Operating instructions for the SICK LSI 101 Laser Scanner Interface, which works with PLS laser scanners as a personnel protection system on vehicles and industrial plant. The same manual is printed in many languages, including German, Danish, Spanish, French, Finnish, English, Greek and Italian. Each language covers the system description, safety rules, mounting, cabling requirements, commissioning, tests and checklist, diagnosis, accessories, declaration of conformity and full technical data.
Its parts
- General
- System description
- Safety regulations and instructions
- Mounting
- Notes on commissioning
- Tests
- Diagnosis
- Accessories
- Declaration of Conformity
- Technical Data, LSI
- Appendix: Key to diagrams
From the manual
Key facts from this manual
Some pages are scans or cannot be read; this says only what the readable text supports. Each line names its page in the PDF.
These are the multilingual operating instructions for the SICK LSI 101 Laser Scanner Interface (type LSI 101-11X), which runs up to four PLS laser scanners as one protective sensor system. This summary draws on the English section, which covers mounting, wiring, tests, the diagnostic LEDs and the technical data.
- Device
- Interface that runs up to four PLS laser scanners at once for personal protection on vehicles and plant p. 137
- Type designation
- LSI 101-11X, where the last digit (1 to 4) is the maximum number of connectable sensors p. 136
- Monitoring areas
- Up to eight protective and warning fields stored in non-volatile memory p. 137
- Supply voltage
- 24 V typical, 16.8 V minimum, 28.8 maximum p. 152
- Power consumption
- 15 W without PLS and no load; 63, 80, 97 or 114 W with 1, 2, 3 or 4 PLS at maximum load p. 152
- Safety outputs
- 2 independent monitored 2-channel OSSD outputs, PNP high-active, 24 V/250 mA p. 158
- Other outputs
- 2 warning field outputs and 1 error output, PNP high-active, 24 V/100 mA p. 158
- Inputs
- 4 static binary input pairs A1, A2 to D1, D2, or 2 incremental encoder inputs C, D plus pairs A and B p. 159
- Response time
- 190 ms at double speed p. 157
- PC interface
- RS 232 or RS 422 at 9600, 19200 or 38400 baud, for temporary configuration and diagnosis only p. 159
- LSI to PLS cable
- Shielded low-capacitance twisted pair, type Li2YCY, at least 2 x 2 x 0.25 mm2, up to 30 m p. 140
- Dimensions and weight
- 216 mm x 108 mm x 86 mm; 1.25 kg p. 158
- Mounting
- DIN rail (top-hat TS 35) in a switch cabinet or the supplied brackets; housing IP 20, cabinet at least IP 54 p. 139, 158
- Indicators
- Eight LEDs on top of the housing for OSSD status, error, reset and RS422 p. 148
What this manual walks you through
- Mounting the LSI on a DIN rail or with brackets p. 139
- Wiring the LSI and fitting the PLS connection boxes p. 139, 140
- Choosing cable types, cross-sections and lengths p. 140, 141
- Pre-commissioning, routine and daily tests of the protective device p. 143, 144
- Commissioning checklist for the machine builder p. 145, 146, 147
- Reading the LSI and PLS status LEDs p. 148, 149, 150
- Terminal and Sub-D pin assignments p. 160, 321
Good to know
- The safety outputs of the connected PLS units must not be used with the LSI. p. 139
- When the encoder inputs C and D are in use, the static inputs C1, C2, D1 and D2 are not available. p. 139
- Only PLS units of the same type may be connected. p. 152
- A PLS101-316 used with the LSI for vehicle protection has a fixed response time of 270 ms. p. 152
- Mounting and connection must be done only by qualified personnel. p. 137
Questions this manual answers
How many PLS scanners can an LSI 101 run?
Up to four at once. The last digit of the type designation LSI 101-11X gives the maximum number of sensors. p. 136, 137
How much power does the LSI 101 draw?
15 W with no PLS and no load, rising to 114 W with four PLS at maximum load. p. 152
What cable connects the LSI to a PLS scanner?
A shielded twisted pair data cable of type Li2YCY, at least 2 x 2 x 0.25 mm2, with the shield connected only at the LSI end, up to 30 m. p. 140
What do the LEDs on top of the LSI show?
Each safety output has a green and a red LED; a yellow LED shows errors or a dirty front screen, and RES A and RES B flash while a reset is awaited. p. 148
Where are ordering and programming details for the LSI?
The manual refers to the LSI Technical Description for ordering, system use and programming. p. 136
Contents
Chapters and sections
Each line opens the PDF at its page.
94 more lines, from page 86 on
The whole text · 37 parts
Read the manual here as text
Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.
- Deutsch, pages 1 to 101-10
- Deutsch, pages 11 to 2011-20
- Deutsch, pages 21 to 2821-28
- Dansk, pages 29 to 3729-37
- Dansk, pages 38 to 4638-46
- Dansk, pages 47 to 5447-54
- Español, pages 55 to 6355-63
- Español, pages 64 to 7264-72
- Español, pages 73 to 8073-80
- Français, pages 81 to 9081-90
- Français, pages 91 to 10091-100
- Français, pages 101 to 108101-108
- Suomi, pages 109 to 117109-117
- Suomi, pages 118 to 126118-126
- Suomi, pages 127 to 134127-134
- English, pages 135 to 143135-143
- English, pages 144 to 152144-152
- English, pages 153 to 160153-160
- Ελληνικά, pages 161 to 169161-169
- Ελληνικά, pages 170 to 178170-178
- Ελληνικά, pages 179 to 186179-186
- Italiano, pages 187 to 195187-195
- Italiano, pages 196 to 204196-204
- Italiano, pages 205 to 212205-212
- Norsk, pages 213 to 221213-221
- Norsk, pages 222 to 230222-230
- Norsk, pages 231 to 238231-238
- Nederlands, pages 239 to 247239-247
- Nederlands, pages 248 to 256248-256
- Nederlands, pages 257 to 264257-264
- Português, pages 265 to 274265-274
- Português, pages 275 to 284275-284
- Português, pages 285 to 292285-292
- Svenska, pages 293 to 301293-301
- Svenska, pages 302 to 310302-310
- Svenska, pages 311 to 318311-318