Page 153

LSI

GB

Specifications

Data typ.

min. RES A, RES B (Reset/Restart input) Quantity Input impedance at HIGH max.

One input per OSSD pair 3.8 k Ohm

Voltage for HIGH

15 V

28.8 V

Voltage for LOW

0V

1V

15 mA

32 mA

3.5 mA

9 mA

160 ms 240 ms 160 ms

5s

Current consumption Start pulse current (where t = 100 us) Static input current Time response of Restart button Low level before actuation High level during actuation Low level after actuation Cable length Cable cross-section Permissible line impedance EDM input (external contact monitoring) Quantity Input impedance at HIGH Voltage for HIGH Voltage for LOW Current consumption Start pulse current (where t = 100 us) Static input current

50 m 2.5 mm 2 2.5 Ohm

One input per OSSD pair 3.8 k Ohm 15 V 28.8 V 0V 1V 15 mA

32 mA

3.5 mA

9 mA

8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved

153

Page 154

GB

LSI

Specifications min. Time response of EDM input High level after OSSD activation Low level on OSSD deactivation Cyclic monitoring of the rest and operating positions Cable length Cable cross-section Permissible line impedance Inputs A, B (2-channel: A1, A2/B1, B2 antivalent), static binary Input impedance at HIGH Voltage for HIGH Voltage for LOW Current consumption Start pulse current (where t = 100 us) Static input current Port inconsistency Time window for valid switchover (at double speed scan rate) Cable length Cable cross-section Permissible line impedance Inputs C, D (2-channel: C1, C2/D1, D2 antivalent), static binary Input impedance at HIGH Voltage for HIGH Voltage for LOW

154

Data typ.

max. 200 ms 200 ms

5s 50 m 2.5 mm 2 2.5 Ohm

3.8 k Ohm 15 V 0V

28.8 V 1V

15 mA

32 mA

3.5 mA

9 mA 80 ms

50 m 2.5 mm 2 2.5 Ohm

2.6 kOhm 15 V 0V

28.8 V 1V

8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved

Page 155

LSI

GB

Specifications min. Current consumption Start pulse current (where t = 0.5 us) Static input current Port inconsistency Time window for valid switchover (at double speed scan rate) Cable length Cable cross-section Permissible line impedance Inputs C, D (only for incremental encoder 0°/90°), dynamic Input impedance at HIGH Voltage for HIGH Voltage for LOW Current consumption Start pulse current (where t = 0.5 us) Static input current Duty factor g (Ti/T) Input frequency Min. number of pulses per cm Evaluatable speed range

Data typ.

max.

15 mA

32 mA

5 mA

13 mA 80 ms 50 m 2.5 mm 2 2.5 Ohm

2.6 kOhm 15 V 0V

28.8 V 1V

15 mA

32 mA

5 mA

13 mA 0.5 100 kHz

50 ±10 cm/s

Tolerance time for differing direction information Speed tolerance overrange with incremental encoders in same direction Cable length Cable cross-section Permissible line impedance

8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved

±2.000 cm/s 400ms 20 s

50 m 2.5 mm 2 2.5 Ohm

155

Page 156

GB

LSI

Specifications

Data typ.

min. Warning field output A/B (PNP), HIGH active Quantity Switching voltage High-active at 50 mA Switching voltage High-active at 100 mA Switching current (referred to EXT_GND) Current limitation ( t= 5ms, 25 deg. Celsius) Pure load inductance Switching sequence Response time ( n = 2 to 16 ; n = scan rate) Cable length Cable cross-section Permissible line impedance Error output (PNP), HIGH active Quantity Switching voltage High-active at 50 mA Switching voltage High-active at 100 mA Switching current (referred to EXT_GND) Current limitation ( t= 5ms, 25 deg. Celsius) Pure load inductance Switching sequence Cable length Cable cross-section Permissible line impedance

156 max.

One output per OSSD pair Uv – 1 V Uv Uv –0.5 V

Uv 100 mA

600 mA

920 mA

2H 1 6 /s 150ms + ( n x 40 ms ) 50 m 2.5 mm 2 2.5 Ohm

One output Uv -1 V

Uv

Uv –0.5 V

Uv 100 mA

600 mA

920 mA 2H » 4 1/ s 50 m 2.5 mm 2 2.5 Ohm

8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved

Page 157

LSI

GB

Specifications min.

Data typ.

max. Safety outputs (OSSD A, OSSD B), dynamic, High-active Quantity Two 2-channel outputs Switching voltage High-active Uv -3,4 V Uv (Ueff) Voltage for LOW 0V 2.5 V Switching current (referred to 2 mA 250 mA EXT_GND) Short-circuit protected by monitoring of outputs In case of error: Leakage current, 1,1 mA break in GND cable. The downstream control element must recognise this status as Low. Pure load capacity 100 nF Pure load inductance 2H Switching sequence (without 6 1/ s switchover and without simultaneous monitoring) Response time at double speed 190 ms Cable length 50 m Cable cross-section 2.5 mm 2 Permissible line impedance 2.5 Ohm Test pulse data (OSSD_Test) Test pulse width 100 us Test frequency Once per scan Test pulse data (Test_Ub) Test pulse width 100 us Test frequency Twice per scan Safety category Single error fail-safe DIN V 19250 Requirement class 4 EN 954-1 Category 3 IEC/EN 61496-1 Type 3

8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved

157

Page 158

GB

LSI

Specifications min. General specifications Enclosure rating Installation in switch cabinet with min. IP 54 specified. Protection class

Warning field output

Error output Reset/Restart input

158 max. IP 20

3 Safety-low voltage F to DIN 40040 IEC 60068, part 2-6 10 ... 55 Hz 0.35 mm IEC 60068, part 2-29 10 g / 16 ms IEC / EN 61496-1 type 4 EN 50081-2 DIN 40839-1 and -3 1.25 kg 216 mm x 108 mm x 86 mm

Humidity class Vibrostability Frequency range Amplitude Shock resistance Continuous shock 1000 Interference immunity (EMC) Mass (net) Dimensions (W x H x D) Dimensions excluding terminals and connectors Operating temperature in degrees Celsius Storage temperature in degrees Celsius Protective fields Warning fields Protective field output

Data typ.

0

+50

–25

+70

1 1

8 8 2 independent, monitored semiconductor outputs, 2-channel, PNP High-active, 24 V/250 mA 2 independent semiconductor outputs, PNP High-active, 24 V/100 mA 1 semiconductor output, PNP High-active, 24 V/100 mA 1 input per OSSD pair (at DC 24 V)

8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved

Page 159

LSI Specifications

GB Data typ. max. 1 input per OSSD pair (to DC 24 V) Static binary inputs to DC 24 V min. EDM input (external contact monitoring) Inputs A1, A2, B1, B2, C1, C2, D1, D2 Inputs C, D Switchover of monitoring cases (use of inputs A - D)

Interface (PC) Only for temporary configuration and diagnostic purposes Transmission rate RS 232 RS 422 Cable length RS 232 RS 422 Interface (LSI - PLS) Use of a low-capacity twisted pair data cable of type Li2YCY (TP) with a min. cross-section of 2 x 2 x 0.25 mm 2 Transmission rate RS 422 Cable length RS 422 Cable cross-section RS 422

Dynamic inputs to DC 24 V 4 static binary input pairs (x1 and x2 antivalent) A1, A2, B1, B2, C1, C2, D1, D2 or 2 dynamic incremental encoder inputs (C, D) and 2 static binary input pairs (x1 and x2 antivalent) A1, A2, B1, B2

9600, 19200, 38400 Baud 9600, 19200, 38400 Baud 15 m 100 m

500kB 30 m 0.25 mm 2

8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved

159

Page 160

GB

LSI

11. Appendix: Key to diagrams The diagrams can be found at the end of this manual. Figure 1: Dimensional drawing All dimensions are shown in mm. H Bracket for wall mounting (accessory) Figure 2: Pin assignment X1 Power supply X2, X3 PLS power supply X4, X7 Communication line to PLS X8 Connection to PC X14, X15 Connection of current outputs for OSSD, Warning field (WF) and ERROR X13 Connection of Reset/Restart and external contact monitoring (EDM) inputs X11, X12 Connection of static inputs A, B, C and D X9, X10 Connection of dynamic inputs C and D Figure 3: Pin assignment, Sub D 9-pin A LSI à PC: PC interface RS 232/422 “X8” (jumper 7-8 in case of connection to a PC with RS 422 interface) B PLS à LSI: Data interface RS 422 on PLS (jumper 7-8 to switch to RS 422) C LSI à PLS: Data interface RS 422 “X4...X7“ on LSI (connect shield to strain relief) D LSI à INC: Signal interface “X9, X10“ to incremental encoders (connect shield to strain relief)

160

8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved