.
2.
Click on the main “Clocks” navigation tab at the top of the screen.
3.
From the Existing Clocks section of the screen, click on the [EDIT/ VIEW] icon.
4.
The program allows you to search for existing clock profiles based on the clock group that they are assigned to. Make the desired selection from the Group drop-down menu. Select “All” to bring up all time clock profiles.
5.
Click on the [DISPLAY] icon. The found clock profiles are displayed.
6.
Locate the desired time clock, and click on the “View” link in the Relay Events column. Note: This link will only appear if the “Upload Relay Events” option is selected in the time clock profile.
7.
To create a new relay event, click on the [ADD] icon.
8.
In the Relay Time column, enter the time of day that this event is to be activated. The time must be entered in 24-hour format.
Page 145
TimeForce II Hardware Guide
9.
133
In the Duration Seconds column, enter the number of seconds that you want the bell or buzzer to sound for when the event is activated.
10. When the relay event occurs, it can either pulse for its duration or it can sound continuously. With Pulse selected, the bell or buzzer sounds as a series of pulses (on...off...on...off...on...off) for the duration of the event. If not selected, the bell or buzzer sounds continuously for the duration of the event. 11. Put a check mark in the box for each day of the week on which you want this event to occur. 12. Click on the [ADD] icon to insert additional events. Click on the [SAVE] icon to save the changes that you have made. The clock can handle up to 32 relay events. To remove a relay event from the clock profile, click on the icon. Employees at Clock The time clock gives you the option of restricting the employees who are allowed to punch in and out. If an employee who is not assigned to this time clock attempts to punch they will receive an error stating that they are not assigned to the clock, and that a supervisor override is required. A supervisor can then enter their clock password and allow the punch, if desired. By default all employees are allowed to punch at the time clock. Use the following instructions to restrict employees. 1.
Open the TimeForce II software and log in as an administratorlevel user.
2.
Click on the main “Clocks” navigation tab at the top of the screen.
3.
From the Existing Clocks section of the screen, click on the [EDIT/ VIEW] icon.
4.
The program allows you to search for existing clock profiles based on the clock group that they are assigned to. Make the desired selection from the Group drop-down menu. Select “All” to bring up all time clock profiles.
5.
Click on the [DISPLAY] icon. The found clock profiles are displayed.
Velocity Clocks
Page 146
134
Qqest Software Systems, Inc.
6.
Locate the desired clock profile in the list, and click on the link in the Number column. The clock profile opens. The Employees at the Clock setup is located in the bottom section of the screen.
7.
Remove the check mark from the Send All Employees option. The Departments, Supervisors and Other Employees sections appear. •
•
•
•
8.
The Departments section allows you to restrict employees based on the default department level that they are assigned to. All department levels appear in the “Unassigned” box. Highlight the departments that you would like to allow to use this clock, and click on the icon. The selected departments are moved to the “Assigned” box. The Supervisors section allows you to restrict employees based on the supervisor that they are assigned to in the system. All supervisors appear in the “Unassigned” box. Highlight the supervisors that you would like to allow to use this clock, and click on the icon. The selected supervisors are moved to the “Assigned” box. The Other Employees option allows you to assign or restrict employees on an individual basis. The settings in this section override any assignments made in the “Departments” or “Supervisor” sections. Your employees are displayed in the All Employees box. Highlight the desired employees, and click on the icon to assign them to the clock. Click on the icon to restrict them from the clock. The Current Assigned Employees section to the right displays all employees assigned to the clock, based on all 3 selection methods.
To unassign employees from any section, highlight the desired settings in the Assigned box and click on the icon. The selections are moved to the Unassigned box. Click on the [UPDATE] icon located at the bottom of the screen to save the changes that you have made.