Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 30

Time Force II Hardware Guide: IntelliClock Setup Instructions

Pages 35 to 46 of 234, from Time Force II Hardware Guide

The original document is the PDF (1.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Qqest V800

Page 35

TimeForce II Hardware Guide

23

IntelliClock Setup Instructions IntelliClocks have all the basic Time & Attendance features of the ETC 100 clock model, as well as the option for Departmental, Quantity, and Tips entry, plus Job and Task tracking. These premium options are purchased separately so that you may configure the clock to suit your needs. If you do not purchase an option with the clock, but decide to add it later, you may do so at any time. Contact the Qqest Sales Department to enable options on your IntelliClock. The Bell/Buzzer, Daisy, and Modem options can also be used with IntelliClocks. Contact a Qqest Sales Representative if you wish to use one of these options with your IntelliClock. In addition, the IQ 1000 model features biometric capabilities. Employees clock in using a bar code, magnetic card, or keypad entry, then verify their identity using finger template identification. IntelliClocks are available with the following communication options, Serial, Serial Daisy, Modem, Ethernet, and Wireless. Each clock model is explained in more detail later in this chapter.

Creating a Time Clock Profile Before the ClockLink utility will be able to connect to your time clock, you must first create a profile for the clock within the TimeForce program. Clock profiles are created from the main “Clocks” section of the TimeForce software. Note: The following instructions focus primarily on IQ 300, 400 and 500 model clocks. See page 51 for detailed instructions on setting up an IQ 1000 clock profile. 1.

Open the TimeForce software and log in as a user with administrative rights.

2.

Click on the main “Clocks” navigation tab at the top of the screen.

3.

To create a new clock profile, click on the [ADD CLOCK] icon located under the New Clocks header on the left-hand side of the screen.

IntelliClock Setup Instructions

Page 36

24

Qqest Software Systems, Inc.

4.

Select the appropriate clock model from the Model drop-down menu (as in “IQ400,” “IQ500,” “IQ1000,” etc.).

5.

The clock Number is also known as the Clock ID. This number is assigned in the memory of the clock itself. The default number is “1.”

6.

Enter the clock Password. This password is also assigned in the memory of the time clock. The default password for an IQ 300, 400 or 500 clock is “ETC.” The default password for an IQ 1000 clock is “IQ 1000.”

7.

If you would like to restrict it so that only a specific range of card numbers will be accepted at the time clock, enter the desired range into the Card Range fields.

8.

Enter a Description for this clock as you would like it to appear in TimeForce II and ClockLink.

9.

If you would like to assign this clock to a group, make the desired selection from the Clock Group drop-down menu. Note: See page 211 for instructions on creating clock groups.

10. If you would like to assign this clock to a Default Department, click on the “No Department” link and make the desired selection from the tree-directory that appears. 11. If you would like to upload relay events to the time clock, put a check-mark in the Upload Relay Events field. Note: Relay Events can only be accessed once the clock profile has been saved. 12. Select the Time Zone that the clock resides in from the drop-down menu. 13. Enter any desired Notes about the clock profile. 14. Select the Connection Type from the drop-down menu. The steps to completing the clock profile vary slightly depending on what connection type you are using. •

Ethernet Clock: Put a check mark in the DHCP option to use Dynamic Host Configuration Protocol. Otherwise, enter the IP Address where the clock can be reached. Remember to use periods. If the clock can only be reached using a specific port number, enter the appropriate port into the Port Number field. Leave this field blank to use the default port.

Page 37

TimeForce II Hardware Guide

•

•

25

Note: These settings are specific to your network setup. Qqest Software Systems cannot supply these settings. Serial Clock: Select the Com Port that the clock is connected to from the drop-down menu. Select “Auto Detect” to have the system automatically determine which port the clock is connected to. Modem Clock: In the Phone Number field, enter the phone number of the line that the clock is connected to. Enter the number exactly as you would dial it into a telephone, including any necessary area code or extension numbers. Do not use dashes or brackets. Example: A phone number of (800) 555-4855 would be entered as “18005554855.”

When you have finished entering clock information, click on the [CREATE] icon to add the time clock profile.

Editing and Deleting Existing Clock Profiles Time clock profiles are displayed in the “Clock Settings” section of the TimeForce program. 1.

Open the TimeForce II program and log in as an administrator-level user.

2.

Click on the main “Clocks” navigation tab at the top of the screen.

3.

From the Existing Clocks section of the screen, click on the [EDIT/ VIEW] icon.

4.

If you would like to view clock profiles belonging to a specific clock group only, make the desired selection from the Group Name drop-down menu. Select “All” to display all time clock profiles.

5.

The Sort by fields allow you to select how the displayed list of clock profiles are sorted.

6.

Click on the [DISPLAY] icon to view time clock profiles.

7.

Clock profiles are displayed under the Clock List section of the screen. The following information is displayed for each profile.

IntelliClock Setup Instructions

Page 38

26

Qqest Software Systems, Inc.

•

• • •

• • •

•

Number: This is the ID of the displayed time clock. The setting in this field is a link. Click on the link to bring up the profile for this clock. Model: This column displays the clock model (as in “IQ400,” “IQ1000,” etc.). Connection Type: This is the type of connection that the time clock uses (as in “Serial,” “Ethernet,” “Modem,” etc.). Method: This is the additional information entered, based on the connection type (as in the com port selected, or the phone number entered, etc.). Group: If the time clock is assigned to a clock group, this field displays the name of the group that the clock is assigned to. Description: This is the description that was inserted when the clock profile was created. Relay Events: If you selected the “Upload Relay Events” option when creating the clock profile, a “View” link appears in this field. Click on the link to manage Relay Events for the clock. Click on the icon to remove a clock profile from the system.

Hardware Installation Use the following instructions to place your time clock in the desired location and to install communications with the clock. Follow the instructions below that correspond with the type of communication that your clock uses. Once you have installed your time clock, refer to the following sections for model-specific usage instructions: • •

“Using the Model IQ 300, 400 or 500 IntelliClock” on page 35 “Using the Model IQ 1000 IntelliClock” on page 51

Page 39

TimeForce II Hardware Guide

27

Serial Clocks The IntelliClock should be placed in a convenient location where employees typically enter and exit the work area. It includes a mounting panel with four holes. Mounting screws are included. Once the mounting panel is attached to the wall, the clock’s face can be snapped into place and locked onto the mounting panel. 1.

Attach the IntelliClock mounting panel to the wall with the provided mounting screws.

2.

Connect the power cord to the bottom of the IntelliClock and plug it into the closest available electrical (110-120 VAC) outlet. Note: It is highly recommended that you place the time clock on a battery backup or surge protector. Power surges can permanently damage the clock.

3.

Connect the RJ-11 connector of the cable (the one that looks like a phone-jack) into the port labeled “PHONE/COMPUTER/DAISY” on the bottom of the time clock.

4.

Snap the IntelliClock face piece into place on the mounting panel and lock it in with the two locks located on the bottom of the mounting panel.

5.

Connect the RS-232 end of the cable (the 9-pin D-Connector) into an available serial port on your computer.

Modem Clocks The IntelliClock includes a mounting panel with four holes. Mounting screws are included. Once the mounting panel is attached to the wall, the clock’s face can be snapped into place and locked onto the mounting panel. 1.

Attach the IntelliClock mounting panel to the wall with the provided mounting screws.

2.

Connect the power cord to the bottom of the IntelliClock and plug it into the closest available electrical (110-120 VAC) outlet. Note: It is highly recommended that you place the time clock on a battery backup or surge protector. Power surges can permanently damage the clock.

IntelliClock Setup Instructions

Page 40

28

Qqest Software Systems, Inc.

3.

Insert one of the square, plastic RJ-11 connectors of the Telephone Adapter Cable into the port on the bottom of the time clock labeled “PHONE/COMPUTER/DAISY.”

4.

Snap the IntelliClock face piece into place on the mounting panel and lock it in with the two locks located on the bottom of the mounting panel.

5.

Insert the other RJ-11 connector into an active analog telephone wall-jack.

Ethernet Clocks The ethernet clock includes a mounting panel with four holes. Mounting screws are included. Once the mounting panel is attached to the wall, the clock’s face can be snapped into place and locked onto the mounting panel. 1.

Attach the clock mounting panel to the wall with the provided mounting screws.

2.

Connect the power cord to the bottom of the IntelliClock and plug it into the closest available electrical (110-120 VAC) outlet. Note: It is highly recommended that you place the time clock on a battery backup or surge protector. Power surges can permanently damage the clock. For instructions on connecting a PoE clock, see page 189.

3.

On the back of the clock, you’ll see a panel cut out of the clock case. The ethernet port is located in the upper left-hand corner of this cutout section, directly above the clock relays (labeled “BELL” and “DOOR”). Plug one end of the Standard Category 5 (CAT5) cable into the Ethernet port.

4.

Connect the other end of the CAT5 cable to your network. The cable used to connect the clock must be a straight-through cable, not a crossover. To tell the difference between a straight-through and a crossover cable, hold the connectors side by side, with the same side of each connector facing you. Look at the wires inside of the connector. If the colors of the wires run in identical order from left to right in both connectors, the cable is a straight-through. If the colors run in opposite order, the cable is a crossover.

Page 41

TimeForce II Hardware Guide

29

Configuring the Ethernet Clock The Ethernet clock uses Ethernet Settings, an ID and a Password for communication. The Ethernet Settings include an IP Address, Subnet Mask and Gateway. These settings are comparable to giving the clock an “address” at which it can be found over the network. Consult your Network Administrator about acquiring these settings. Note: The clock must be given a static IP address that is reserved for the clock alone. 1.

From the clock’s keypad, press the <MENU> button, enter your password (the default password is “1111”), and press <ENTER>.

2.

Press 1 for System Maintenance.

3.

Press 3 for Ethernet.

4.

Press 1 to set the IP address, press 2 to set the Subnet Mask, or press 3 to set the Gateway. Selecting any one of these options will bring you to an Ethernet Settings menu. The current setting will be displayed, and the clock will prompt you to enter the new setting.

5.

Enter the new setting at the keypad (remember to use the Period key), and press <ENTER>. To exit the menu without making changes, simply press the <ENTER> key.

Important: The Ethernet Settings are specific to your Local Area Network. You must change the default settings. Qqest Technical Support cannot supply these settings.

Configuring the Wireless Time Clock If you have a wireless IQ 1000 Ethernet clock, use the following section to configure your clock for wireless communication. The wireless time clock supports the following communication protocols: 802.11 a and b. The optimum communication range for the wireless time clock is 50 100 feet from the wireless access point. Some wireless access points advertise communication up to 1000 feet. Regardless of this specification, Qqest Software Systems cannot guarantee communication at a distance of over 100 feet.

IntelliClock Setup Instructions

Page 42

30

Qqest Software Systems, Inc.

The following settings must be specified before your time clock will communicate: • • • •

IP Address Subnet Mask Gateway SSID

These settings are specific to your network setup. Qqest Software Systems cannot supply these settings. 1.

From the clock keypad, press the <MENU> button and select “Admin.”

2.

Enter an administrator ID (or Card #) and press the <ENTER> key. Note: The default administrator ID is “8888.”

3.

Enter the password (or PIN) for the entered administrator ID and press the <ENTER> key. Note: The password for the default admin ID is “1111.”

4.

From the Main Admin Menu, press 1 for “System Maintenance.”

5.

Press 3 for “Ethernet.” This menu contains the time clock’s ethernet options.

Set IP Address From the Ethernet Menu, press 1 for “Set IP Address.” The following prompt appears: SET NEW IP ADDRESS: CURRENTLY: ENTER NEW IP: The “Currently” field displays the current IP address. To change the clock IP address, type in the new address at the clock keypad (remember to use the period key) and press <ENTER>.

Page 43

TimeForce II Hardware Guide

31

Set Subnet Mask From the Ethernet Menu, press 2 for “Set Subnet Mask.” The following prompt appears: SET NEW SUBNET MASK: CURRENTLY: ENTER NEW MASK: The “Currently” field shows the current Subnet Mask. To change the mask, type in the new setting at the clock keypad (remember to use the period key) and press <ENTER>. Set Gateway From the Ethernet Menu, press 3 for “Set Gateway.” The following prompt appears: SET NEW GATEWAY: CURRENTLY: ENTER NEW GATEWAY: The “Currently” field shows the current Gateway. To change the Gateway, type in the new setting at the clock keypad (remember to use the period key) and press <ENTER>. Set SSID The SSID is the ID of the wireless access point that the clock will connect to. 1.

From the Ethernet Menu, press 6 for “Wireless Settings.”

2.

Press 1 for “Enter SSID.” The following prompt appears: ENTER WIRELESS ID: (SSID) (ALPHANUMERIC ENTRY)

3.

Use the grey buttons above the clock keypad to enter the ID of the wireless access point and press <ENTER>.

Note: See page 82 for further instructions on wireless settings.

IntelliClock Setup Instructions

Page 44

32

Qqest Software Systems, Inc.

How Do I Find the Clock ID and Password? The clock ID and password are stored in the time clock itself. These settings can be changed from ClockLink once you have connected to the time clock, but you must specify the clock's current ID and password before a connection can be made. Note: The default clock ID is “1.” The default clock password is “ETC.” The following procedures are performed at the keypad of the clock itself. Finding the Clock ID 1. On the clock keypad, press the <MENU> button. 2.

Enter an administrator password and press <ENTER>. Note: The default admin password is “1111.”

3.

Press 1 for “System Maintenance.”

4.

Press 2 for “Memory.”

5.

Press 3 for “Set Clock ID.” The “Set New Clock ID” screen opens.

6.

The “Currently” field displays the clock's current ID. If you would like to change the clock ID, enter the desired number at the keypad and press <ENTER>.

You can now exit the time clock menu by pressing <CLR> repeatedly until “Ready” is shown on the clock display. Finding the Clock Password 1. On the clock keypad, press the <MENU> button. 2.

Enter an administrator password and press <ENTER>. Note: The default admin password is “1111.”

3.

Press 3 for “Passwords.”

4.

Press 3 for “Clock/Modem.” The “Passwords” screen opens.

5.

The current clock password is not displayed. Type in a new password at the keypad and press <ENTER>.

6.

Re-type the new password and press <ENTER>.

You can now exit the time clock menu by pressing <CLR> repeatedly until “Ready” is shown on the clock display.

Page 45

TimeForce II Hardware Guide

33

Uploading the Date and Time Before you can begin using your time clock, you must first upload the date and time to the clock using the ClockLink utility. Note: Before you will be able to upload the date and time, you must first create a time clock profile in TimeForce II for each clock that you would like to connect to. See “Creating a Time Clock Profile” on page 17 for more information. 1.

Open the ClockLink utility. From the Windows Start Menu go to Programs | TimeForce II and click on “ClockLink.”

2.

Each time clock that has been set up in the TimeForce software is listed in the left-hand section of the screen. Highlight the clock that you would like to upload the date and time to and click on the “Connect” link.

3.

Once communication has been established with your time clock, the right-hand section of the screen opens. From the row of tabs at the top of the screen, ensure that [PARAMETERS] is selected.

4.

From the Actions section of the screen, click on the icon. The “Upload Date/Time” screen opens. •

•

•

5.

Enter the desired Date. By default this field is populated with the system date of the machine that the ClockLink is installed on. Click on the down-arrow icon at the end of the field to select the date from a calendar. Enter the Time. By default this field is populated with the system time of the machine that ClockLink is installed on. Click on the up and down arrow keys at the end of the field to select the time, or place your cursor in the field and manually type the desired time. Put a check mark in the Use System Time option to send the computer's system date and time to the clock. With this setting enabled, the “Date” and “Time” fields are grayed-out.

Click on the [OK] icon to send the date and time to the clock.

You can now exit the ClockLink utility.

IntelliClock Setup Instructions

Page 46

34

Qqest Software Systems, Inc.