Page 219
TimeForce II Hardware Guide
207
Cable Specifications Serial Clocks In order to ensure proper clock operation, the cable between the computer and the clock and the cable between clocks must meet certain specifications, and also must be correctly pinned out to the computer’s serial port. • • •
• • •
•
The cable between the computer and the Master Serial time clock must not exceed 200 feet in length. The total length of the cable from the Master to the last Daisy clock must not exceed 4000 feet in length. Any cable over 20 feet in length should be shielded, and should not have any splices. It is recommended that you use shielded cable supplied by Qqest. If you are unable to use cable supplied by Qqest, category 3 or 5 Shielded Twisted Pair cable may be used, but you should only use 1 wire from each twisted pair, and abandon the other wire of each pair. For example, you could use the blue, brown and orange solid-colored wires, and leave the blue/white, brown/ white and orange/white wires unconnected on each end. Performance will be reduced (you may not be able to achieve reliable daisy communications all the way to 4000 feet), but for shorter distances performance should be adequate. The PC Connector is a standard DB-9 female serial connector. The Connector to the Master port labeled “Phone/Computer/Daisy” must be RJ-12 (6 Pin). The connector from the Master to Daisy or Daisy to Daisy can be either an RJ-11 or RJ-12, but only 4 contacts are required. The cable must only contain 4 wires (not 6). If you have a 25-pin serial port you can either use a DB25 to DB9 serial adapter (recommended), or build your own cable using a DB25 connector. Contact Qqest Technical Support for a pinout diagram.
Cable Specifications
Page 220
208
Qqest Software Systems, Inc.
•
The physical path of the cable must be as free as possible of electromagnetic interference (EMI) or radio frequency interference (RFI). Shielded cable will decrease vulnerability to such interference, but cannot guarantee its elimination. Avoid running cable over or near florescent lighting, electric motors, power distribution panels, transmitters or UTP network cable bundles. Try to keep the cable length as short as possible. Data transmission problems may occur if the cable is exposed to any such interference: loss of data, duplicate punch data, packet errors and corruption.
Cable Pinouts Connect pin 2 on the DB9 to pin 1 on the RJ12. Then connect pin 3 on the DB9 to pin 6 on the RJ12. Then connect pin 5 on the DB9 to pin 3 on the RJ12. Jumper pins 4 and 6 on the DB9 together and pins 1, 7 and 8 on the DB9 together. See Figures HARDWARE-10 and 11 below.
Page 221
TimeForce II Hardware Guide
209
Figure HARDWARE-11: Cable Pinouts
Figure HARDWARE-12: Cable Pinouts
Cable Specifications
Page 222
210
Qqest Software Systems, Inc.
Modem Clocks Due to possible problems when running a modem clock on some types of phone systems, we require that only a “two wire” phone cable be used with our clocks (as opposed to the standard “four wire” cable). This prevents possible damage to the clock motherboard or modem due to power running through the extra two wires. We have provided a two wire phone cable with the clock. If you need longer cables, please use this cable as a template to properly modify a standard four wire phone cable, or you can purchase a new cable of sufficient length from Qqest Software Systems. If you have any questions, please call our Technical Support department at (800)697-7010.
Ethernet Clocks The Ethernet clock uses a standard Category 5 (CAT5) shielded network cable. The clock comes with a 20 ft. cable. If a longer length is needed, any standard CAT5 cable will work.