Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 1 of 9

Laser Scanner Interface LSI 101 Technical Description, pages 1 to 10

Pages 1 to 10 of 82

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Sick LSI-101

Page 1

8 008 310/M848/06-05-02 • TW/SM • Printed in Germany (08.03) • Subject to change without prior notice • en_13.02_TB

Contact: A u s t r a li a Phone +61 3 9497 4100 1 800 33 48 02 – tollfree Fax +61 3 9497 1187 A u s t r i a Phone +43 (0)22 36 62 28 8-0 Fax +43 (0)22 36 62 28 85 Be l g iu m / Lu x em bo u r g Phone +32 (0)2 466 55 66 Fax +32 (0)2 463 31 04 Br a z il Phone +55 11 5561 2683 Fax +55 11 5535 4153 Ch i n a Phone +85 2-2763 6966 Fax +85 2-2763 6311 Cz e c h Re p u b l ic Phone +420 2 57 91 18 50 Fax +420 2 57 81 0559 De n m a r k Phone +45 45 82 64 00 Fax +45 45 82 64 01 Fi n l a nd Phone +358 (0)9 25 15 800 Fax +358 (0)9 25 15 8055 Fr a n c e Phone +33 1 64 62 35 00 Fax +33 1 64 62 35 77 G e rm an y Phone +49 (0)2 11 53 01-0 Fax +49 (0)2 11 53 01-100 G r ea t B r i ta in Phone +44 (0)1727 831121 Fax +44 (0)1727 856767 I t a l y Phone +39 02 92 14 20 62 Fax +39 02 92 14 20 67 Ja p a n Phone +81 (0)3 3358 1341 Fax +81 (0)3 3358 9048 Ko r e a Phone +82-2-786 6321/4 Fax +82-2-786 6325 N e t h er l a n d s Phone +31 (0)30 229 25 44 Fax +31 (0)30 229 39 94 N o r wa y Phone +47 67 81 50 00 Fax +47 67 81 50 01 Po l a n d Phone +48 22 837 40 50 Fax +48 22 837 43 88 Si n g a po r e Phone +65 6744 3732 Fax +65 6841 7747 Sp a i n Phone +34 93 480 31 00 Fax +34 93 473 44 69 Sw e d en Phone +46 8 680 64 50 Fax +46-8 710 18 75 Sw i tz er l a n d Phone +41 41 619 29 39 Fax +41 41 619 29 21 Ta i w a n Phone +886 2 2365-6292 Fax +886 2 2368-7397 US A / C a na d a / M e x i co Phone +1(952) 941-6780 1-800-325-7425 – tollfree Fax +1(952) 941-9287

Representatives and agencies in all major industrial nations.

SICK AG • Industrial Safety Systems • P.O. Box 310 • 79177 Waldkirch • Germany Phone 49 7681 202-0 • Fax 49 7681 202-35 18 • www.sick.com

Laser Scanner Interface LSI 101

Page 2

This document is protected by the law of copyright, whereby all rights established therein remain with the company SICK AG. Reproduction of this document or parts of this document is only permissible within the limits of the legal determination of Copyright Law. Alteration or abridgement of the document is not permitted without the explicit written approval of the company SICK AG.

2

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

Page 3

Contents 0 General safety advice and protective measures ...................... 4

9.16 Deconfiguring a sensor .......................................................... 57

1 Approvals and certificates ................................................................... 5

10 Tests .......................................................................................................... 58 10.1 Checking the LSI ...................................................................... 58 10.2 Checklist ...................................................................................... 59

2 Information for correct use ................................................................. 6 3 How the LSI functions ........................................................................... 7 4 Application of the LSI ............................................................................ 8 Area protection ............................................................................. 8 Vehicle protection ........................................................................ 8 5 Planning the LSI system ....................................................................... 9 5.1 General planning information ................................................ 9 5.2 Mobile: For on-board vehicle use ...................................... 10 6 Supply package ..................................................................................... 11 7 Installing the LSI .................................................................................... 12 8 Connecting the LSI ............................................................................... 13 8.1 Wiring up the LSI and PLS ..................................................... 13 8.2 Connecting the LSI to the control and the power supply ...................................................................... 14 8.3 Connecting the LSI to a PC ................................................... 17 9 Programming the LSI – User software ......................................... 18 9.1 Installing the PLS/LSI user software ................................ 18 System requirements .............................................................. 18 9.2 Procedure ..................................................................................... 19 Essential steps ........................................................................... 19 Other options .............................................................................. 19 9.3 Getting started: Initial configuration ................................ 20 Configuring the hardware ....................................................... 21 Defining monitoring areas ..................................................... 23 Defining monitoring cases .................................................... 24 Sending a configuration to the LSI .................................... 26 Editing a monitoring area ....................................................... 27 Sending a monitoring area to the LSI ............................... 30 9.4 Expanding the configuration ................................................ 31 Logging on additional sensors ............................................. 31 Defining additional monitoring areas ................................ 32 Defining additional monitoring cases ............................... 32 Changing inputs and outputs ............................................... 34 Changing address .................................................................... 35 Changing application variant ................................................ 35 Changing the restart response ........................................... 36 Configuring incremental encoders ..................................... 36 9.5 Editing/dimensioning fields .................................................. 37 Converting fields ........................................................................ 37 Changing the scale of a segmented field ....................... 38 Copying and pasting fields .................................................... 38 Saving individual fields ........................................................... 38 Fixing co-ordinates ................................................................... 39 9.6 Teaching-in a protective field ............................................. 40 9.7 Adapting protective fields to speed ................................. 42 9.8 Simulating monitoring cases ............................................... 46 9.9 Monitoring protective fields .................................................. 47 Saving a defined space contour ......................................... 47 9.10 Monitoring inputs and outputs ........................................... 48 9.11 Checking settings .................................................................... 49 9.12 Receiving and storing a configuration .................................................. 50 9.13 Changing password ................................................................. 51 9.14 Changing screen view ............................................................ 52 9.15 Interrogating the fault memory (system diagnosis) .................................................................. 54 Initial fault diagnosis ................................................................ 54 Interrogating the fault memory of a sensor ................... 55 Reading the permanent fault memory ............................. 56

11 Care and maintenance ...................................................................... 60 11.1 LEDs on the LSI ........................................................................ 60 11.2 LSI fault table .............................................................................. 61 11.3 SICK Service / Hotline ............................................................ 61 12 Appendix .................................................................................................. 65 12.1 Application examples ............................................................. 65 Examples of area protection ................................................ 65 Examples of on-board vehicle use ..................................... 67 12.2 Start-up testing and restarting ............................................ 70 Performing start-up testing .................................................... 70 Restart after intrusion into the protective field .............. 71 12.3 Technical data ............................................................................ 72 12.4 Accessories ................................................................................. 78 For installation ............................................................................. 78 For connection to the control and the PLS ..................... 78 Power supply units .................................................................... 78 Interface cables ......................................................................... 78 User documentation ................................................................. 78 12.5 Standards and regulations .................................................... 78 12.6 Connection diagram ................................................................ 79 12.7 Dimensional drawing .............................................................. 80 13 Glossary .................................................................................................... 81

This Technical Description contains the information you will need for planning, project design and set-up of the LSI. It describes the mechanical and electrical installation and programming of the LSI. The description covers the following LSI types: – LSI 101-11X (certified for personal protection to IEC/EN 61496-1) The last digit in the type designation (X: 1 to 4) represents the maximum number of connectable sensors. Refer also to the Technical Description for the PLS laser scanner. It contains additional information necessary for planning and installation of the LSI system. As well as the Technical Description you should also have received a set of Operating Instructions, providing you with the key information you will need for day-to-day use of the LSI. Keep the Technical Description and the Operating Instructions in a safe place where they can be accessed at any time. The information contained in this document is subject to change without prior notice.

Essential reading: General safety advice: ........................... Section 0 Important information: ........................... Section 2 Supply package, Installing and connecting the LSI: ................................. Sections 6 to 8 Getting started with the user software: ...................................................... Sections 9.1 to 9.3 Tests: ............................................................. Section 10 Technical data: .......................................... Section 12.3

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

3

Page 4

0

General safety advice and protective measures

Safety regulations and advice 1. The use and installation of the electro-sensitive protective equipment (ESPE), as well as the commissioning process and routine checks, are subject to national and international legal regulations, in particular

• • • •

Machinery Safety Regulations derived from the Machinery Directive 98/37 EC , Work Equipment Regulations derived from the Provision and Use of Work Equipment Directive 89/655 EEC, Any applicable safety regulations and accident prevention regulations and safety guidelines.

The manufacturers and operators of the machinery on which our safety devices are used are solely responsible for ensuring all applicable safety guidelines and regulations from the relevant authorities are observed and complied with. 2. In addition, our recommendations, in particular instructions for testing (see Tests) set out in this Technical Description and in the Operating Instructions (including instructions relating to use, mounting, installation and integration into the machine control system) – must be followed. 3. The tests must be performed by qualified experts or by specially authorised and instructed personnel and must be documented in such a way as to be able to be viewed and understood at any time. 4. Our Operating Instructions must be made available to the employee (operator) of the machine on which our safety device is used. The employee must be instructed by qualified experts. 5. The appendix to this brochure includes a checklist for testing by the manufacturer and equipment supplier and user.

4

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

Page 5

1

Approvals and certificates

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

5

Page 6

2

Information for correct use

The LSI protects personnel and property. It is designed for monitoring of danger zones in enclosed areas in conjunction with one or more PLS laser scanners. Refer also to the instructions regarding intended use. SICK accepts no liability for loss or damage resulting from failure to use the LSI in accordance with its intended purpose.

• • • • • •

•

•

•

• •

6

Pay attention to the information given in the Technical Description to the PLS laser scanner. It contains important information on safe operation of the LSI system.

•

•

•

Install the LSI in a dry location and protect the unit against dirt and damage (IP 54 cabinet). The wires for all connectors must be carried outside the control cabinet in separate sheathed cables. Lay all cables and wires such that they are protected against damage. Avoid strong electrical fields such as from welding cables and induction cables in the immediate vicinity, or from mobile phones being operated close by.

•

To programme the monitoring areas and cases, refer to the description of the PLS/LSI user software in section 9. It describes how to connect the LSI to a PC and operate it with the user software. Note that special parameters are transmitted to a sensor programmed by the LSI. Before it can be disconnected from the LSI and re-used as a stand-alone unit, you will need to deconfigure it using the SICK diagnosis function. If you are using the LSI for vehicle protection, note that it can only be used on vehicles with electric motors. When operating the LSI on materials handling equipment in narrow aisles, be sure to refer to the Technical Description of the corresponding PLS. If you are using the LSI with PLS type 101-316, note that the response time of the LSI is fixed at 270 ms. At the end of its service life, dispose of the LSI in an appropriate, environmentally compatible manner.

Make sure the connected control system and all other equipment conforms to the required safety level. Make sure the control guarantees prompt switching between monitoring cases. Remember that there may already be someone in the protective field when the switch is made. Safe protection can only be guaranteed by prompt switching (that is, before the danger to the person arises at the location concerned). Make sure the input circuit configuration is adequate to the expected ambient conditions, in order to prevent the system from being influenced and resultant errors in monitoring case switching. Make sure the response time of the LSI system is adequate in all monitoring cases to protect the danger zone. (The response time of the LSI depends on the scan rate, and is set in the PLS/LSI user software.) Make sure any obstacles in the monitoring area do not impede or shadow the fields of view of the connected PLS units. If areas of shadowing are unavoidable, check whether they present a risk. Take additional precautions as necessary. Keep the monitoring areas free of smoke, mist, steam and other air pollution. The functioning of the LSI system may otherwise be impaired, and error shutdowns may occur. In installation and use of the LSI comply with the applicable local standards and regulations. A summary listing of the key regulations is presented in the appendix.

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

Page 7

3

How the LSI functions

Operating principle The SICK LSI (Laser Scanner Interface) is an electronic component with which you can interconnect one or more PLS laser scanners and create a system which can be flexibly controlled according to application. This means the LSI system is capable of monitoring complex danger zones on a machine or vehicle. Sensors, monitoring areas and monitoring cases The LSI receives specific input signals from the control, such as input A = low, input B = high. In the LSI the signals activate one of the monitoring cases configured by you using the PLS/LSI user software. The definition of each individual monitoring case determines which monitoring area (consisting of a protective field and a warning field) is to be monitored by the specified connected sensor.

The active sensor, e.g. sensor 1, transmits the space contour it “sees” to the LSI. The LSI compares the data received from the sensor with the contour of the defined monitoring area. As soon as the LSI detects an object in the monitoring area, it shuts off the output configured for the case at hand. In the example there is an object in protective field 3, and the LSI shuts off the defined output OSSD A. This output signal is sent to the control, where it triggers a response, such as an emergency stop. With the aid of the monitoring cases the LSI system can respond flexibly to different input signals and monitor different areas on the sensors depending on the requirements of the situation. Up to two sensors may be active at any one time under the same input conditions (simultaneous monitoring cases).

Evaluation of a monitoring case in the LSI (simplified scheme)

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

7

Page 8

4

Applications of the LSI

This section provides an overview of the key areas of application of the LSI. Area protection On machines involving hazardous movement, the LSI in conjunction with one or more PLS units ensures that the machine (or just its hazardous movement) is stopped as soon as anyone enters the danger zone. This is achieved by means of flexibly definable monitoring areas, each comprising a protective field (PF) and a warning field (WF), which are assigned to the connected sensors for monitoring. The LSI is able to guard the interiors of large machines in the same way. You can define different monitoring cases to adapt the active protective fields to the situation on the machine and to monitor changing danger zones – such as in different production phases of the machine – specific to situation.

Vehicle protection

PF1 WF 1

PF2 WF 2

Machining centre with varying loading positions. Switch signal is initiated by “safe PLC”.

You can use the LSI on vehicles (such as on automated guided vehicles – AGVs, forklifts or shunting trucks), in order to guard a vehicle’s route through a factory hall for example. With its connected sensors, the LSI then ensures the vehicle reduces its speed and ultimately stops if a person or other obstacle is in its way. You can guard manually controlled vehicles and automated guided vehicles (AGVs). Several monitoring cases which you define yourself can be used to monitor different danger zones in different ways, such as when the vehicle is moving forwards or reversing. You can also record the speed of the vehicle by means of incremental encoders, and thereby adapt monitoring areas of different sizes dynamically related to the vehicle speed.

nsor e se tiv inac tion r enso direc es activ

Automated guided vehicle with direction detector and speedsensitive protective field switching

8

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

Page 9

5

Planning the LSI system

5.1 General planning information Sensors: You can connect up to four sensors to the LSI. All connected sensors must be of the same type (e.g. four x PLS 101-312). If you use the system for safety applications, be sure to use safety sensors. Safety sensors are currently types PLS 1XX-3XX, or any types expressly approved as such in the Technical Description. Monitoring areas: You can define up to eight monitoring areas. Each monitoring area consists of a protective field and a warning field. With regard to defining the size of the monitoring areas, refer to the Technical Description of the PLS. It provides examples of dimensioning for static and dynamic applications. For the PLS system with LSI the minimum response time is 190 ms. (Exception: If you are using the LSI together with PLS type 101-316 for vehicle protection, note that the response time of the LSI is then fixed at 270 ms.) Monitoring cases: To view the monitoring areas on the connected sensors, you can set up to 15 monitoring cases. A maximum of two monitoring cases may be active at any one time (simultaneous monitoring cases). Safety and signalling outputs: The LSI has two independent safety output pairs OSSD (output load per OSSD channel max. 250 mA £ 100 nF; reset/restart effective from 0.2 to 5 seconds). If necessary, you can run external device monitoring (EDM) at each of the safety outputs (permitted tolerance max. 200 ms). For the output associated with the warning field and device status, the load is max. 100 mA. Inputs: The LSI has the following inputs: – Four binary inputs (A to D) (2-channel, antivalent) – Two incremental encoder inputs (alternatively to inputs C and D) – Two reset/restart inputs – Two EDM inputs (external device monitoring)

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved

9

Page 10

5.2 Mobile: For on-board vehicle use With the aid of incremental encoders you can adapt the size of the monitored area to the speed of the vehicle. Note: The two incremental encoders must be installed such that one continues working safely and without error if the other one fails. To this end, mechanical and electrical design measures must be implemented to counter a failure of the incremental encoders. Also ensure that no factors influencing the system (e.g. temperature, shaft breakage, slip) are able to influence the speed recording capability of both incremental encoders simultaneously.

For mobile installations you are recommended to affix an adhesive label or a printout of the configuration on the vehicle as an aid to routine checking of the installation. For stationary installations you are recommended to mark the outline of the protective field on the floor as an aid to routine checking of the installation.

The incremental encoders must meet the following requirements: – Type: Two-channel rotary encoder with 90° phase offset – Power supply: 24 V DC – Outputs: Push/pull outputs – Protection IP 54 or higher – Shielded cable – Max. pulse frequency: 100 kHz – Min. number of pulses: 50 pulses per cm Calculate for both incremental encoders the number of pulses the encoders deliver per centimetre of travel with your vehicle travelling straight ahead. You will need these values to configure the PLS/LSI user software (see section 9.7 and the calculation example in the appendix, section 12.1).

Calculating the depth of the protective field on the vehicle: Safety supplement

When calculating the required depth of protective field on a vehicle, you must take into account the fact that the increase in braking distance is quadratic and not linear as the speed rises (see diagram).

• • •

Distance

Note: For detailed information on calculation of the protective field depth and the necessary safety allowances refer to the Technical Description of the PLS.

Vehicle braking distance

Protective field depth

Define the required speed ranges for your application. Calculate the longest braking distance for each of the speed ranges (i.e. the braking distance for the upper speed limit). Add the necessary safety allowances to the distance calculated (see Technical Description of PLS).

This produces the required depth of protective field for each speed range.

•

Speed

Configure the protective fields with the aid of the PLS/LSI user software, as described in section 9.7. The braking distance of the vehicle plus the safety allowance produces the necessary protective field depth.

10

8 008 310/M848/06-05-02 Technical Description • LSI © SICK AG • Industrial Safety Systems • Germany • All rights reserved