Page 47

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DATA FORMAT

Ì$-?Î

TERMINATOR no terminator

ÌEA10-Î one character terminator

ÌEA111Î two character terminator

ÌEA125Î three character terminator

ÌEA139Î four character terminator

ÌEA14=Î five character terminator

ÌEA15AÎ six character terminator

ÌEA16EÎ seven character terminator

ÌEA17IÎ eight character terminator

ÌEA18MÎ After selecting one of the desired Terminator codes, read the character(s) from the HEX table. Example: two character terminator

+ 0D + 0A = Terminator CR LF For more details see par. 4.2.1.

39

Page 48

Enter Configuration

Ì$+;Î

Exit and Save Configuration

Ì$-?Î

DATA FORMAT FIELD ADJUSTMENT disable field adjustment

ÌEF0[Î Field adjustment allows a number of characters n, to be added to or subtracted from the barcode read. The adjustment can be different for each enabled code type. To define the field adjustment: Read the enable field adjustment code: enable field adjustment

ÌEF+Î Select the code type from the Code Identifier Table in Appendix B. Select the type of adjustment to perform: right addition

Ì01Î left addition

Ì12Î right deletion

Ì23Î left deletion

Ì34Î Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many characters to add or delete: Conditions: •

Adjustment is only performed on the barcode data, the Code Identifier and Code Length Transmission fields are not modified by the field adjustment parameter.

•

If the field setting would subtract more characters than exist in the barcode, the subtraction will take place only to code length 0.

•

You can set up to a maximum of 10 different field adjustments on the same barcode family or on different barcode families.

Example: To add 4 characters to the right of Standard Code 39 Codes: enable field adjustment

Read

40

ÌEF+Î

Code 39

+

ÌVWÎ right addition

+

Ì01Î

+

04

Page 49

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DATA FORMAT

Ì$-?Î

FIELD ADJUSTMENT CHARACTER Read the field adjustment character code: field adjustment character

ÌEG-Î Read the hexadecimal value corresponding to the character you want to use for field adjustment. Valid characters are in the range 00-FE. Example: To define the field adjustment character = A: field adjustment character

Read

+ 41

CODE LENGTH TX code length not transmitted

ÌEE0YÎ code length transmitted in variable-digit format

ÌEE1\Î code length transmitted in fixed 4-digit format

ÌEE2_Î The code length is transmitted in the message after the Headers and Code Identifier characters. The code length is calculated after performing any field adjustment operations.

41

Page 50

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DATA FORMAT

Ì$-?Î

CHARACTER REPLACEMENT disable character replacement

ÌEO0mÎ This parameter allows up to three characters to be replaced from the barcode read. These substitutions are stored in memory. To define each character replacement:

Read one of the following character replacement codes: first character replacement

ÌEO1pÎ second character replacement

ÌEO2sÎ third character replacement

ÌEO3vÎ From the Code Identifier Table in Appendix B, read the Code Identifier for the desired code family. 0 = character replacement will be effective for all code families. From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the character to be replaced.

From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the new character to replace. FF = the character to be replaced will be substituted with no character, that is, it will be removed from the code.

42

Page 51

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

DATA FORMAT

Example: The following strings define: 1.

First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character.

2.

Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character.

first character replacement

Code 39

ÌEO1pÎ + ÌVWÎ +

ASCII characters corresponding to the HEX value for character 0

30

ASCII characters corresponding to the HEX value for character 1

+

31

For Code 39 codes containing the string "0123", the contents transmitted will be "1123".

second character replacement

Code 39

ÌEO2sÎ + ÌVWÎ +

ASCII characters corresponding to the HEX value for character A

41

ASCII characters corresponding to the HEX value for character B

+

42

For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".

43

Page 52

POWER SAVE STAND-BY STATE ENTER STAND-BY TIMEOUT SLEEP STATE ENTER SLEEP TIMEOUT

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups. = Read the code and follow the procedure given = Default value

3.

44

Read the Exit and Save Configuration code ONCE, available at the top of each page.

Page 53

Enter Configuration

Ì$+;Î

Exit and Save Configuration

POWER SAVE

Ì$-?Î

STAND-BY STATE disable

ÌBf01Î enable

ÌBf14Î See par. 4.3.1 for details.

ENTER STAND-BY TIMEOUT 1 minute

ÌBg04ÇÎ 5 minutes

ÌBg20yÎ 15 minutes

ÌBg60ÉÎ 25 minutes

ÌBg99KÎ See par. 4.3.2 for details.

45

Page 54

Enter Configuration

Exit and Save Configuration

Ì$+;Î

POWER SAVE

Ì$-?Î

SLEEP STATE disable

ÌBQ0nÎ enable

ÌBQ1qÎ See par. 4.3.3 for details.

ENTER SLEEP TIMEOUT enter sleep timeout

ÌBinÎ Read 2 numbers in the range 01-99: 01-99 = corresponds to a max. 99 min. delay before entering the Sleep state.

See par. 4.3.4 for details.

46

Page 55

READING PARAMETERS TIMEOUT BETWEEN SAME CODE READINGS

SINGLE LINE DECODING DURATION SINGLE LINE TIMEOUT OFF BEFORE RASTER BEEPER INTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups. = Read the code and follow the procedure given = Default value

3.

Read the Exit and Save Configuration code ONCE, available at the top of each page.

47