How Do I Create Clock Groups? The TimeForce system allows you to organize your time clocks by assigning them to clock groups. Groups can be created based on their location, the employees that will be using the clock, etc. Clock groups are created from the “Clocks” section of the TimeForce program.Open the TimeForce program and log in as an administratorlevel user. 1.
Click on the main “Clocks” navigation tab located at the top of the screen.
2.
From the New Clocks section of the screen, click on [ADD GROUP].
3.
To create a new clock group, click on the [ADD] icon located to the right of the Name header.
4.
Enter a Name for this clock group.
5.
Click on the [CREATE] icon to add the group.
6.
Enter as many groups as desired. To remove a group, click on the icon located to the right of each displayed group.
The Clock Group drop-down menu in the “Clock Settings” section of the program will now have options to choose from.
How Do I Create Clock Groups?
Page 224
212
Qqest Software Systems, Inc.
Page 225
TimeForce II Hardware Guide
213
Finger ID Sensor Cleaning Instructions The following instructions walk you through cleaning the finger ID sensor on your IQ 1000, V800 or V850 time clock. Although maintenance and handling requirements for the sensor are few in number, observance of a few basics will help to ensure a high level of performance over the life of the sensor.
Cleaning the Finger ID Sensor Oily deposits from your finger accumulate on the surface of the template sensor after repeated use. These deposits can inhibit the functionality of the sensor. It is recommended that the sensor be cleaned at least once per week, but it should also be cleaned anytime an oily residue is visible on the sensor surface. Use rubbing alcohol and a clean cotton cloth or tissue paper to remove oily deposits. Do not use a soiled cloth or tissue paper to clean the sensor. A clean cotton cloth or tissue paper will absorb the deposits, but a soiled cloth will smear deposits over the sensor surface. Rubbing alcohol is the preferred cleaning solution because it absorbs the oily residue and evaporates quickly. The use of nylon brushes or scouring pads, abrasive cleaning fluids or powders, or steel wool is not recommended.
Finger ID Sensor Cleaning Instructions
Page 226
214
Qqest Software Systems, Inc.
Caring for the Finger ID Sensor The sensor is designed to perform well even under harsh conditions. Nevertheless, some precautions should be taken to avoid damage. •
•
• •
The sensor can be damaged by a discharge of static electricity from your body. However, the ridge at the base of the sensor is made with conductive plastic designed to discharge any static from your skin or clothing before your finger comes in contact with the sensor itself. It is recommended that you use a static discharge plate which is connected to a ground plane (contact Qqest Accessory Sales for more information). You should always discharge the static electricity from your body before touching the fingerprint sensor. Do not place the clock close to a heat source, such as a radiator or hot plate. The sensor should also be protected from excessive moisture or liquids. Do not subject the sensor to heavy shocks or vibrations. Do not allow the sensor to come into contact with metallic objects.