The text of a manual · part 21 of 30
Time Force II Hardware Guide: Velocity Clocks, pages 167 to 174
Pages 167 to 174 of 234, from Time Force II Hardware Guide
The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Qqest V800
Page 167
TimeForce II Hardware Guide
155
Job Key This option enables the <JOB>, <TASK> and <QTY> keys on model V850 clocks. These keys are used to add Job Tracking information to employee punches. Department Key This option enables the <DEPT> key on the V850 clock keypad. Tips Key This option enables the <TIPS> key on the V850 clock keypad.
Finger ID Devices This menu allows you to configure the finger ID reader on your clock, and contains the following options: 1. SHOW SETTINGS 2. ENABLE READER 3. REQ’D FOR MENUS Show Settings This option displays the settings that your finger ID device is currently set to. Enable Reader This option allows you to turn finger template verification on or off for all employees. With this option disabled, no employees will be asked to place their finger on the sensor when clocking in or out. When this option is selected, the following prompt appears: FINGER ID ENABLED? NOW: YES *ENTER* WHEN DONE YES NO Press the soft key under the “YES” or “NO” option, as desired. Required for Menus With this option enabled, finger template verification is required in order to access the clock’s menu options. When this option is selected, the following prompt appears:
Velocity Clocks
Page 168
156
Qqest Software Systems, Inc.
REQUIRE FP FOR ADMIN NOW: NO *ENTER* WHEN DONE YES NO Press the soft key under the “YES” or “NO” option, as desired.
External Devices Use this menu option to specify how your clock is to work with an external device (such as a bell/buzzer). The following options are available: 1. DISABLE RELAYS 2. ENABLE BREAK BELL 3. ENABLE DOOR CTRL Disable Relays This option allows you to disable the current relay setup. No external device attached to the clock relay will operate with this option selected. Enable Break Bell This option enables a bell relay connected to the clock and disables any door security relay that may be attached. Note: A bell relay may be an external bell, buzzer or other signal device. Enable Door Control This option enables a door security relay setup that is attached to the clock, and disables all bell relay setups. Select this option when you would like to use the clock’s relay in conjunction with an external door locking mechanism, making it so that employees can gain access to a secured area upon successful verification of their finger ID.
Display Options This menu allows you to configure how your clock display and keypad functions, and contains the following options: 1. US/EURO DATE 2. QUICK PUNCH 3. GLOBAL TIMEOUT 4. LCD BACKLIGHT
Page 169
TimeForce II Hardware Guide
157
US/Euro Date This option allows you to select whether you would like the date shown on the face of your clock to be displayed in US or European format. Note: US date format is “MM/DD/YYYY.” European date format is “DD/MM/YYYY.” Quick Punch With this feature enabled, employees do not have to press the final <ENTER> when clocking in or out. Global Timeout This option allows you to specify the amount of time in seconds after which the clock will “timeout” to the Ready screen due to inactivity. The default setting is 30 seconds. LCD Backlight This option allows you to enable “Power Save” mode on the clock. With this option enabled, the backlight on the clock will only be lit when the clock is in use.
Punch Restrictions Use this option to restrict the information that your employees are able to specify with their punches. This menu has several options: 1. LUNCH RESTRICT 2. SUPERVISOR OVERRIDE 3. EMPL NOT IN CLOCK 4. RESTRICT JOBS 5. RESTRICT TASKS 6. RESTRICT DEPT. Lunch Restriction Enabling this option requires the employee to take a lunch break during their shift. The length of the lunch is configured on a per-employee basis in TimeForce. This data is then sent to the clock and enforced when this option is enabled. Supervisor Override This option causes the “Supervisor Required” message to not be displayed at the clock on schedule violations (for employees not in the clock, use the “Use Default Schedule” option). Velocity Clocks
Page 170
158
Qqest Software Systems, Inc.
Employee Not in Clock This option allows you to specify whether an employee who is not in the time clock uses the default schedules stored in the clock memory, or requires a supervisor override in order to punch. Restrict Jobs When enabled, the clock will only accept job numbers that have been sent to the clock from the TimeForce system. All other job numbers will be denied, and the punch attempt will be rejected. Restrict Tasks When enabled, the clock will only accept task numbers that have been sent to the clock from the TimeForce system. All other task numbers will be denied, and the punch attempt will be rejected. Restrict Departments When enabled, the clock will only accept department numbers that have been sent to the clock from the TimeForce system. All other department numbers will be denied, and the punch attempt will be rejected.
Personal Clock Interface The “Personal” menu options allow your employees to log into the clock and view various kinds of information. This menu contains the following options: 1. VALID PUNCH TIMES 2. ACCRUALS 3. DEPT, PERS. 4. FIND PUNCHES
Valid Punch Times Select this option to view the window of time during which you are allowed to punch at the time clock. This option is used when the administrator has uploaded schedules to the clock from the TimeForce database.
Page 171
TimeForce II Hardware Guide
159
Accruals Select this option to view the number of “Sick” and “Vacation” hours that you currently have available. Note: This option is updated each time an upload from the TimeForce database is performed. The displayed hours totals will only be as current as the last upload.
Department and Personal This menu option displays your default department level. Any “Employee Messages” are also displayed on this screen.
Find Punches This option allows you to view your punches that are currently being stored in the time clock’s memory. Use the “Scroll dn,” <IN>, and “Scroll up,” <OUT> keys to scroll through punches. Note: All punches that are currently stored in the memory of the time clock itself can be displayed. This includes punches that have been sent to the TimeForce database.
V800 / V850 On Demand Ethernet Clock The On Demand Ethernet Clock uploads any stored data to the Clock Server automatically. This makes the process of manually connecting to your time clock for the purpose of downloading its stored punches unnecessary. The clock can automatically upload any stored data to the Clock Server immediately upon its entry into the clock. Manual data upload can also be selected. Note: The following setup instructions are specific to the On Demand options. All other Ethernet setup steps are identical to the V800 / V850 Ethernet clock. See page 107 for further instructions.
Velocity Clocks
Page 172
160
Qqest Software Systems, Inc.
Setting the Push Server IP The time clock uploads its punch data to the Clock Server software. Before your clock will be able to successfully transfer punches, you must first enter the Push Server ID. Note: See page 5 for instructions on setting up the Clock Server. You may have chosen to use a Clock Server hosted by Qqest. In this case, the server IP should have been supplied to you at the time of purchase. 1.
From the keypad of the clock, press the <MENU> button and enter your password.
2.
Select 1 for “ADMIN.”
3.
Select 3 for “CLOCK SETUP.”
4.
Select 1 for “COMMUNICATION.”
5.
Select 4 for “OUTBOUND OPTIONS.”
6.
Select 3 for “PUSH SERVER IP.”
7.
From the keypad of the clock, enter the IP address of the Push Server. Remember to use the period [ . ] key. Once the IP has been entered, press <ENTER>. The “Port” screen appears.
8.
If a specific port number is required, enter it at the clock keypad. Press the upper-right soft key to automatically populate this setting with the default of “5402.” Note: In most cases, the default setting will be used.
9.
Press the <ENTER> key to save the changes that you have made. You can now exit the clock menu.
Set Dial Times The time clock allows you to specify how stored punches are uploaded to the database. 1.
From the keypad of the clock, press the <MENU> button and enter your password.
2.
Select 1 for “ADMIN.”
3.
Select 3 for “CLOCK SETUP.”
4.
Select 1 for “COMMUNICATION.”
5.
Select 4 for “OUTBOUND OPTIONS.”
Page 173
TimeForce II Hardware Guide
161
6.
Select 2 for “OUTBOUND CALL TIMES.”
7.
The “Outbound Call Times” screen opens. The following options are available: •
•
•
• •
Every Midnight: With this option selected, the clock will send all punches accumulated during the day to the Clock Server at 12:00 am. 9, 1, & 6:00: This option is intended to send punches when there are fewer employees actively punching at the clock. Punches will be sent at 9:00 am, 1:00 pm and 6:00 pm. Manual Only: With this option selected, the clock will not automatically send its stored punches. The punches will remain in the clock until a manual upload is initiated. Note: See the section below for instructions on manually uploading your time clock. Real Time: With this option enabled, all punches entered at the clock will be immediately uploaded to the Clock Server. On Demand: This option is only available with Ethernet and Cellular clocks. When enabled, the clock will capture the employee ID at the clock, and then query the On Demand server to see if this employee is in the database. If so, the employee will be allowed to continue the punch process. When the process is completed, the punch will be immediately transferred to the On Demand server.
You can now exit the clock menu by pressing <ENTER> repeatedly until you are brought back to the displayed time.
Initiating a Manual Upload The clock can be manually uploaded from the main “Main Menu.” 1.
Press the <MENU> button on the keypad.
2.
Select 4 for “Upload Data.” The clock initiates communication with the Clock Server and uploads its time and attendance data.
Note: You can also manually upload data by pressing the following combination of keys at the clock keypad: <MENU> < 9 > <ENTER>.
Velocity Clocks
Page 174
162
Qqest Software Systems, Inc.