Page 56

Enter Configuration

Exit and Save Configuration

Ì$+;Î

READING PARAMETERS

Ì$-?Î

TIMEOUT BETWEEN SAME CODE READINGS timeout between same code readings

ÌBhlÎ Limits same code consecutive reading. Read 2 numbers in the range 01-99: 01 to 99 = timeout from 0.1 to 9.9 seconds for which the code must be removed (no decoding) before a consecutive read on same code. timeout = 0.3 sec See par. 4.4.1 for details.

SINGLE LINE DECODING DURATION single line decoding duration

ÌBddÎ Read 2 numbers in the range 01-20: 01 to 20 = timeout from 1 to 20 seconds before passing to the Single Line Timeout OFF Before Raster. duration = 5 sec See par. 4.4.2 details.

48

Page 57

Enter Configuration

Ì$+;Î

Exit and Save Configuration

READING PARAMETERS

Ì$-?Î

SINGLE LINE TIMEOUT OFF BEFORE RASTER single line timeout OFF before raster

ÌBefÎ Read 1 number in the range 1-9: 1 to 9 = timeout from 1 to 9 seconds before re-entering Raster mode. timeout = 2 sec

See par. 4.4.3 for details.

BEEPER INTENSITY beeper off *

ÌBG0ZÎ low intensity

ÌBG1]Î medium intensity

ÌBG2`Î high intensity

ÌBG3cÎ * This sets the beeper OFF for data entry, while for all other beeper signals it has the meaning “very low intensity”. The Beeper Intensity parameter is effective for all operating conditions described in par. 1.1.

49

Page 58

Enter Configuration

Ì$+;Î

Exit and Save Configuration

READING PARAMETERS

Ì$-?Î

BEEPER TONE tone 1

ÌBH0\Î tone 2

ÌBH1_Î tone 3

ÌBH2bÎ tone 4

ÌBH3eÎ BEEPER TYPE monotone

ÌBJ0`Î bitonal

ÌBJ1cÎ BEEPER LENGTH long

ÌBI0^Î short

ÌBI1aÎ

50

Page 59

DECODING PARAMETERS INK SPREAD OVERFLOW CONTROL INTERDIGIT CONTROL CODE 39 STITCHING CODE 128 STITCHING DECODING SAFETY

Before changing these parameter values read the descriptions in par. 4.5. CAUTION

1. 2. 3.

Read the Enter Configuration code ONCE, available at the top of each page. Read configuration codes from the desired groups. = Default value

Read the Exit and Save Configuration code ONCE, available at the top of each page.

51

Page 60

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DECODING PARAMETERS INK SPREAD disable

ÌAX0{Î enable

ÌAX1~Î See par. 4.5.1 for details.

OVERFLOW CONTROL disable

ÌAW1|Î enable

ÌAW0yÎ See par. 4.5.2 for details.

52

Ì$-?Î

Page 61

Enter Configuration

Ì$+;Î

Exit and Save Configuration

DECODING PARAMETERS

Ì$-?Î

CODE 39 STITCHING disable

ÌAa0&Î enable

ÌAa1)Î See par. 4.5.4 for details.

CODE 128 STITCHING disable

ÌAc0*Î enable

ÌAc1-Î See par. 4.5.4 for details.

53

Page 62

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î

DECODING PARAMETERS INTERDIGIT CONTROL disable

ÌAV0wÎ enable

ÌAV1zÎ See par. 4.5.3 for details.

DECODING SAFETY one read

ÌED0WÎ (decoding safety disabled) two reads

ÌED1ZÎ three reads

ÌED2]Î four reads

ÌED3`Î Required number of good reads before accepting code.

54

Page 63

CODE SELECTION EAN/UPC FAMILY 2/5 FAMILY CODE 39 FAMILY CODE 128 FAMILY CODE 93 CODABAR FAMILY MSI PLESSEY RSS CODES

1.

Read the Enter Configuration code ONCE, available at the top of each page.

2.

Read configuration codes from the desired groups. = Read the code and follow the procedure given = Default value

3.

Read the Exit and Save Configuration code ONCE, available at the top of each page.

55

Page 64

Enter Configuration

Exit and Save Configuration

Ì$+;Î

CODE SELECTION

Ì$-?Î

DISABLES ALL CODE FAMILIES

ÌAZ0ÃÎ The scanner allows up to 5 code selections. This does not limit the number of CODES enabled to 5, as it depends on the code family. NOTE

SINGLE SELECTIONS =

•

ONE combination code from the EAN family

•

ONE code from the 2/5 family

Example 5 code selections:

1. 2/5 Interleaved 2. 2/5 Industrial 3. Code 128 + EAN 128 4. Code 39 Full ASCII + Code 32 5. UPC A/UPC E

In this section all SINGLE code selections are underlined and in bold.