Page 71

Restart after intrusion into the protective field You have the following options, programmable in the PLS/LSI user software (see section 9.3): – Without delay – Delayed by n seconds – With restart button Restart “without delay”: As soon as the active protective field is free, the LSI enables the output after the pre-set response time (multiple scans). The red LED at the configured output (OSSD A or B) goes out and the green LED lights up.

Red Yellow

Red

Green Yellow Green

RES

OSSD WEAK/

A

Yellow

OSSD

RES

B

ERROR

Restart “delayed by x seconds”: The LSI starts up when the preset time has expired after the protective field has become free. At the end of this time, the red LED at the configured output goes out and the green LED lights up. The output is then free.

After x seconds:

Red Yellow

Red

Green Yellow Green

RES

OSSD WEAK/

A

Yellow

OSSD

RES

B

ERROR

Restart “with restart button”: The yellow “RES” LED at the configured output flashes. You must then press the restart button. Only then is the output enabled.

Red Yellow

Red

Green Yellow Green

Yellow

Note: When mounting the restart buttons, make sure the button is mounted such that the danger zone is in full view when the button is pressed. The system is then ready for operation.

RES

OSSD WEAK/

A

ERROR

OSSD

RES

B

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

71

Page 72

12.3 Technical data Here you will find the key technical data of the LSI. Notes: Also refer to the technical data of the PLS contained in the PLS Technical Description. The requirements for the cables to be used are set out in section 8 of this Technical Description and in the LSI Operating Instructions, section 4.3, “Cable requirements”.

Properties

Specifications typ. max.

Comments min. 16.8 V

24 V

28.8 V

Protected against polarity reversal by a safety isolating transformer to EN 60742

Permissible residual ripple

500 mV

The upper and lower voltage limits must not be infringed.

Cable length

50 m

Cable cross-section

2.5 mm2

Permissible cable resistance

2.5 Ohm

Power supply connection (Uv)

Response time (adjustable) at 2 scan rate

190 ms

Formula for multiple scans (n = 2 to 16)

110 ms + ( n x 40 ms ) Exception: PLS 101-316 with LSI in vehicle protection applications, where the response time is 270 ms, non-adjustable

Power-up time On power-on

9 sec.

Power consumption without PLS and no load

15 W with 1 PLS and max. load

63 W with 2 PLS and max. load

80 W with 3 PLS and max. load

97 W with 4 PLS and max. load

114 W See PLS technical data Connect only PLS units of the same types

PLS connection RES A, RES B (Reset/Restart input) Quantity

One input per OSSD pair

Input resistance at HIGH

3.8 kOhm

Voltage for HIGH

15 V

28.8 V

Voltage for LOW

0V

1V

Start pulse current (where t = 100 µs)

15 mA

32 mA

Static input current

3.5 mA

9 mA

Current consumption

72

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

Page 73

Properties min.

Specifications typ. max.

Comments

Time response of reset/restart button LOW level before actuation

160 ms

HIGH level during actuation

240 ms

LOW level after actuation

160 ms

5s

Cable length

50 m

Cable cross-section

2.5 mm2

Permissible cable resistance

2.5 Ohm

EDM input (external device monitoring) Quantity

One input per OSSD pair

Input resistance at HIGH

3.8 kOhm

Voltage for HIGH

15 V

28.8 V

Voltage for LOW

0V

1V

Start pulse current (where t = 100 µs)

15 mA

32 mA

Static input current

3.5 mA

9 mA

Current consumption

Time response of EDM input High level after OSSD activation

200 ms

Low level on OSSD deactivation

200 ms

Cyclic monitoring of the rest and operating positions

5s

Cable length

50 m

Cable cross-section

2.5 mm2

Permissible cable resistance

2.5 Ohm

Inputs A, B (2-channel: A1, A2/B1, B2 antivalent), static binary Input resistance at HIGH

3.8 kOhm

Voltage for HIGH

15 V

28.8 V

Voltage for LOW

0V

1V

Start pulse current (where t = 100 µs)

15 mA

32 mA

Static input current

3.5 mA

9 mA

Current consumption

Port inconsistency Time window for valid switchover ... (at 2 scan rate)

80 ms

Cable length

50 m

Cable cross-section

2.5 mm2

Permissible cable resistance

2.5 Ohm

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

73

Page 74

Properties min.

Specifications typ. max.

Comments

Inputs C, D (2-channel: C1, C2/D1, D2 antivalent), static binary Input resistance at HIGH

2.6 kOhm

Voltage for HIGH

15 V

28.8 V

Voltage for LOW

0V

1V

Start pulse current (where t = 0.5 µs)

15 mA

32 mA

Static input current

5 mA

13 mA

Current consumption

Port inconsistency Time window for valid switchover (at 2 scan rate)

80 ms

Cable length

50 m

Cable cross-section

2.5 mm2

Permissible cable resistance

2.5 Ohm

Inputs C, D (only for incremental encoder 0°/90°), dynamic Input resistance at HIGH

2.6 kOhm

Voltage for HIGH

15 V

28.8 V

Voltage for LOW

0V

1V

Start pulse current (where t = 0.5 µs)

15 mA

32 mA

Static input current

5 mA

13 mA

Current consumption

Duty factor g (Ti/T)

0.5

Input frequency

100 kHz

Min. number of pulses per cm

50

Evaluable speed range

±10 cm/s

±2000 cm/s

Tolerance time for differing directional information or signal failure of an incremental encoder

0.4 s

³ 10 cm/s

Exceeding of speed tolerance where incremental encoders in same direction

20 s 60 s

< 30 cm/s

Cable length

50 m

Cable cross-section

2.5 mm2

Permissible line impedance

2.5 Ohm

³ 30 cm/s

Warning field output A/B (PNP), HIGH-active Quantity

One output per OSSD pair

Switching voltage HIGH-active at 50 mA

Uv -1 V

Uv

Switching voltage HIGH-active at 100 mA

Uv -0.5 V

Uv

Switching current (referred to EXT_GND)

74

100 mA

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

Page 75

Properties min. Current limitation ( t = 5 ms, 25 degrees Celsius)

Specifications typ. max.

600 mA

920 mA

Pure load inductance

2H

Switching sequence

6 1/s

Response time ( n = 2 to 16 ; n = scan rate)

Comments

150 ms + ( n x 40 ms )

Cable length

50 m

Cable cross-section

2.5 mm2

Permissible cable resistance

2.5 Ohm

Error output (PNP), HIGH-active Quantity

One output

Switching voltage HIGH-active at 50 mA

Uv -1 V

Uv

Switching voltage HIGH-active at 100 mA

Uv -0,5 V

Uv

Switching current (referred to EXT_GND) Current limitation ( t = 5 ms, 25 degrees Celsius)

100 mA 600 mA

920 mA

Pure load inductance

2H » 4 /s 1

Switching sequence Cable length

50 m

Cable cross-section

2.5 mm2

Permissible cable resistance

2.5 Ohm

Safety outputs (OSSD A, OSSD B), dynamic, High-active Quantity

Two 2-channel outputs

Switching voltage High-active (Ueff)

Uv -3,4 V

Uv

Voltage for LOW

0V

2.5 V

Switching current (reference to EXT_GND) 2 mA Short-circuit protected

250 mA by monitoring of outputs

In case of fault: Leakage current

1.1 mA

Pure load capacity

100 nF

Pure load inductance

2H

Switching sequence (without switchover and without simultaneous monitoring)

6 1/s

Response time at double speed

190 ms

Cable length

50 m

Break in GND cable. The downstream switching element must detect this state as Low.

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

75

Page 76

Properties min.

Specifications typ. max.

Cable cross-section

2.5 mm2

Permissible cable resistance

2.5 Ohm

Comments

Test pulse data (OSSD_Test) Test pulse width

100 µs

Test frequency

Once per scan

Test pulse data (Test_Ub) Test pulse width

100 µs

Test frequency

Twice per scan

Safety category

Single error fail-safe

DIN V 19250

Requirement class 4

EN 954-1

Category 3

IEC/EN 61496-1

Type 3

General data IP 20

Enclosure rating Protection class

3 Safety-low voltage

Humidity class

F to DIN 40040

Vibration resistance

IEC 60068, part 2-6

Frequency range

10 ... 55 Hz

Amplitude

0.35 mm IEC 60068, part 2-29

Shock resistance Continuous shock 1000

10 g / 16 ms

Interference immunity (EMC)

IEC / EN 61496-1 EN 50081-2 DIN 40839-1 and -3

Mass (net)

1.25 kg

Dimensions (W x H x D)

216 mm x 108 mm x 86 mm

Operating temperature in degrees Celsius

0

Storage temperature in degrees Celsius -25

76

Installation in switch cabinet with min. IP 54 specified.

Dimensions excluding terminals and connectors +50 +70

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

Page 77

Properties min.

Specifications typ. max.

Protective fields

1

8

Warning fields

1

8

Protective field output

2 independent, monitored semiconductor outputs, 2-channel, PNP HIGH-active, 24 V/250 mA

Warning field output

2 independent semiconductor outputs, PNP HIGH-active, 24 V/100 mA

Fault output

1 semiconductor output, PNP HIGH-active, 24 V / 100 mA

Reset/restart input

1 input per OSSD pair (to 24 V DC)

Comments

EDM input (external device monitoring) 1 input per OSSD pair (to 24 V DC) Inputs A1, A2, B1, B2, C1, C2, D1, D2

Static binary inputs to 24 V DC

Inputs C, D

Dynamic inputs to 24 V DC

Switchover of monitoring cases (use of inputs A - D)

4 static binary input pairs (x1 and x2 antivalent) A1, A2, B1, B2, C1, C2, D1, D2 or 2 dynamic incremental encoder inputs (C, D) and 2 static binary input pairs (x1 and x2 antivalent) A1, A2, B1, B2 Only for temporary configuration and diagnostic purposes

Interface (PC) Transmission rate RS 232

9600, 19200, 38400 Baud

RS 422

9600, 19200, 38400 Baud

Cable length RS 232

15 m

RS 422

100 m Use of a low-capacitance twisted-pair data cable of type Li2YCY (TP) with a cable cross-section of min. 2 x 2 x 0.25 mm2

Interface (LSI - PLS)

Transmission rate RS 422

500 kB

Cable length RS 422

30 m

Cable cross-section RS 422

0.25 mm2

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

77

Page 78

12.4 Accessories

User documentation

For installation

Technical Description LSI, German, without software discs

Part no. 8 008 309

Technical Description, LSI, English, without software discs

8 008 310

Technical Description, LSI, French, without software discs

8 008 311

Technical Description LSI, Spanish, without software discs

8 009 033

Mounting kit (DIN rail and mounting bracket)

Part no. 2 019 300

LSI variants LSI 101-112 (for connection of max. 2 PLS 101-3xx) LSI 101-114 (for connection of max. 4 PLS 101-3xx)

Part no. 1 016 063 1 016 065

For connection to the control and the PLS Connection set A 1 PLS power plug, 1 PLS interface connector, 1 screw-in interface connector for sensor connection to LSI, without cable

Part no.

2 019 065

Connection set B, as connection set A, with 3 metre cable

2 019 066

12.5 Standards and regulations The following lists the key standards and regulations applicable to the use optoelectronic safety devices. Depending on application, additional regulations may be of importance for you. You can get information on other device-specific standards from local regulatory authorities, or from professional bodies. Regarding the use and installation of safety devices:

Connection set C, as connection set A, with 5 metre cable

2 019 067

Machinery Directive 98/37 EC

Connection set D, as connection set A, with 10 metre cable

2 019 068

Safety of machines – Basic terms, general design guidelines (EN 292)

Connection set E, as connection set A, with 15 metre cable

2 019 069

Safety requirements for automated manufacturing systems (VDI 2854)

Connection set F, as connection set A, with 20 metre cable

2 019 070

Safety of machines – Electrical equipment of machines – Part 1: General requirements (EN 60 204)

Connection set G, as connection set A, with 30 metre cable

2 025 902

Safety of machines – Safety distances to prevent reaching hazardous areas with upper limbs (EN 294)

Terminal strip set, WAGO connector set, 8-part

2 018 946

Safety requirements for robots (EN 775)

SUB–D connector (RS 232/RS 422) with screw-in terminals, EMC protected

6 011 808

Safety rules for electro-sensitive protective equipment on powerdriven machinery (ZH 1 / 597)

SUB–D connector (RS 232/RS 422) with soldered terminals, EMC protected

2 019 097

Safety of machines – Arrangement of safety devices with regard to approach speed of body parts (EN 999) Safety of machines – Risk assessment (EN 1050)

Power supply units Part no. 24 V DC, 2.5 A

6 010 361

Regarding construction and equipping of protective devices:

24 V DC, 4,0 A

6 010 362

24 V DC, 10 A

6 011 156

Safety of machines – Electro-sensitive protective equipment – Part 1: General requirements (IEC/EN 61496-1)

Interface cables RS 232

Part no.

Basic safety observations for instrumentation and control protective devices (DIN V 19 250) Safety of machines – Electrical equipment of machines – Part 1: General requirements (EN 60 204)

Interface cable, 3 m

2 016 401

Interface cable, 5 m

2 016 402

Interface cable, 10 m

2 016 403

Safety of machines – Safety-related components of controls – Part 1: General design guidelines (EN 954)

Interface cable, 3 m

2 019 130

On these subjects please also order our brochure “Safe machines with optoelectronic protection devices”.

Interface cable, 5 m

2 019 131

Interface cable, 10 m

2 019 132

RS 422

78

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

Page 79

OSSD A2

K5 K6 K1 K2

ERROR

A

X15

WZ A

POWER IN

OSSD A1

_ _ + DC 24 V

LSI

B

POWER OUT

+

X14

WZ B

_

OSSD B1

_ _ + _ DC 24 V

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

X13

DC24 24 V DC

K2

K1

A

B

RES

POWER OUT

+

EDM A

DC 24 V

RES A

+

OSSD B2

X3

EDM B

X2

RES B

X1

A

OSSD

OSSD

A1

SENSOR

SENSOR

B1

X12

A2

INPUT B2

ERROR

D1

X11

C1 C2

INPUT

B

2

1

WEAK/

X5

X4

D2

RES

OR

SENSOR

3

X6

RS 422

OR

RS 232

COM

X8

X10

C

X9

D

SPEED INPUT SPEED INPUT

SENSOR

4

X7

12.6 Connection diagram

79

Page 80

12.7 Dimensional drawing min. 75

(all dimensions in mm)

X2 _

24

+

V

POWER IN

_

+

X3 _

_

+

+

X4

X5

X6

X7

X8

1

2

3

4

COM

SENSOR

SENSOR

SENSOR

SENSOR

RS 232

_

D C 24 V

DC 2 4 V

POWER OUT

POWER OUT

LSI

OR

R ES

O SSD

A

X15

B

A

O SSD

R ES

RS 4 2 2

B

B

X14

A

B

X13

RES B

ED M

R ES A

ED M

O SSD B2

O SSD B1

OR

WZ B

O SSD A 2

ERR O R

O SSD A 1

WZ A

A

WEA K/ ER RO R

INPUT A1

A2

B1

INPUT B2

X12

C1

C2

D1

X11

SPEED INPUT D2

SPEED INPUT

C

D

X10

X9

13

86

7

216 min. 75

_ DC

108

X1 +

226

80

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved