The text of a manual · part 18 of 37
Laser Scanner Interface LSI 101 Operating Instructions: English, pages 153 to 160
Pages 153 to 160 of 322, from Laser Scanner Interface LSI 101 Operating Instructions
The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Sick LSI-101
Page 153
LSI
GB
Specifications
Data typ.
min. RES A, RES B (Reset/Restart input) Quantity Input impedance at HIGH max.
One input per OSSD pair 3.8 k Ohm
Voltage for HIGH
15 V
28.8 V
Voltage for LOW
0V
1V
15 mA
32 mA
3.5 mA
9 mA
160 ms 240 ms 160 ms
5s
Current consumption Start pulse current (where t = 100 us) Static input current Time response of Restart button Low level before actuation High level during actuation Low level after actuation Cable length Cable cross-section Permissible line impedance EDM input (external contact monitoring) Quantity Input impedance at HIGH Voltage for HIGH Voltage for LOW Current consumption Start pulse current (where t = 100 us) Static input current
50 m 2.5 mm 2 2.5 Ohm
One input per OSSD pair 3.8 k Ohm 15 V 28.8 V 0V 1V 15 mA
32 mA
3.5 mA
9 mA
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
153
Page 154
GB
LSI
Specifications min. Time response of EDM input High level after OSSD activation Low level on OSSD deactivation Cyclic monitoring of the rest and operating positions Cable length Cable cross-section Permissible line impedance Inputs A, B (2-channel: A1, A2/B1, B2 antivalent), static binary Input impedance at HIGH Voltage for HIGH Voltage for LOW Current consumption Start pulse current (where t = 100 us) Static input current Port inconsistency Time window for valid switchover (at double speed scan rate) Cable length Cable cross-section Permissible line impedance Inputs C, D (2-channel: C1, C2/D1, D2 antivalent), static binary Input impedance at HIGH Voltage for HIGH Voltage for LOW
154
Data typ.
max. 200 ms 200 ms
5s 50 m 2.5 mm 2 2.5 Ohm
3.8 k Ohm 15 V 0V
28.8 V 1V
15 mA
32 mA
3.5 mA
9 mA 80 ms
50 m 2.5 mm 2 2.5 Ohm
2.6 kOhm 15 V 0V
28.8 V 1V
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
Page 155
LSI
GB
Specifications min. Current consumption Start pulse current (where t = 0.5 us) Static input current Port inconsistency Time window for valid switchover (at double speed scan rate) Cable length Cable cross-section Permissible line impedance Inputs C, D (only for incremental encoder 0°/90°), dynamic Input impedance at HIGH Voltage for HIGH Voltage for LOW Current consumption Start pulse current (where t = 0.5 us) Static input current Duty factor g (Ti/T) Input frequency Min. number of pulses per cm Evaluatable speed range
Data typ.
max.
15 mA
32 mA
5 mA
13 mA 80 ms 50 m 2.5 mm 2 2.5 Ohm
2.6 kOhm 15 V 0V
28.8 V 1V
15 mA
32 mA
5 mA
13 mA 0.5 100 kHz
50 ±10 cm/s
Tolerance time for differing direction information Speed tolerance overrange with incremental encoders in same direction Cable length Cable cross-section Permissible line impedance
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
±2.000 cm/s 400ms 20 s
50 m 2.5 mm 2 2.5 Ohm
155
Page 156
GB
LSI
Specifications
Data typ.
min. Warning field output A/B (PNP), HIGH active Quantity Switching voltage High-active at 50 mA Switching voltage High-active at 100 mA Switching current (referred to EXT_GND) Current limitation ( t= 5ms, 25 deg. Celsius) Pure load inductance Switching sequence Response time ( n = 2 to 16 ; n = scan rate) Cable length Cable cross-section Permissible line impedance Error output (PNP), HIGH active Quantity Switching voltage High-active at 50 mA Switching voltage High-active at 100 mA Switching current (referred to EXT_GND) Current limitation ( t= 5ms, 25 deg. Celsius) Pure load inductance Switching sequence Cable length Cable cross-section Permissible line impedance
156 max.
One output per OSSD pair Uv – 1 V Uv Uv –0.5 V
Uv 100 mA
600 mA
920 mA
2H 1 6 /s 150ms + ( n x 40 ms ) 50 m 2.5 mm 2 2.5 Ohm
One output Uv -1 V
Uv
Uv –0.5 V
Uv 100 mA
600 mA
920 mA 2H » 4 1/ s 50 m 2.5 mm 2 2.5 Ohm
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
Page 157
LSI
GB
Specifications min.
Data typ.
max. Safety outputs (OSSD A, OSSD B), dynamic, High-active Quantity Two 2-channel outputs Switching voltage High-active Uv -3,4 V Uv (Ueff) Voltage for LOW 0V 2.5 V Switching current (referred to 2 mA 250 mA EXT_GND) Short-circuit protected by monitoring of outputs In case of error: Leakage current, 1,1 mA break in GND cable. The downstream control element must recognise this status as Low. Pure load capacity 100 nF Pure load inductance 2H Switching sequence (without 6 1/ s switchover and without simultaneous monitoring) Response time at double speed 190 ms Cable length 50 m Cable cross-section 2.5 mm 2 Permissible line impedance 2.5 Ohm Test pulse data (OSSD_Test) Test pulse width 100 us Test frequency Once per scan Test pulse data (Test_Ub) Test pulse width 100 us Test frequency Twice per scan Safety category Single error fail-safe DIN V 19250 Requirement class 4 EN 954-1 Category 3 IEC/EN 61496-1 Type 3
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
157
Page 158
GB
LSI
Specifications min. General specifications Enclosure rating Installation in switch cabinet with min. IP 54 specified. Protection class
Warning field output
Error output Reset/Restart input
158 max. IP 20
3 Safety-low voltage F to DIN 40040 IEC 60068, part 2-6 10 ... 55 Hz 0.35 mm IEC 60068, part 2-29 10 g / 16 ms IEC / EN 61496-1 type 4 EN 50081-2 DIN 40839-1 and -3 1.25 kg 216 mm x 108 mm x 86 mm
Humidity class Vibrostability Frequency range Amplitude Shock resistance Continuous shock 1000 Interference immunity (EMC) Mass (net) Dimensions (W x H x D) Dimensions excluding terminals and connectors Operating temperature in degrees Celsius Storage temperature in degrees Celsius Protective fields Warning fields Protective field output
Data typ.
0
+50
–25
+70
1 1
8 8 2 independent, monitored semiconductor outputs, 2-channel, PNP High-active, 24 V/250 mA 2 independent semiconductor outputs, PNP High-active, 24 V/100 mA 1 semiconductor output, PNP High-active, 24 V/100 mA 1 input per OSSD pair (at DC 24 V)
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
Page 159
LSI Specifications
GB Data typ. max. 1 input per OSSD pair (to DC 24 V) Static binary inputs to DC 24 V min. EDM input (external contact monitoring) Inputs A1, A2, B1, B2, C1, C2, D1, D2 Inputs C, D Switchover of monitoring cases (use of inputs A - D)
Interface (PC) Only for temporary configuration and diagnostic purposes Transmission rate RS 232 RS 422 Cable length RS 232 RS 422 Interface (LSI - PLS) Use of a low-capacity twisted pair data cable of type Li2YCY (TP) with a min. cross-section of 2 x 2 x 0.25 mm 2 Transmission rate RS 422 Cable length RS 422 Cable cross-section RS 422
Dynamic inputs to DC 24 V 4 static binary input pairs (x1 and x2 antivalent) A1, A2, B1, B2, C1, C2, D1, D2 or 2 dynamic incremental encoder inputs (C, D) and 2 static binary input pairs (x1 and x2 antivalent) A1, A2, B1, B2
9600, 19200, 38400 Baud 9600, 19200, 38400 Baud 15 m 100 m
500kB 30 m 0.25 mm 2
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved
159
Page 160
GB
LSI
11. Appendix: Key to diagrams The diagrams can be found at the end of this manual. Figure 1: Dimensional drawing All dimensions are shown in mm. H Bracket for wall mounting (accessory) Figure 2: Pin assignment X1 Power supply X2, X3 PLS power supply X4, X7 Communication line to PLS X8 Connection to PC X14, X15 Connection of current outputs for OSSD, Warning field (WF) and ERROR X13 Connection of Reset/Restart and external contact monitoring (EDM) inputs X11, X12 Connection of static inputs A, B, C and D X9, X10 Connection of dynamic inputs C and D Figure 3: Pin assignment, Sub D 9-pin A LSI à PC: PC interface RS 232/422 “X8” (jumper 7-8 in case of connection to a PC with RS 422 interface) B PLS à LSI: Data interface RS 422 on PLS (jumper 7-8 to switch to RS 422) C LSI à PLS: Data interface RS 422 “X4...X7“ on LSI (connect shield to strain relief) D LSI à INC: Signal interface “X9, X10“ to incremental encoders (connect shield to strain relief)
160
8 008 308/M848/06-05-02 Operating Instructions · LSI © SICK AG · Industrial Safety Systems · Germany · All rights reserved