What is in it
Technical description of the SICK LSI 101 laser scanner interface, which works with one or more PLS laser scanners to guard danger zones and vehicles. It covers safety advice, how the LSI works, area and vehicle protection, system planning, the supply package, installation and wiring to the control, power supply and a PC, programming monitoring areas and cases with the PLS/LSI user software, tests, care and maintenance, and an appendix with application examples, technical data, accessories and drawings.
Its parts
- General safety advice and protective measures
- Approvals and certificates
- Information for correct use
- How the LSI functions
- Application of the LSI
- Planning the LSI system
- Supply package
- Installing the LSI
- Connecting the LSI
- Programming the LSI – User software
- Tests
- Care and maintenance
- Appendix
- Glossary
From the manual
Key facts from this manual
Each line names its page in the PDF.
This is the SICK technical description for the LSI 101 Laser Scanner Interface, types LSI 101-11X, which connect up to four PLS laser scanners. It covers planning, installing and wiring the LSI, programming it with the PLS/LSI user software, tests, fault codes, technical data and accessories with part numbers.
- Variants
- LSI 101-112 for up to 2 PLS 101-3xx scanners; LSI 101-114 for up to 4 p. 78
- Supply voltage
- 24 V typical (16.8 V to 28.8 V), from a safety isolating transformer to EN 60742 p. 72
- Power consumption
- 15 W without PLS and no load; 63, 80, 97 or 114 W with 1, 2, 3 or 4 PLS at maximum load p. 72
- Safety outputs
- 2 independent monitored 2-channel outputs, PNP high-active, 24 V/250 mA p. 77
- Inputs
- 4 static binary input pairs A1, A2 to D1, D2, or 2 incremental encoder inputs C, D plus pairs A and B p. 77
- PC interface
- RS 232 (up to 15 m) or RS 422 (up to 100 m), 9600, 19200 or 38400 baud, for temporary configuration only p. 77
- LSI to PLS link
- RS 422 at 500 kB over Li2YCY twisted pair cable, up to 30 m p. 77
- Software
- PLS/LSI user software from version 03.21 (16-bit) or 03.61 (32-bit), supplied with the PLS on 3.5 inch floppy disk p. 11
- Connection sets
- Set A 2 019 065 without cable; sets B to G with 3, 5, 10, 15, 20 or 30 m cable: 2 019 066 to 2 019 070 and 2 025 902 p. 11
- Power supply units
- 24 V DC 2.5 A 6 010 361; 24 V DC 4.0 A 6 010 362; 24 V DC 10 A 6 011 156 p. 78
- Other accessories
- Mounting kit 2 019 300; WAGO terminal strip set 2 018 946; Sub-D connector, screw-in 6 011 808 or soldered 2 019 097 p. 78
- Fault codes
- 11 to 21: PLS to LSI communication failure; 41: sensor fault; 120 to 123: dirt on sensor 1 to 4; 200 to 203: same level at input A to D p. 61, 62, 63
- Dimensions and weight
- 216 mm x 108 mm x 86 mm without terminals and connectors; 1.25 kg p. 76
- In the box
- LSI, the ordered connection set, a DIN rail bracket, two wall brackets, the manuals and 10 plug-in connectors p. 11
What this manual walks you through
- Wiring the LSI to the PLS scanners p. 13
- Connecting inputs, outputs and the 24 V supply p. 14, 15
- Connecting restart buttons and external device monitoring p. 15
- Connecting a PC over RS 232 or RS 422 p. 17
- Defining monitoring areas and cases with the user software p. 3
- Adapting protective fields to speed p. 3
- Calibrating contamination measurement after a front screen change p. 60
- Reading the LSI and PLS LEDs p. 60
- Looking up fault codes and their fixes p. 61, 62, 63
Good to know
- Each safety output may drive only one switching element; more need contact expansion. p. 14
- With incremental encoders in use, binary inputs C and D are not available. p. 14
- No user software comes with the LSI. p. 11
- Contamination measurement may only be calibrated directly after the front screen is replaced. p. 60
- Fault codes not in the table are internal faults that need SICK Service. p. 61
Questions this manual answers
What does LSI fault code 11 to 21 mean?
A communication failure between the PLS and the LSI. Check the communication cable, then switch the power off and on again. p. 61
What does LSI fault code 200 mean?
Both channels of input A have the same level. A1 and A2 must always carry mutually inverted levels. p. 63
What software programs the LSI 101?
The PLS/LSI user software, version 03.21 (16-bit) or 03.61 (32-bit) and later, which is supplied with the PLS. p. 11
What is the LSI 101 response time?
190 ms at a 2 scan rate; for more scans it is 110 ms plus 40 ms per scan. p. 72
Which power supply units fit the LSI?
The accessory list gives 24 V DC units of 2.5 A (6 010 361), 4.0 A (6 010 362) and 10 A (6 011 156). p. 78