Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 13 of 16

Presentation Scanners Software Configuration Manual: CONFIGURATION, pages 92 to 100

Pages 92 to 100 of 128, from Presentation Scanners Software Configuration Manual

The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Datalogic Catcher D531

Page 92

Exit and Save Configuration

Ì$-?Î

ADVANCED FORMATTING DEFINE FIELD 3 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator

Ì01Î

Ì12Î OR match character

ÌHG3iÎ b)

Read the match character from the HEX table. Range of characters = 01-FE. OR field length

ÌHG1cÎ c)

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

ÌHG2fÎ d)

AND Field 3 Terminators no field terminators

ÌHH0bÎ 1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character.

84

Page 93

Exit and Save Configuration

Ì$-?Î

ADVANCED FORMATTING DEFINE FIELD 4 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator

Ì01Î

Ì12Î OR match character

ÌHG3iÎ b)

Read the match character from the HEX table. Range of characters = 01-FE. OR field length

ÌHG1cÎ c)

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

ÌHG2fÎ d)

AND Field 4 Terminators no field terminators

ÌHH0bÎ 1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character.

85

Page 94

Exit and Save Configuration

Ì$-?Î

ADVANCED FORMATTING DEFINE FIELD 5 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator

Ì01Î

Ì12Î OR match character

ÌHG3iÎ b)

Read the match character from the HEX table. Range of characters = 01-FE. OR field length

ÌHG1cÎ c)

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

ÌHG2fÎ d)

AND Field 5 Terminators no field terminators

ÌHH0bÎ 1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character.

86

Page 95

Exit and Save Configuration

ADVANCED FORMATTING 7

Ì$-?Î

First Additional Fixed Field no fixed field

ÌHI0dÎ 1 character fixed field

ÌHI1gÎ 2 character fixed field

ÌHI2jÎ 3 character fixed field

ÌHI3mÎ 4 character fixed field

ÌHI4pÎ 5 character fixed field

ÌHI5sÎ 6 character fixed field

ÌHI6vÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character. Example: 4 Character Fixed Field

+ 4D + 41 + 49 + 4E =

MAIN

87

Page 96

Exit and Save Configuration

ADVANCED FORMATTING 8

Ì$-?Î

Second Additional Fixed Field no fixed field

ÌHJ0fÎ 1 character fixed field

ÌHJ1iÎ 2 character fixed field

ÌHJ2lÎ 3 character fixed field

ÌHJ3oÎ 4 character fixed field

ÌHJ4rÎ 5 character fixed field

ÌHJ5uÎ 6 character fixed field

ÌHJ6xÎ After selecting one of the Additional Fixed Field codes, read the corresponding character(s) from the HEX table. Range of characters = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character. Example: 3 Character Fixed Field

+ 53 + 45 + 54 =

88

SET

Page 97

Exit and Save Configuration

ADVANCED FORMATTING 9

Ì$-?Î

Field Transmission number of fields to transmit

ÌHK8Î Read one number in the range 1 to 7 for the number of fields to transmit. Include only fields to be transmitted. Field Order Transmission Read the codes corresponding to the fields to transmit in the order in which they are to be transmitted. A field can be transmitted more than once. See example. field 1

Ì12Î field 2

Ì23Î field 3

Ì34Î field 4

Ì45Î field 5

Ì56Î additional field 1

Ì67Î additional field 2

Ì78Î Example: The barcode is divided into 3 defined fields plus 1 additional fixed field. Transmit in the order: Field 2, Additional Field 1, Field 1, Field 2. Number of Fields to Transmit

Field 2

+4+

Additional Field 1

+

Field 1

+

Field 2

+

89

Page 98

Exit and Save Configuration

ADVANCED FORMATTING 10

Ì$-?Î

Standard Formatting do not apply standard formatting

ÌHL0jÎ apply standard formatting

ÌHL1mÎ After performing Advanced Formatting on the barcode read, Standard Formatting (Headers, Code Length, Code ID, Terminators) can be applied to the message to be transmitted.

11

End Format Definition end Format 1 definition

ÌHM0lÎ end Format 2 definition

ÌHM1oÎ end Format 3 definition

ÌHM2rÎ end Format 4 definition

ÌHM3uÎ

90

Page 99

Enter Configuration

Ì$+;Î

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

Enable Advanced Format no Advanced Formats enabled

ÌHN0nÎ Advanced Format 1 enable

ÌHN11NÎ disable

ÌHN10JÎ Advanced Format 2 enable

ÌHN21QÎ disable

ÌHN20MÎ Advanced Format 3 enable

ÌHN31TÎ disable

ÌHN30PÎ Advanced Format 4 enable

ÌHN41WÎ disable

ÌHN40SÎ

91

Page 100

Enter Configuration

Ì$+;Î

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

No Match Result clear data - no transmission

ÌHO0pÎ transmit data using standard format

ÌHO1sÎ This selection determines the action to be taken when codes read do not conform to the advanced format requisites (no match).

92

•

Codes not matching can be ignored, cleared from memory and not transmitted.

•

Codes not matching can be transmitted using the Standard formatting (Headers, Code Length, Code ID, Terminators).