Page 47
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DATA FORMAT
Ì$-?Î
TERMINATOR no terminator
ÌEA10-Î one character terminator
ÌEA111Î two character terminator
ÌEA125Î three character terminator
ÌEA139Î four character terminator
ÌEA14=Î five character terminator
ÌEA15AÎ six character terminator
ÌEA16EÎ seven character terminator
ÌEA17IÎ eight character terminator
ÌEA18MÎ After selecting one of the desired Terminator codes, read the character(s) from the HEX table. Example: two character terminator
+ 0D + 0A = Terminator CR LF For more details see par. 4.2.1.
39
Page 48
Enter Configuration
Ì$+;Î
Exit and Save Configuration
Ì$-?Î
DATA FORMAT FIELD ADJUSTMENT disable field adjustment
ÌEF0[Î Field adjustment allows a number of characters n, to be added to or subtracted from the barcode read. The adjustment can be different for each enabled code type. To define the field adjustment: Read the enable field adjustment code: enable field adjustment
ÌEF+Î Select the code type from the Code Identifier Table in Appendix B. Select the type of adjustment to perform: right addition
Ì01Î left addition
Ì12Î right deletion
Ì23Î left deletion
Ì34Î Read a number in the range 01 - 32 from the Hex/Numeric Table to define how many characters to add or delete: Conditions: •
Adjustment is only performed on the barcode data, the Code Identifier and Code Length Transmission fields are not modified by the field adjustment parameter.
•
If the field setting would subtract more characters than exist in the barcode, the subtraction will take place only to code length 0.
•
You can set up to a maximum of 10 different field adjustments on the same barcode family or on different barcode families.
Example: To add 4 characters to the right of Standard Code 39 Codes: enable field adjustment
Read
40
ÌEF+Î
Code 39
+
ÌVWÎ right addition
+
Ì01Î
+
04
Page 49
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DATA FORMAT
Ì$-?Î
FIELD ADJUSTMENT CHARACTER Read the field adjustment character code: field adjustment character
ÌEG-Î Read the hexadecimal value corresponding to the character you want to use for field adjustment. Valid characters are in the range 00-FE. Example: To define the field adjustment character = A: field adjustment character
Read
+ 41
CODE LENGTH TX code length not transmitted
ÌEE0YÎ code length transmitted in variable-digit format
ÌEE1\Î code length transmitted in fixed 4-digit format
ÌEE2_Î The code length is transmitted in the message after the Headers and Code Identifier characters. The code length is calculated after performing any field adjustment operations.
41
Page 50
Enter Configuration
Ì$+;Î
Exit and Save Configuration
DATA FORMAT
Ì$-?Î
CHARACTER REPLACEMENT disable character replacement
ÌEO0mÎ This parameter allows up to three characters to be replaced from the barcode read. These substitutions are stored in memory. To define each character replacement:
Read one of the following character replacement codes: first character replacement
ÌEO1pÎ second character replacement
ÌEO2sÎ third character replacement
ÌEO3vÎ From the Code Identifier Table in Appendix B, read the Code Identifier for the desired code family. 0 = character replacement will be effective for all code families. From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the character to be replaced.
From the Hex/Numeric Table read two characters corresponding to the Hex value (00-FE) which identifies the new character to replace. FF = the character to be replaced will be substituted with no character, that is, it will be removed from the code.
42
Page 51
Enter Configuration
Exit and Save Configuration
Ì$+;Î
Ì$-?Î
DATA FORMAT
Example: The following strings define: 1.
First Character Replacement: substitution in Code 39 barcodes of all occurrences of the 0 character with the 1 character.
2.
Second Character Replacement: substitution in Code 39 barcodes of all occurrences of the A character with the B character.
first character replacement
Code 39
ÌEO1pÎ + ÌVWÎ +
ASCII characters corresponding to the HEX value for character 0
30
ASCII characters corresponding to the HEX value for character 1
+
31
For Code 39 codes containing the string "0123", the contents transmitted will be "1123".
second character replacement
Code 39
ÌEO2sÎ + ÌVWÎ +
ASCII characters corresponding to the HEX value for character A
41
ASCII characters corresponding to the HEX value for character B
+
42
For Code 39 codes containing the string "ABCD", the contents transmitted will be "BBCD".
43
Page 52
POWER SAVE STAND-BY STATE ENTER STAND-BY TIMEOUT SLEEP STATE ENTER SLEEP TIMEOUT
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given = Default value
3.
44
Read the Exit and Save Configuration code ONCE, available at the top of each page.
Page 53
Enter Configuration
Ì$+;Î
Exit and Save Configuration
POWER SAVE
Ì$-?Î
STAND-BY STATE disable
ÌBf01Î enable
ÌBf14Î See par. 4.3.1 for details.
ENTER STAND-BY TIMEOUT 1 minute
ÌBg04ÇÎ 5 minutes
ÌBg20yÎ 15 minutes
ÌBg60ÉÎ 25 minutes
ÌBg99KÎ See par. 4.3.2 for details.
45
Page 54
Enter Configuration
Exit and Save Configuration
Ì$+;Î
POWER SAVE
Ì$-?Î
SLEEP STATE disable
ÌBQ0nÎ enable
ÌBQ1qÎ See par. 4.3.3 for details.
ENTER SLEEP TIMEOUT enter sleep timeout
ÌBinÎ Read 2 numbers in the range 01-99: 01-99 = corresponds to a max. 99 min. delay before entering the Sleep state.
See par. 4.3.4 for details.
46
Page 55
READING PARAMETERS TIMEOUT BETWEEN SAME CODE READINGS
SINGLE LINE DECODING DURATION SINGLE LINE TIMEOUT OFF BEFORE RASTER BEEPER INTENSITY BEEPER TONE BEEPER TYPE BEEPER LENGTH
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given = Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.