Page 11
6
Supply package
You should receive: – the LSI – a connection set as per your order (see below) (e.g. connection set A: one PLS power plug, one PLS interface connector, one screw-in interface connector to connect the PLS to the LSI) – one DIN rail bracket (mounted) – two wall mounting brackets – the Operating Instructions – this Technical Description – 10 plug-in connectors Note: No user software is supplied with the LSI. The PLS/LSI user software as from version 03.21(16-bit)/03.61 (32-bit) is used to programme a single PLS or an LSI system. It is supplied with the PLS (on a 3.5" floppy disk). Version 03.21 is only shipped on request.
Available connection sets: Order no. Connection set A 1 PLS power plug, 1 PLS interface connector, 1 screw-in interface connector for sensor connection to LSI, without cable
2 019 065
Various cable lengths are available. Connection set B As connection set A, with 3 metre cable
2 019 066
Connection set C As connection set A, with 5 metre cable
2 019 067
Connection set D As connection set A, with 10 metre cable
2 019 068
Connection set E As connection set A, with 15 metre cable
2 019 069
Connection set F As connection set A, with 20 metre cable
2 019 070
Connection set G As connection set A, with 30 metre cable
2 025 902
8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved
11
Page 12
7
Installing the LSI
The LSI is shipped with a DIN rail bracket. A wall bracket is also supplied. By mounting the LSI on the wall bracket you can eliminate unwanted vibration effects. Mounting the LSI on a DIN rail: Mount the LSI as shown in the diagram with a TS 35 standard DIN rail.
min. 75
108 min. 75
•
13
86
LSI with a DIN rail (all dimensions in mm)
Mounting the LSI on a wall:
•
Unscrew the DIN rail bracket.
216
Attach the supplied wall bracket to the LSI as shown in the diagram. 7
• •
Mount the LSI on the wall. Use M 6 size screws.
226
Mounting the LSI on a wall (all dimensions in mm)
12
8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved
Page 13
8
Connecting the LSI
8.1 Wiring up the LSI and PLS Sub-D connector
Note: Also refer to the complete connection diagram in the appendix. Cabling requirements Communication cable from LSI to PLS: The communication cable to the PLS must be a shielded twisted pair data cable (“Twisted pair”). On the LSI end be sure to use the accessory 9-pin metallised Sub D connectors, because they are provided with a special shield. Connect the data cable braid to the strain relief on the LSI end only. The braid is not connected at the PLS end. Pay attention to the pin assignment. Use a low-capacitance twisted pair data cable of type Li2YCY (TP) with a cross-section of at least 2 x 2 x 0.25 mm2. Max. cable length: 30 m
X4
X5
X6
X7
1
2
3
4
SENSOR
SENSOR
SENSOR
SENSOR
PLS
To LSI
1
Power supply cable to PLS: Use a copper cable with a maximum cross-section of 0.5 mm2. Max. cable length: 30 m
• • •
9
Shield open
Connect the LSI “Power Out +” and “Power Out –” terminals to the power supply terminals on the PLS sensors using 4-pin spring terminal strips.
LSI
Connect the LSI communication terminals (e.g. “Sensor 1”) to the PLS interface.
To PLS
1
Connect the braid to the strain relief on the LSI end. The braid on the PLS end is not connected. Pay attention to the pin assignment.
9
Note: The safety outputs (OSSD) of the connected PLS unit(s) must not be used in conjunction with the LSI. Also refer to the complete connection diagram in the appendix.
Connect shield to strain relief
Connecting PLS to LSI
LSI
RXD– RXD+ TXD+ TXD– Housing NC NC NC NC NC
Sensor Pin no.
Pin no.
1 2 3 4
1 2 3 4
5 6 7 8 9
Shield connected on LSI end to strain relief (housing)
5 6 7 8 9
RXD– RXD+ TXD+ TXD– NC NC NC Jumpered NC
Pin assignment of the RS 422 interface connector
8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved
13
Page 14
8.2 Connecting the LSI to the control and the power supply Note: Also refer to the complete connection diagram in the appendix. Cabling requirements Power supply cable to LSI: Use a copper cable with a maximum cross-section of 2.5 mm2. Max. cable length: 50 m Signal cables from and to the LSI: Use a copper cable with a maximum cross-section of 2.5 mm2. Max. cable length: 50 m
Lay all cables and wires such that they are protected against damage. The wires for all connectors must be carried outside the control cabinet in separate sheathed cables. If you are using the LSI to guard danger zones: Make sure the connected control system and all other equipment conforms to the required safety level! If you have not switched monitoring cases for a long time, carry out a function check of the connected input controller. You can carry out the check in a number of ways: – Intentional intrusion in the active protective field after switching monitoring cases (paying attention to simultaneous monitoring cases!) – Check by means of the I/O monitor (see section 9.10) Also refer to the complete connection diagram in the appendix.
Connecting LSI inputs:
•
Connect the inputs (A, B, C, D) of the LSI to the control as shown in the connection diagram. Use 4-pin spring terminal strips (the supplied WAGO crimp tool will help with wiring). Notes: Each input requires two signals which must always be mutually inverted (maximum permitted tolerance: 80 ms with 2-scan evaluation). If you are using incremental encoders, the binary inputs C and D are occupied and so are not available to you.
Mark the connectors to prevent inadvertent swapping. Switching of monitoring cases is initiated by a signal change at inputs A, B, C, D. When this occurs it must be ensured that the protective effect is maintained and the machine/vehicle is always set to a safe condition.
Connecting LSI outputs:
X14
K5 K6 K1 K2
K7 K3 K4
EDM B
X13
RES B
EDM A
OSSD B2
WZ B
OSSD B1
X15
B RES A
A
B OSSD A2
OSSD A1
A ERROR
Connect the outputs to the control as shown in the connection diagram. Use 4-pin spring terminal strips. Note: Each safety output (OSSD) may be connected to only one switching element. If several switching elements are required, suitable contact expansion must be provided. Note that in safety-related controls for K1 to K4 you must use relays or contactor relays with positively guided contacts, incorporating the appropriate precautions (protective circuit).
WZ A
•
INPUT A1
A2
B1
X12
INPUT B2
C1
C2
D1
D2
X11
24 V DC
Connecting LSI inputs and outputs
14
8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved
Page 15
Connecting the LSI to the power supply:
•
Sensors
Connect the power supply connection of the LSI by way of an appropriately rated fuse to the power supply source, e.g. a 24 V DC power supply unit (transformer with safe isolation to EN 60742; see technical data in appendix) Use 3-pin spring terminal strips.
Power supply unit DC 24 V
Si X1
X2
_
+
_
_
+
POWER IN
X3 _
+
_
+
POWER OUT
_
+
POWER OUT
LSI Connecting the LSI to the power supply
Connecting restart buttons as necessary:
X14
EDM B
B RES B
EDM A
OSSD B2
WZ B
Notes: Outside the switch cabinet “RES A” and “RES B” must be routed in separate sheathed cables.
A
B
RES A
Connect the restart buttons (NO contacts) to inputs “RES A” and “RES B”. Use 4-pin spring terminal strips.
OSSD B1
•
INPUT A1
A2
X13
INPUT
B1
C1
B2
X12
C2
D1
D2
X11
When mounting the restart buttons, make sure the button is mounted such that the danger zone is in full view when the button is pressed. 24 V DC
Connecting restart buttons
Connecting an external device monitor as necessary:
Notes: Outside the switch cabinet “EDM A” and “EDM B” must be carried in separate sheathed cables. External device monitoring is activated 200 ms after a switching operation. In the static state the outputs are tested cyclically every 5 seconds.
X15
K1 K2
K3 K4
EDM B
X13 K1
K3
K2
K4
RES B
EDM A
OSSD B1
OSSD B2
WZ B
X14
B RES A
A
B OSSD A2
OSSD A1
A ERROR
Connect the NC contacts of the contactors to inputs “EDM A” and “EDM B” as shown in the diagram. (K1 to K4 are contacts of the elements which directly control the hazardous movement.) Use 4-pin spring terminal strips.
WZ A
•
INPUT A1
A2
B1
B2
X12
24 V DC
Connecting an external device monitor
8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved
15
Page 16
Connecting incremental encoders as necessary:
•
Connect two incremental encoders to “Speed Input C” and “Speed Input D”. Use 9-pin metallised Sub-D connectors.
Notes: If you are using incremental encoders, the binary inputs C and D are occupied and so are not available to you. The incremental encoders must meet the following requirements: – Type: Two-channel rotary encoder with 90° phase offset – Power supply: 24 V DC – Outputs: Push/pull outputs – Protection IP 54 – Shielded cables – Max. pulse frequency: 100 kHz – min. 50 pulses per cm
OR
INPUT C1
C2
D1
SPEED INPUT SPEED INPUT D2
X11
C
D
X10
X9
Must remain open! 1/f
1/f
Incremental encoders Connecting incremental encoders
Outside the switch cabinet the connecting wires of the incremental encoders must be routed in separate sheathed cables. On the LSI end be sure to use the accessory 9-pin metallised Sub D connectors, because they are provided with a special shield.
•
Connect the shield braid to the strain relief as shown in the diagram. Pay attention to the pin assignment.
LSI
To incremental encoder
1
9
Connect shield to strain relief Pin assignment
Note: You will find a number of examples of connection and configuration options for the LSI in section 12.1. Make sure your incremental encoders deliver at least 50 pulses per centimetre travelled by your vehicle (for configuration of incremental encoders see section 9.7 and the calculation example in the appendix).
1 +24 V DC 2 +24 V DC 3 GND 4 GND 5 n.c. 6 IN 0 7 IN 90 8 GND 9 n.c.
Shielding and pin assignment
16
8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved
Page 17
8.3 Connecting the LSI to a PC To configure your LSI system or change settings, you must temporarily connect the PC to the LSI. For this purpose the LSI is fitted with a RS 232/RS 422 interface which enables you to connect quickly and easily between the PC and the LSI.
•
Connect the LSI interface RS 232 (COM port) to a free serial port on the PC. Use a RS 232/RS 422 interface cable (see “Accessories” in the appendix). PC
You can then configure the LSI system. PLS
LSI
Connecting the LSI to a PC
Notes: The LSI’s RS 232 interface is set up for connection to the PC. If required, you can reprogramme it to a RS 422 interface by jumpering pins 7 and 8. The “RS 422” LED on the LSI then lights up as an indicator. The pin assignment of a RS 422 interface is not standardised. Compare the configuration on the connecting cable with the pin configuration on the PC (see diagram) and adapt it as necessary.
LSI
PC Pin no.
Pin no.
NC RXD TXD NC GND
1 2 3 4 5
1 2 3 4 5
NC RXD TXD NC GND
NC NC NC NC
6 7 8 9
6 7 8 9
NC NC NC NC
Shield
Pin assignment of the interface connector in RS 232 mode
LSI
RXD– RXD+ TXD+ TXD– Housing NC NC Jumpered NC
PC Pin no.
Pin no.
1 2 3 4
1 2 3 4
5 6 7 8 9
Shield connected on LSI end to strain relief (housing)
5 6 7 8 9
RXD– RXD+ TXD+ TXD– NC NC NC NC NC NC
Pin assignment of the interface connector in RS 422 mode
8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved
17
Page 18
9
Programming the LSI – User software 9.1 Installing the PLS/LSI user software Note: The PLS/LSI user software as from version 03.21/03.61 is used to programme a single PLS or an LSI system. If you have already installed this user software on your PC for a PLS application you do not need to install any new software for the LSI. You can start programming immediately. If you have an older PLS/LSI user software version installed on your PC and want to continue using it, enter a different program folder for the new PLS/LSI user software version when installing it. System requirements Take note of the relevant hardware requirements of the operating systems listed. – min. 4 MB available memory on the hard disk – Windows 95TM, Windows 98TM or Windows NTTM 4/SP4 (version 03.21 available for WindowsTM 3.11 on request) – min. 80486 processor – min. 4 MB RAM – Colour monitor recommended – Installed graphics printer driver – Correctly set date and time (utilised in configuration protocol) The Install programme guides you through the installation process for your PLS/LSI user software. Simply run the Install programme. To run Install:
• • •
• • •
Boot your PC. Insert the PLS/LSI programme disk in your PC’s floppy disk drive. Under WindowsTM 3.11: Choose File – Run from the FileManager. Windows 95TM, Windows 98TM and Windows NTTM 4/SP4: Choose Run from the Start menu. Select and run “Install.exe”. As necessary, enter the program directory/folder where you want the new PLS/LSI user software to be installed. Follow the on-screen instructions.
When the installation is finished a message box appears telling you that the setup has been completed successfully. The PLS/LSI user software programme has been installed. You can run it any time by clicking on its icon.
18
8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved
Page 19
9.2 Procedure Notes: When the program starts you are automatically logged on as the machine operator. As such, you can poll data but cannot transmit any. To be able to transmit configuration data and monitoring areas to the LSI, you must log on as an “Authorised Client”. How to log on is described in section 9.3. Make sure the LSI and all PLS units are correctly connected, as described in section 8. The status bar at the bottom of the screen contains a colour key for on-screen display of the protective field and warning field. Essential steps In creating a new configuration you are guided by the PLS/LSI user software. It guides you automatically through the following steps:
•
•
•
•
• •
Configure hardware: You log the sensors on and select whether you are using the LSI for area protection or for protection on a vehicle. You also define the inputs and outputs and the restart behavior of the outputs. Define monitoring areas: You define the areas to be monitored by the LSI. If you wish, you can also determine the shape and size of the protective fields and warning fields here. You can define up to eight monitoring areas. Define monitoring cases For each monitoring case (max. 15) you link a sensor to a monitoring area and define the input conditions under which the monitoring case is to be activated. Here you also define which output is switched when there is an intrusion into the protective field. You can also define a specific order of switching between the monitoring cases. Send a configuration to the LSI: You now transmit all the configuration settings you have made to the LSI. You must be logged on as an “Authorised Client” to be able to do this. Edit monitoring areas: Here, if you wish, you have the chance to alter the shape and size of the protective fields and warning fields. Send monitoring areas to LSI: Finally you transmit the protective fields and warning fields to the LSI. For this, too, you must be logged on as an “Authorised Client”.
When you have completed these steps the LSI system is ready for operation. Note: Change the logon password, to protect your LSI system against manipulation (see section 9.13). Log your configuration data stored in the LSI, and back up the configuration on the hard disk or on a floppy (see section 9.12).
Other options In addition to the essential steps, you can use a number of other options when configuring your LSI system. – Edit fields: To edit the protective and warnings fields the PLS/LSI user software provides you with a number of useful editing functions. – Teach-in and check protective field: In the teach-in process the active sensor scans the defined space contour, and the LSI generates a protective field from the scan. You can influence the physical extent of the protective field by marking out its contour with a target board, for example. You have to check learned protective fields. You can also edit a learned protective field subsequently, just like any other segmented field. (This function is not available for the LSI used with PLS 101-316 .) – Adapt protective fields to speed: If you are using the LSI on a vehicle, you can switch between protective fields of different size and shape depending on the speed of the vehicle. In this way you can adapt the monitoring area flexibly to the surroundings and speed of the vehicle. For this, you must connect incremental encoders to the LSI. – Simulate monitoring cases: You can check the monitoring case settings by simulating the input conditions on PC . In this way you can check whether the sensors and fields are correctly assigned in every monitoring case. – Monitor protective fields: You can monitor the protective fields and warning fields in operation using a connected PC. You can also store the defined space contours of the sensors as a check. – Monitor inputs and outputs: You can monitor and log the switching states of the inputs and outputs of the LSI with the I/O monitor. You can save the retrieved data to an ASCII file for further evaluation. – Check settings: You can view, check and print all configuration settings in a page view. – Receive and store configuration: You can receive and print the configuration data stored in the LSI. You can save any configuration to the hard disk or to a floppy. – Change password: To protect your LSI against manipulation, you should change the logon password. – Change screen view: You can zoom, unzoom or move the screen view, for example. – Interrogate fault memory (system diagnosis): For troubleshooting purposes you can interrogate the fault memory of the LSI and the connected sensors.
8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved
19
Page 20
9.3 Getting started: Initial configuration The LSI is shipped with certain pre-configured settings. This section describes how you can adapt those settings to your application.
• •
Switch on your LSI system (it takes a few seconds to start up). Start the PLS/LSI user software.
The following dialogue box appears:
•
Click on “Yes”.
The PC receives the pre-configured settings and displays them on-screen. Note: To start up the system the desired configuration must always be transmitted from the PC to the LSI.
The following dialogue box appears: To be able to transmit configuration data and monitoring areas to the LSI subsequently, you must be logged on as an “Authorised Client”.
• •
Choose “Authorised Client” from the category list. Enter the password “SICK_PLS” and click on “Logon”.
You are now logged on as an “Authorised Client” (see status bar at bottom of screen). Note: Always log off when leaving your workstation! This will prevent unauthorised persons from manipulating your LSI system.
20