Page 1 of Presentation Scanners Software Configuration Manual

Manual · Datalogic

Presentation Scanners Software Configuration Manual

Manual128 pagesPDF 3.1 MB

Software configuration manual with setup bar codes for Datalogic presentation scanners, including the Diamond D531.

Download the PDF3.1 MB

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

Datalogic's software configuration manual for its presentation scanner families, which have a built-in decoder and multi-standard interface. It explains the status indicators, single line mode and interface selection (USB, RS232, keyboard wedge and IBM 46xx), then gives configuration bar codes for RS232, USB and wedge parameters, data format, power save, reading and decoding parameters, code selection and advanced formatting. Reference notes, host configuration strings, a code identifier table and a hex table follow.

Its parts

  1. Configuration Methods
  2. Introduction
  3. Initial Setup
  4. Configuration
  5. References

From the manual

Key facts from this manual

Each line names its page in the PDF.

Software configuration manual for Datalogic presentation scanner families, for software version 1.0.5 and later. It does not name the Catcher D531 itself; the only model it names is the Diamond D531, in one limit. It explains setup with configuration barcodes, choosing a USB, RS232, keyboard wedge or IBM 46xx interface, the settings groups, firmware upgrades and copying a configuration between scanners.

Read for this summary: pages 1 to 5, 8 to 20, 52 to 53, 63 to 64 and 101 to 112 of 128.

Software version
Software version 1.0.5 and later p. 4
Configuration methods
Configuration barcodes; DL Sm@rtSet Windows utility over RS232 or USB-COM; copy command; configuration strings sent from the host p. 8
Interfaces
USB, RS232, keyboard wedge; IBM 46xx for IBM devices only p. 12, 19
USB modes
USB-KBD (default), USB-KBD-ALT-MODE, USB-KBD-APPLE, USB-COM, USB-IBM-Table Top, USB-IBM-Hand Held p. 13, 14
USB hosts
Windows 98 and later, Mac OS 8.0 and later, IBM POS for Windows, 4690 Operating System p. 12
RS232 modes
Standard; POS systems Nixdorf Mode A, Fujitsu, ICL Mode p. 15
Wedge hosts
IBM AT or PS/2, IBM XT, PC Notebook, IBM SURE1, IBM Terminal 3153, IBM 31xx/32xx/34xx/37xx terminals, Wyse terminals, Digital VT2xx/VT3xx/VT4xx, Apple ADB Bus p. 16, 17, 18
IBM 46xx
Port 9B or Port 5B, with 4501 Protocol or 1520 Protocol p. 19
Code families
EAN/UPC, 2/5, Code 39, Code 128, Code 93, Codabar, MSI, Plessey, RSS; up to 5 code selections p. 63, 64
Stand-by timeout
1, 5, 15 or 25 minutes p. 106
Start-up beeps
LLLL: parameters loaded or wakeup; HHHH long: parameter loading or memory error; HLHL: EEPROM hardware error p. 9
Firmware upgrades
DL Sm@rtSet Downloader from a PC over RS232 or USB p. 110
Copy cables
RS232 cables CAB363 & CAB364 or CAB320 & CAB328; power supply PG5 p. 110
Host strings
$+ command $- CR over RS232 or USB-COM; buffer about 400 characters p. 112

What this manual walks you through

  • Changing settings by reading configuration barcodes p. 8
  • Using single line mode to read one barcode among many p. 11
  • First USB start-up, drivers and bus power p. 12, 13
  • Selecting the RS232, keyboard wedge or IBM 46xx interface p. 15, 16, 17, 18, 19
  • RS232 hardware and software handshaking p. 101
  • ACK/NACK protocol and serial decode and sleep control p. 102
  • Setting custom header and terminator keys for wedge users p. 104, 105
  • Stand-by and sleep power save states p. 106
  • Saving and restoring a custom default configuration p. 109
  • Copying a configuration from a master scanner to a slave p. 110

Good to know

  • Decoding parameters used incorrectly can degrade reading or increase decoding errors. p. 107
  • Apple ADB Bus wedge is not available for the Diamond D531. p. 18
  • Reading the restore default code does not change the header and terminator selection. p. 103
  • Host strings over about 400 characters must be split into groups sent at least 3 seconds apart. p. 112
  • Caps Lock and Num Lock must be off before setting custom keys. p. 104

Questions this manual answers

How do I upgrade the firmware on a Datalogic presentation scanner?

Use the DL Sm@rtSet Downloader utility from a PC over RS232 or USB; the DL Sm@rtSet manual describes the steps. p. 110

How do I copy settings from one presentation scanner to another?

Join the master and slave with two RS232 cables (CAB363 & CAB364 or CAB320 & CAB328) and a PG5 power supply, set the slave to RS232, then read Copy Configuration with the master. p. 110

How do I restore the factory defaults?

Read the restore factory default configuration code; the quick reference manual lists the default settings. p. 109

What do four long high beeps at start-up mean?

A parameter loading error, or a read or write error in the nonvolatile memory. p. 9

Can I configure the scanner from a PC?

Yes. DL Sm@rtSet works over RS232 or USB-COM, and the host can also send configuration strings over RS232 or USB-COM. p. 8, 112

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. CONFIGURATION METHODS8
  2. INTRODUCTION9
    1. STATUS INDICATORS9
  3. INITIAL SETUP11
    1. SINGLE LINE MODE11
    2. INTERFACE SELECTION12
  4. CONFIGURATION20
    1. RS232 PARAMETERS21
    2. USB PARAMETERS28
    3. WEDGE PARAMETERS34
    4. DATA FORMAT41
    5. POWER SAVE52
    6. READING PARAMETERS55
    7. DECODING PARAMETERS59
    8. CODE SELECTION63
    9. ADVANCED FORMATTING82
  5. REFERENCES101
    1. RS232 PARAMETERS101
    2. DATA FORMAT103
    3. POWER SAVE106
    4. READING PARAMETERS107
    5. DECODING PARAMETERS107
    6. CODE SELECTION108
    7. CONFIGURATION EDITING COMMANDS109
    8. CUSTOM DEFAULT CONFIGURATION109
    9. CONFIGURATION COPY COMMAND110
    10. FIRMWARE UPGRADES110
    11. DEFAULT PARAMETERS FOR POS SYSTEMS111
  6. A HOST CONFIGURATION STRINGS112
  7. B CODE IDENTIFIER TABLE124
  8. C HEX AND NUMERIC TABLE127

From the PDF’s own bookmarks.

The whole text · 16 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 41-4
  2. CONTENTS5-7
  3. Pages 8 to 108-10
  4. INITIAL SETUP11-19
  5. CONFIGURATION, pages 20 to 2820-28
  6. CONFIGURATION, pages 29 to 3729-37
  7. CONFIGURATION, pages 38 to 4638-46
  8. CONFIGURATION, pages 47 to 5547-55
  9. CONFIGURATION, pages 56 to 6456-64
  10. CONFIGURATION, pages 65 to 7365-73
  11. CONFIGURATION, pages 74 to 8274-82
  12. CONFIGURATION, pages 83 to 9183-91
  13. CONFIGURATION, pages 92 to 10092-100
  14. REFERENCES101-111
  15. A HOST CONFIGURATION STRINGS112-123
  16. Pages 124 to 128124-128

The file

Revision and size

RevisionEd.: 11/2005, software version 1.0.5 and later
PublisherDatalogic S.p.A.
Pages128
PDF3.1 MB
TextText from the PDF itself; page 1 is a scan, read by OCR, which may hold reading errors.

The first pages · 3 of 128

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 128
Page 2
Page 2of 128
Page 3
Page 3of 128