Page 157
TimeForce II Hardware Guide
145
8.
If you are finished entering punch information, press the <ENTER> key to save the punch entry. If you would like to specify a quantity with the punch, press the <QTY> button. Note: The <QTY> button can be pressed at any point in the punch entry procedure (as long as the button is enabled from the clock System Options screen).
9.
Enter the desired quantity (remember to use the period key, if necessary), and press <ENTER> to save the punch.
Department Entries Use the following instructions to enter punches at the time clock that are assigned to a specific department level. There are two different types of department entries, “Department Overrides” and “Department Transfers.” 1.
Check to see that the clock display reads “Ready” with the date and time displayed at the top of the screen.
2.
Enter your card number at the clock keypad and press <ENTER>. The display panel shows the card number and reads: CARD #[X] READING FINGER ID PUT FINGER ON SENSOR
3.
Place your finger on the template reader. To ensure correct placement, the finger should be placed with the first joint of the finger against the raised ridge at the base of the reader screen, and with the fingertip pressed firmly against the screen. Once your finger ID has been verified, the following message is displayed: ID [X] CHOOSE: IN/OUT DEPT ENTER = ACCEPT
4.
Press the <DEPT> button on the clock keypad. The following is displayed:
Velocity Clocks
Page 158
146
Qqest Software Systems, Inc.
DEPT: PRESS IN OR OUT KEY TO SEL. FROM A LIST 5.
There are two different methods for selecting a department at the clock: •
•
6.
Department Number: Enter the number assigned to the department level in the TimeForce software, and press the <ENTER> button. Department List: Use the “Scroll dn” and “Scroll up” keys (also the <IN> and <OUT> keys) to scroll through the list of departments. When the desired department in the list is highlighted, press the <ENTER> button.
Note: The department list contains the department levels from the TimeForce program that have been uploaded to the time clock using the ClockLink utility. The clock prompts you to select whether you would like this punch to be a “TRANSFER” or an “OVERRIDE.” •
•
Department Transfer: This type of punch is used when an employee is already clocked into a department level, but needs to switch to a new department at some point during the day. Two entries are generated with each department transfer, an “out” punch from the current department, and an “in” punch for the new. Department Override: Employees can be assigned to a default department level in the TimeForce software. When employees punch at the time clock without entering department information, their punches are assigned to their specified default department. When an employee needs to clock in at the beginning of the day with a department number other than their default department level, a “department override” punch is used.
Select the desired option using the grey buttons located directly above the numeric keypad. You do not need to press the <ENTER> key. Once a selection has been made, the punch is automatically saved.
Page 159
TimeForce II Hardware Guide
147
Other Punch Options After the ID number has been specified, press <ENTER> to enter the punch and have the software determine whether it is an in or out punch. If you wish to assign the punch a type, press the <IN>, <MEAL>, <BREAK>, or <OUT> buttons, then press <ENTER>. You can press the buttons in combination to specify a punch type; for example, <MEAL> plus <OUT>, or <BREAK> plus <IN>. If you make a mistake, such as accidentally pressing <IN> rather than <OUT>, simply press the correct button and the display shows the new punch type you’ve specified. When the punch type is correct, press <ENTER>. Unless you have enabled the clock’s Quick Punch feature, you should always press <ENTER> to complete a punch entry at the V800. Note: The <MEAL> and <BREAK> keys on the clock keypad can be enabled and disabled from the clock menu. See “Keypad Behavior” on page 154 for more information.
Additional Clock Features A V800/V850 clock includes many advanced features. The following is a brief description of the features offered by this clock. Press the <MENU> button to see additional options. When you do so, a prompt appears asking you to enter your password. Type in your password and press <ENTER>. Note: When you purchase your clock, the default administrator password is set as “8888.” The default supervisor password is set as “1111.” Enter the default administrator password the first time that you use the clock. Once you have accessed the main menu, you can select the Passwords option and reset the defaults to the passwords of your choice.
Velocity Clocks
Page 160
148
Qqest Software Systems, Inc.
Main Menu When you enter your password, the Main Menu appears with the following options: 1. ADMIN 2. PERSONAL 3. RESTART CLOCK 4. PRODUCTION/TEST 5. UPLOAD DATA 6. GPRS SIG STRENGTH 7. REQUEST CONFIG 8. TST GPRS CONNECT Note: See “Personal Clock Interface” on page 158 for instructions on “Personal” clock options. • • •
•
•
The “Production/Test” option is for use by Qqest Software Systems, and is only accessible with a password. The “Upload Data” option will upload all of the current punches saved in the clock’s memory to the TimeForce system. The “GPRS Signal Strength” option is used by Cellular modem clocks only, and displays a bar graph showing the strength of the GPRS unit’s connection to the Cellular provider. The “Request Configuration” option is used by clocks configured for On Demand processing. This selection will ask the On Demand server to send all of the configuration settings that have been set up for use with the clock. The “Test GPRS Connection” option is used with Cellular modem clocks only, and will tell the clock to test the connections that hit has to the GPRS unit, and the connections to the Cellular network, and report the status of both.
Select 1 for “ADMIN.” The MAIN ADMIN MENU appears, with the following options: Note: Menus are displayed using vertical scrolling. Three options are visible at a time. Use the “Scroll dn” and “Scroll up” keys (also the <IN> and <OUT> keys) to view additional menu options.
Page 161
TimeForce II Hardware Guide
149
1. SET DATE/TIME 2. MANAGE FINGER IDS 3. CLOCK SETUP 4. REPORTS 5. MANAGE MEMORY 6. IB DENABD TESTS
Set Date/Time This option is used to manually set the date and time on your time clock. The date and time can also be uploaded from your computer’s system date and time using the ClockLink utility. When this option is selected, the SET DATE/TIME menu appears. SET DATE TIME 1. SET TIME 2. SET DATE Time To set the time on the clock, select the “Set Time” option by pressing the number 1 on the clock keypad, or by using the scroll keys to highlight the appropriate option and pressing the <ENTER> key. In 24-hour format, enter the appropriate time in the following format: “HH:MM:SS.” Press the <ENTER> key to save. Date To specify the date on the clock select the “DATE” option by either pressing the number 2 on the clock keypad, or by using the scroll keys to highlight the option and pressing the <ENTER> key. Using the clock keypad, enter the appropriate date in the following format: “MM/DD/ YYYY” and press the <ENTER> key.
Manage Finger IDs Select this option to manage your employees’ finger templates. Note: See clock usage instructions for detailed instructions on managing finger templates. The following options appear under this menu:
Velocity Clocks
Page 162
150
Qqest Software Systems, Inc.
1. NEW FINGER ID 2. DELETE 3. CHECK FOR ID 4. GLOBAL SECURITY New Finger ID Select this option to enroll an employee’s finger template. Delete This option allows you to delete the templates that are being stored by the time clock on an per-employee basis. Check For ID This option allows you to check an employee’s existing finger templates. Global Security By default the global security level for finger IDs is set to 3, the middle level of security. If you wish to, you may change the global security setting, though this is not recommended.
Clock Setup This menu allows you to customize how your time clock functions by configuring various system options. See page 153 for a detailed breakdown of this menu and its options.
Reports This option allows you to view reports about your clock hardware and firmware versions, as well as information about the data that is being stored by the clock. There are six options on this screen: 1. CLOCK INFORMATION 2. STORAGE USED 3. SYSTEM VERSION 4. COMPANY INFO 5. FINGER ID VERSION 6. DEFAULT SCHEDULES
Page 163
TimeForce II Hardware Guide
151
Clock Information This report shows the clock model, ID number, interface serial number, the GUID in ASCII format, and the product ID code. Storage Used This report allows you to view the amount of memory that is currently being used to store punches that have not been downloaded from the time clock. It displays the number of blocks used, and the number of packets currently stored. System Version This report allows you to view the clock’s boot and main code versions along with the date/time they were installed. It also displays the clock’s product code, and the revision number assigned to the motherboard. Company Information Use this report to view any company information that has been uploaded to your clock from the TimeForce system (such as, company name and company message). Finger ID Version Use this report to view model and version information on your clock’s finger ID reader. Default Schedules Use this information to view the default schedule information that has been uploaded to your clock from TimeForce.
Manage Memory This menu option gives you access to the memory of the time clock. From here, the following actions can be taken: 1. CLEAR PUNCH MEMORY 2. SET TO DEFAULTS 3. SCAN DATA MEM 4. CLEAR EMPLOYEE INFO 5. SEARCH FOR DATA 6. DUMP PUNCH MEM 7. TEST I2C MEMORY
Velocity Clocks
Page 164
152
Qqest Software Systems, Inc.
Clear Punch Memory When this option is selected, the clock will erase all punch data. Note: This procedure is irreversible. Any data that is cleared from the clock can never be recovered. Set to Defaults This option restores the clock to its default Clock ID and Password. Note: The ClockLink software uses the Clock ID and Password to communicate with your clock. The information specified in the Time Clock Profile must match the information set in the time clock itself. Scan Data Memory This option scans the memory set aside to hold employee punches. The number of punch packets currently saved in the clock is displayed along with the memory address of where punches start and end. It also looks for punch data being stored by the time clock looking for data that is outside of its known pointers. If data is found, the pointers are reset to include the found data, making the information available for download. This option is intended for use by Qqest Technical Support. Clear Employee Information This option clears all information that has been uploaded to the clock from the TimeForce system (such as employees, departments, default schedules, etc.). This option is not reversible. Once deleted, data must be re-uploaded to the clock using the ClockLink program. Search for Data This option scans the punch memory space and reports where punch data starts/ends in memory, and where the clock thinks it starts/ends. If the actual punch data differs from the information in the clock, the user is given the option to change the start/stop address to match the actual punch data locations. This option is intended for use by Qqest Technical Support.
Page 165
TimeForce II Hardware Guide
153
Dump Punch Memory This option lets the user view the actual punch data this is saved in the clock’s memory. Punches consist of 12 bytes of data, thus the first punch will be found at address 0, the second will be found at address 12. This address will increment to 24, 36, etc. Punch data is saved in hexadecimal and Binary Coded Decimal formats. Use the <IN> and <OUT> keys to move forward and backward through memory. Test I2C Memory This selection opens a menu that allows the user to test the different parcels of memory used in the clock. This option is intended for use by Qqest Technical Support.
Clock Setup This menu allows you to enable, disable and customize various time clock options. The main Clock Setup screen contains the following options: 1. COMMUNICATION 2. CLOCK ID/PASS 3. KEYPAD BEHAVIOR 4. FINGER ID DEVICES 5. EXTERNAL DEVICES 6. DISPLAY OPTIONS 7. PUNCH RESTRICTIONS
Communication The communications menu allows you to specify the settings that your clock uses to communicate. This screen varies depending on the communications type of your clock. See “Hardware Installation” on page 107 for detailed instructions on each clock type.
Clock ID/Pass This menu allows you to view and edit the ID and password that your clock uses to communicate. See “How Do I Find the V800 / V850 Clock ID and Password?” on page 105 for detailed instructions on this menu.
Velocity Clocks
Page 166
154
Qqest Software Systems, Inc.
Keypad Behavior This menu allows you to specify how the clock keypad functions, and contains the following options: 1. KEY CLICK 2. IN/OUT KEYS 3. MEAL/BREAK KEYS 4. KEY TONES 5. AUTO-ENTER ID 6. JOB KEY 7. DEPARTMENT KEY 8. TIPS KEY Key Click Enable this option if you want the clock to emit a short beep every time a key is pressed. In/Out Keys This option enables the <IN> and <OUT> keys on the clock keypad. Enable this option if you would like your employees to be able to specify an “in” or “out” status with their punches. Note: This option is not required. The TimeForce system automatically determines punch “in/out” order. Meal/Break Keys This option enables the <MEAL> and <BREAK> keys on the clock keypad. Enable this option if you would like to allow your employees to specify a punch as a “meal” or “break” punch. Key Tones This option allows you to enable or disable the tones that the clock emits when a punch is accepted. Note: It is not possible to disable punch error tones. Auto-Enter ID This option allows you to set the maximum number of digits for an ID. Example: The “Auto-Enter ID” setting is set to 3. As soon as the third digit in an ID is entered at the keypad, the punch is automatically entered (without pressing the <ENTER> key).