The text of a manual · part 17 of 37
Laser Scanner Interface LSI 101 Operating Instructions: English, pages 144 to 152
Pages 144 to 152 of 322, from Laser Scanner Interface LSI 101 Operating Instructions
The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick LSI-101
Page 144
GB
LSI
3. Daily testing of the protective device by authorised and instructed personnel: To test your LSI system correctly: 1. The test must be carried out for the relevant preset monitoring case. 2. Check the mechanical installation to ensure that all mounting screws are secure and that the PLS is properly aligned. 3. Check each PLS unit for visible changes, such as damage, manipulation etc. 4. Switch on the machine/plant. 5. Watch the LEDs on each PLS (red, green, yellow). 6. If at least one LED is not permanently lit when the machine/plant is switched on, it is to be assumed that there is a fault in the machine or plant. In this case the machine must be shut down immediately and checked by a specialist. 7. Deliberately obstruct the protective field without risk to any personnel while the machine is running in order to test the effectiveness of the entire system. The LEDs of each tested PLS unit must change from green to red and the hazardous movement must stop immediately. Repeat this test at different points in the danger area and on all PLS units. If you discover any non-conformance of this function, the machine/plant must be shut down immediately and checked by a specialist. 8. For stationary applications, check that the danger area marked out on the floor matches the shape of the protective field stored in the PLS and that any gaps are protected by additional safety measures. In the case of mobile applications, check that the moving vehicle actually stops at the field limits which are set in the LSI and listed on the data plate in the vehicle or in the configuration protocol. If you discover any non-conformance of this function, the machine/plant/vehicle must be stopped immediately and checked by a specialist.
144
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
Page 145
LSI
GB
9. This test replaces the test specified in the PLS Technical Description / Operating Instructions. Note for the operator The instructions concerning daily checking are also provided in the form of a self-adhesive label. Please affix the label in an easily readable location near the safety device in order to facilitate the daily checking procedure.
6.2 Checklist Checklist for machine manufacturer/installer for the installation of Electro Sensitive Protective Equipment (ESPE). Dependent upon the application, the below listed checks are a minimum when placing an ESPE in operation for the first time. For reference purposes the list should be retained or stored with the machine documents.
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
145
Page 146
GB 1.
LSI
Are the relevant safety standards incorporated into the machine build? Will they satisfy the Regulations? Yes o
No o
2. Are the standards listed in the Declaration of Conformity? Yes o
No o
3. Is the ESPE the correct Type and interfaced to the correct Yes o No o Category? 4. Is access to the danger zone / point of danger only possible Yes o No o through the ESPE? 5.
Are measures in place to prevent standing between the ESPE and the danger zone? If so, are these measures Yes o No o secured against removal?
6. Are all monitoring cases, which can be selected by way of the LSI designed such, that the measures in place as set out No o under item 5 remain effective? Yes o 7.
Are the mechanical means positioned to avoid reaching over, under or around? (see EN294)? Yes o
No o
8.
Has the overall machine stopping time been checked and Yes o No o documented?
9.
Is the resultant safety distance observed between the danger Yes o No o point and the ESPE?
10. Is the ESPE correctly fixed and secured against movement after setting in its fixed position? Yes o
146
No o
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
Page 147
LSI
GB
11. Are the required protection measures against electric shock Yes o No o in place?
12. Are the signals for switching monitoring cases for inputs A, B, C, D of the LSI two-channel (for more details see section 8.2, Yes o No o LSI Technical Description)? 13. Is the re-set / re-start switch for the ESPE installed and fitted Yes o No o to the correct standard? 14. Are the OSSDs of the ESPE connected in accordance with No o the machine circuit diagram? Yes o
15. Have the protective functions been inspected in accordance with the inspection instructions of this document? Yes o
No o
16. Are the switching elements controlled by the ESPE, e. g. No o contactors, valves monitored? Yes o 17. Is the ESPE effective during the entire hazardous state? Yes o
No o
18. Is the Daily Check Requirement sign positioned in a place Yes o No o visible to the operator? This checklist does not replace the initial commissioning or regular inspections by qualified personnel.
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
147
Page 148
GB
LSI
7. Diagnosis 7.1 Diagnostic elements Eight LEDs displaying the operating status of the LSI are located on the top of the LSI housing. Each safety output (OSSD A, OSSD B) is assigned a green and a red LED. The system status is signalled by the (yellow) ERROR LED. If operation with restart is defined, the two indicators RES A and RES B flash to indicate that the system is awaiting acknowledgement. If communication with the user (PC) has been reconfigured from RS232 to RS422, the yellow RS422 indicator is lit.
1: OSSD A inactive (red) 2: OSSD B inactive (red) 3: Front screen contamination PLS/System ERROR (yellow) 4: OSSD A active (green) 5: OSSD B active (green) 6: Reset/Restart (OSSD A) (yellow) 7: Reset/Restart (OSSD B) (yellow) 8: Communication configured to RS422 (yellow)
148
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
Page 149
LSI
GB
Diagnosis with LSI LEDs: Status
OSSD Weak/ (green) Error (yellow)
Protective field free Object in protective field Dirt contam. warning * Dirt Contamination * Fatal Error ** Startup testing Wait for reset
Res OSSD (yellow) (red)
1Hz »4Hz 1Hz
Diagnosis with PLS LEDs: Status
Green Yellow
Protective field free Object in protective field Dirt contam. warning * Dirt Contamination * Fatal Error ** Startup testing Wait for reset
Red
1Hz »4Hz 1Hz
Output level on LSI: Status
OSSD
Warning field
ERROR
Protective field free Warning field free Object in protective field Object in warning field Dirt contam. warning * Dirt Contamination * Fatal Error ** Startup testing Wait for reset
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
»4Hz
149
Page 150
GB * **
LSI If the PLS front screen gets dirty clean it with a soft cloth and plastic cleaner! System error: See section 7.2, Service! = LED lit 1 Hz = LED flashing slowly »4 Hz = LED flashing rapidly = Output switches to high = Output switches to low = Output is constant low »4 Hz = Output alternates between high and low
7.2 Service The LSI is maintenance-free on account of its fully electronic design. In case of faults, an initial diagnosis can be made on the basis of the LED information presented under 7.1. Also refer to the information in section 7.2, “Maintenance”, of the PLS Operating Instructions. Authorised personnel (see note in the PLS and LSI Technical Descriptions) have access to an extensive diagnostic system by means of the supplied user software. If you have any further questions please refer to your local SICK office or contact the SICK Service Hotline: +49 7681 / 202 - 3134
8. Accessories For a list of the suitable cable sets for PLS cabling to the LSI refer to the PLS or LSI Technical Description. The sections in those documents headed “Selection table for PLS/ LSI“ list all the articles necessary to ensure the correct use of the equipment.
150
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
Page 151
LSI
GB
9. Declaration of Conformity
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
151
Page 152
GB
LSI
10. Technical Data, LSI Specifications Supply voltage (Uv) Protected against polarity reversal by isolating transformer to EN 60742 Permissible residual ripple The lower and upper supply voltage limits must not be infringed. Cable length min. 16.8 V
Data typ. 24 V max. 28.8
500 mV
50 m
Cable cross-section
2.5 mm 2
Permissible line impedance
2.5 Ohm
Response time (adjustable) Double speed Formula for scan rate (n = 2 to 16) Exception: PLS101-316 with LSI in vehicle protection; here the response time is 270 ms, non-adjustable Power-up time On power-on
190 ms
110 ms + ( n x 40 ms )
9 sec.
Power consumption without PLS and no load
15 W with 1 PLS and max. load
63 W with 2 PLS and max. load
80 W with 3 PLS and max. load
97 W with 4 PLS and max. load
114 W
PLS connection
152
See PLS technical data. Connect only PLS units of same type.
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved