Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 14 of 16

Presentation Scanners Software Configuration Manual: REFERENCES

Pages 101 to 111 of 128, from Presentation Scanners Software Configuration Manual

The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Datalogic Catcher D531

Page 101

REFERENCES

4

4

REFERENCES

4.1

RS232 PARAMETERS

4.1.1

Handshaking

Hardware handshaking: (RTS/CTS) The RTS line is activated by the decoder before transmitting a character. Transmission is possible only if the CTS line (controlled by the Host) is active. Signals at EIA levels

RTS

TX Transmitted data

Transmitted data

Host busy

CTS

RTS/CTS handshaking

Software handshaking: (XON/XOFF) During transmission, if the Host sends the XOFF character (13 Hex), the decoder interrupts the transmission with a maximum delay of one character and only resumes when the XON character (11 Hex) is received. Transmitted data

Transmitted data

TX

RX XOFF Host busy

XON Host ready

XON/XOFF handshaking

93

Page 102

PRESENTATION SCANNERS

4

4.1.2

ACK/NACK Protocol

This parameter sets a transmission protocol in which the Host responds to the scanner after every code transmitted. The Host sends an ACK character (06 HEX) in the case of good reception or the NACK character (15 HEX) requesting retransmission, in the case of bad reception. If the scanner does not receive an ACK or NACK, transmission is ended after the RX Timeout (see par. 4.1.3).

4.1.3

RX Timeout

When the RS232 interface is selected, the Host can be used to configure the device by sending it command strings (see appendix A). This parameter can be used to automatically end data reception from the Host after the specified period of time. If no character is received from the Host, after the timeout expires, any incomplete string (any string not terminated by <CR>) is flushed from the device buffer.

4.1.4

Serial Decode Control

This parameter allows defining two ASCII characters that control whether the scanner is enabled to decode barcodes or not. When this parameter is enabled and the first defined character is sent over the serial line, decoding is enabled. When the second defined character is sent over the serial line, decoding is disabled until the first character is received again. If Serial Sleep Enabling is used the characters must be different.

4.1.5

Serial Sleep Control

This parameter allows defining two ASCII characters that control when the scanner enters sleep and wakeup states. When this parameter is enabled and the first defined character is sent over the serial line, the scanner immediately enters the sleep state. When the second defined character is sent over the serial line, the scanner immediately wakesup. If Serial Decode Enabling is used the characters must be different.

94

Page 103

REFERENCES

4.2

4

DATA FORMAT

4.2.1

Header/Terminator Selection

The header/terminator selection is not effected by the reading of the restore default code. In fact, header and terminator default values depend on the interface selection: RS232 and USB-COM: WEDGE and USB-KBD: WEDGE ALT-MODE and USB-KBD-ALT-MODE:

no header, terminator CR-LF no header, terminator ENTER no header, terminator CR

These default values are always restored through the reading of the relative interface selection code, see chapter 2.2 For the WEDGE interface, the following extended keyboard values can also be configured: EXTENDED KEYBOARD TO HEX CONVERSION TABLE IBM AT IBM 3153 APPLE ADB

IBM XT

IBM 31xx, 32xx, 34xx, 37xx

Wyse Digital

HEX

KEY

KEY

KEY

KEY

83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A 9B

ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 HOME END PG UP PG DOWN ↑ ↓ ← → ESC CTRL (Right) Euro

ENTER TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 ESC BACKSPACE HOME END PG UP PG DOWN ↑ ↓ ← → ESC CTRL (Right) Space

FIELD EXIT TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 ENTER RESET INSERT DELETE FIELD FIELD + ENTER (Paddle) PRINT

RETURN TAB F1 F2 F3 F4 F5 F6 F7 F8 F9 F10 F11 F12 F13 F14 F15 F16 UP DOWN LEFT RIGHT ESC CTRL (Right) Space

Space

For all scanners using Wedge interface, all values from 9C to FE send the Space character.

95

Page 104

PRESENTATION SCANNERS

4

4.2.2

Set Custom Extended Header/Terminator Keys

The extended Header/Terminator keys for Wedge Interface users can be customized by defining them through a simple keyboard setting procedure. For example, the Numeric Keypad keys can be set for use as Headers or Terminators by substituting the default extended keys using this procedure. The type of computer or terminal must be selected before activating the keyboard setting command. Press and release a key to set it. Some characters may require more than one key pressed simultaneously during normal use (refer to the manual of your PC or terminal for keyboard use). The exact sequence must be indicated to the scanner in this case pressing and releasing the different keys. Example: If one has to press the "Shift" and "4" keys simultaneously on the keyboard to transmit the character "$" to the video, to set the "$", press and release "Shift" then press and release "4". Each pressed and released key must generate an acoustic signal on the scanner, otherwise repress the key. Never press more than one key at the same time, even if this corresponds to the normal use of your keyboard. Press "Backspace" to correct a wrong key entry. In this case the scanner emits 2 beeps. Note: "CAPS LOCK" and "NUM LOCK" must be off before starting the keyboard setting procedure. "SHIFT" must be repressed for each character and cannot be substituted by "CAPS LOCK".

96

Page 105

Enter Configuration

Exit and Save Configuration

Ì$+;Î

Ì$-?Î Set Custom Extended Header/Terminator Keys

ÌFB1WÎ Read the code above. •

If the first 4 KEYS (Shift, Alt, Ctrl, and Backspace) are not available on your keyboard, you can only substitute them with keys not used, or substitute them with each other.

•

Keys 5 to 28 must be defined

Press the desired keys in the following order: The scanner signals the end of the procedure with 2 beeps indicating the keys have been registered.

CUSTOM EXTENDED KEYBOARD SETTING TABLE Custom Order

HEX

KEY

01 02 03 04 05 06 07 08 09 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28

83 84 85 86 87 88 89 8A 8B 8C 8D 8E 8F 90 91 92 93 94 95 96 97 98 99 9A

Shift Alt Ctrl Backspace

97

Page 106

PRESENTATION SCANNERS

4

4.3

POWER SAVE

4.3.1

Stand-by State

This is a low-power operating mode in which the scanner is still operating but decoding cannot take place. The scanner enters Stand-by after the configured timeout, during which no codes are presented to it. It is possible to exit Stand-by mode (return to normal operation) by presenting a code to the scanner (the scanner automatically wakes up) or by pressing the trigger.

4.3.2

Enter Stand-by timeout

For scanners that have the Stand-by state enabled, this timeout, during which no codes are presented to the scanner, determines when the scanner will enter this state. The valid values are: 1, 5, 15, and 25 minutes.

4.3.3

Sleep State

This allows the scanner to enter a "Sleep" state for minimum power consumption in which the scanner Laser is OFF and the motor is not rotating. Before entering Sleep mode, the following are verified: • no data being transmitted to Host

•

Enter Sleep Timeout ended (see par. 4.3.4)

It is possible to exit Sleep mode by pressing the trigger.

4.3.4

Enter Sleep Timeout

For scanners that have the Sleep state enabled, this timeout, during which no codes are presented to the scanner, determines when the scanner will enter this state. This timeout begins after the Stand-by timeout ends (if Stand-by State is enabled), otherwise it begins immediately.

98

Page 107

REFERENCES

4.4

4

READING PARAMETERS

4.4.1

Timeout between Same Code Readings

This timeout prevents the device from immediately decoding one or more codes (of those present in the same reading area) more than once. Any decoded code must be removed from the reading area for the duration of the configured timeout before it can be decoded again.

4.4.2

Single Line Decoding Duration

Single Line Mode allows aiming a single scan line across a barcode for decoding. The first trigger press allows aiming the single line without decoding. After the second trigger press (which must occur within 5 seconds) the code can be decoded. The Single Line Decoding Duration parameter sets the timeout during which the scanner continues to attempt code decoding. When the timeout expires, the scanner passes to the Single Line Timeout OFF before Raster parameter before returning to Raster Mode.

4.4.3

Single Line Timeout OFF before Raster

This parameter sets a timeout, after the decoding process has been completed (either due to a good read or Single Line Decoding Duration timeout expired), during which the Laser is OFF before returning to Raster mode. If the trigger is pressed before this timeout expires, the scanner returns to Single Line Mode (aiming without decoding).

4.5

DECODING PARAMETERS

CAUTION

4.5.1

These parameters are intended to enhance the decoding capability of the scanner for particular applications. Used incorrectly, they can degrade the reading performance or increase the possibility of a decoding error.

Ink-Spread

The ink-spread parameter allows the decoding of codes which are not perfectly printed because the page texture tends to absorb the ink.

99

Page 108

PRESENTATION SCANNERS

4

4.5.2

Overflow Control

The overflow control parameter can be disabled when decoding codes printed on small surfaces, which don’t allow the use of an overflow space. This command does not effect code families 2/5, Code 128 and Code 93.

4.5.3

Interdigit Control

The interdigit control parameter verifies the interdigit spacing for code families Code 39 and Codabar.

4.5.4

Code Stitching

The code stitching parameter allows decoding codes that are not entirely crossed by a single laser line or are of poor print quality, and/or damaged print. It does this by adding together (stitching), two partial reads of a code to complete the entire code. For code 39 and code 128, this parameter can be disabled if MISREADS are produced.

4.6 4.6.1

CODE SELECTION Set EAN/UPC Autodiscriminate Decoding Safety

When EAN/UPC codes are enabled with and without ADD ON, this parameter assures that codes without ADD ON will only be transmitted after decoding them n number of times (15 default).

100

Page 109

REFERENCES

4.7

4

CONFIGURATION EDITING COMMANDS

The following commands carry out their specific function and then exit the configuration environment. Command

Description

Ì$+$*oÎ

Restore factory default configuration (see the relative Quick Reference Manual for default settings)

Ì$+$!KÎ

Transmit the Software release.

Ì$+$&_Î

Transmit the device configuration in ASCII format.

4.8

CUSTOM DEFAULT CONFIGURATION

Read the following code to set the scanner user-defined configuration as custom default configuration: Save User-defined Configuration as Custom Default

Ì$+$0ÂÎ Read the following code whenever you need to restore the custom default configuration: Restore Custom Default Configuration

Ì$+$1$Î

101

Page 110

PRESENTATION SCANNERS

4

4.9

CONFIGURATION COPY COMMAND

Procedure: Connect the master (correctly configured scanner) and the slave (scanner to be configured) together through two RS232 serial interface cables and external power supply. Accessory cables and power supply are available from your Datalogic distributor to provide this connection. RS232 Cables: CAB363 & CAB364 or CAB320 & CAB328 Power Supply: PG5 Using the slave device, read the Restore Default barcode and then the RS232 interface barcode from par. 2.2.2 of this manual or from the Quick Reference Manual. With the master device, read the Configuration Copy barcode below.

Copy Configuration

Ì$+ZZ0$-*Î

The configuration will be copied from the master to the slave device. The slave device signals the end of the procedure with a series of beeps. Note: The master device can be configured for any interface.

4.10 FIRMWARE UPGRADES Device firmware upgrades can be performed using the DL Sm@rtSet external Downloader utility tool from your PC either through RS232 or USB communications. The procedure for downloading is described in the DL Sm@rtSet User's Manual and in the Help window.

102

Page 111

REFERENCES

4

4.11 DEFAULT PARAMETERS FOR POS SYSTEMS The default values for the RS232 and Data Format parameters for POS systems are listed in the following table:

RS232 Group Baud Rate Parity Data Bits Stop Bits Handshaking ACK/NACK Protocol Inter-Character Delay RX Timeout Serial Decode Enabling Serial Sleep Enabling Data Format Group Code Identifier Header Terminator Field Adjustment Code Length TX Character Replacement

NIXDORF Mode A

FUJITSU

ICL Mode

9600 Odd 8 1 Hardware (RTS/CTS) Disabled Disabled 9.9 sec

9600 None 8 1 None Disabled Disabled 2 sec

9600 Even 8 1 RTS always on Disabled Disabled 9.9 sec

Custom No Header CR Disabled Not Transmitted Disabled

Custom Custom No Header No Header CR CR Disabled Disabled Not Transmitted Not Transmitted Disabled Disabled

The table below lists all the Code Identifiers available for POS systems: CODE UPC-A UPC-E EAN-8 EAN-13 Code 39 Codabar Code 128 Interleaved 2 of 5 Code 93 Industrial 2 of 5 UCC/EAN 128 MSI/Plessey RSS Other

NIXDORF Mode A A0 C B A M N K I L H P O E None

FUJITSU A E FF F None None None None None None None None None None

ICL Mode A E FF F C [code length] N [code length] L [code length] I [code length] None H [code length] L [code length] None None None

103