Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 15 of 16

Presentation Scanners Software Configuration Manual: A HOST CONFIGURATION STRINGS

Pages 112 to 123 of 128, from Presentation Scanners Software Configuration Manual

The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

Filed in the catalog under the Datalogic Catcher D531

Page 112

PRESENTATION SCANNERS

A

A

HOST CONFIGURATION STRINGS

In this section we provide a description of how to modify the device configuration using serial strings sent from the Host. This method requires either the RS232 or USB-COM interface. The device configuration can be changed by receiving commands from the Host through the serial interface. When this method is used, the programming sequence format is the following:

$+

Command

$-

CR Carriage return character (0D Hex.) Exit and Save configuration

Character sequence in following tables Enter configuration environment

Example: Multiple command programming sequence: $+

BG1 BH0

AC410132

$-

CR

Carriage return character (0D Hex.) Exit and save new configuration Matrix 2/5 3 bars: no check digit, variable length code from 1 to 32 characters Beeper tone 1 Beeper low intensity Enter configuration environment

Each configuration parameter setting removes the condition previously active for that parameter.

NOTE

104

The device buffer can contain about 400 characters. If your programming string goes over this value, you must split it into separate groups and send each group after a delay of at least 3 seconds to give the scanner time to empty the buffer and interpret the commands.

Page 113

HOST CONFIGURATION STRINGS

A

SERIAL CONFIGURATION STRINGS ENTER/EXIT CONFIGURATION COMMANDS DESCRIPTION Enter Configuration Exit and Save Configuration Restore Factory Default Transmit Software Release Transmit Configuration

STRING $+ $$+$* $+$! $+$&

INTERFACE SELECTION DESCRIPTION RS232 Standard ICL Mode Fujitsu Nixdorf Mode A USB USB-KBD USB-KBD-ALT-MODE USB-KBD-APPLE USB-COM USB-IBM-Table Top USB-IBM-Hand Held WEDGE for IBM AT for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-break keyboard for IBM Terminals: 31xx, 32xx, 34xx, 37xx; make-only keyboard Keyboard Type for IBM Terminals typewriter 31xx, 32xx, 34xx, 37xx advanced for IBM XT for IBM Terminal 3153 for IBM PC Notebook for IBM SURE1 for IBM AT - ALT mode for IBM PC Notebook - ALT mode for Wyse Terminal - ANSI Keyboard for Wyse Terminal - PC Keyboard for Wyse Terminal - ASCII Keyboard for Wyse Terminal - VT220 style Keyboard for Digital Terminals VT2xx/3xx/4xx for Apple ADB Bus IBM 46xx 4501 Protocol 1520 Protocol

STRING CP0 CM0 CM1 CM2EC0 UA03 UA04 UA05 UA02 UA00 UA01 CP500 CP501 CP502 FK0 FK1 CP503 CP504 CP505 CP506 CP507 CP508 CP509 CP510 CP511 CP514 CP512 CP513 CP800 CP801

105

Page 114

PRESENTATION SCANNERS

A RS232 DESCRIPTION Baud Rate

300 600 1200 2400 4800 9600 19200 38400 Parity none even odd Data Bits 7 8 Stop Bits 1 2 Handshaking disable RTS/CTS XON/XOFF RTS always ON ACK/NACK Protocol disable enable Inter-character Delay (ms) RX Timeout (100 ms) Serial Decode Control disable enable Serial Sleep Control disable enable

STRING CD1 CD2 CD3 CD4 CD5 CD6 CD7 CD8 CC0 CC1 CC2 CA0 CA1 CB0 CB1 CE0 CE1 CE2 CE3 ER0 ER1 CK00 - CK99 CL00 - CL99 CR0 CR1ab CS0 CS1ab a = Hex value of the ASCII character from 00 to FE enabling the decoding or the serial sleep; b = Hex value of the ASCII character from 00 to FE disabling the decoding or the serial sleep;

106

Page 115

HOST CONFIGURATION STRINGS

A USB

DESCRIPTION USB-COM Handshaking

ACK/NACK Protocol Inter-character Delay (ms) RX Timeout (100 ms) Serial Decode Control Serial Sleep Control USB-KBD Keyboard Nationality (not for USB-KBD-ALT-MODE)

Delays Control Character Emulation

STRING disable RTS/CTS XON/XOFF RTS always ON disable enable disable enable disable enable

CE0 CE1 CE2 CE3 ER0 ER1 CK00 - CK99 CL00 - CL99 CR0 CR1ab CS0 CS1ab

Belgian English French German Italian Spanish Swedish USA Japanese Inter-Character (ms) Inter-Code (s) CTRL +Shift + Key Ctrl + Key

FJ7 FJ4 FJ2 FJ3 FJ1 FJ6 FJ5 FJ0 FJ8 CK00 - CK99 FG00 - FG99 FO0 FO1 a = Hex value of the ASCII character from 00 to FE enabling the decoding or the serial sleep; b = Hex value of the ASCII character from 00 to FE disabling the decoding or the serial sleep;

107

Page 116

PRESENTATION SCANNERS

A WEDGE DESCRIPTION Keyboard Nationality

Caps Lock Caps Lock Auto-Recognition (IBM AT compatible only) Num Lock Delays Control Character Emulation

108

Belgian English French German Italian Spanish Swedish USA Japanese (IBM AT compatible only) caps Lock ON caps Lock OFF disable enable Toggle Num Lock Num Lock Unchanged Inter-Character (ms) Inter-Code (s) CTRL +Shift + Key Ctrl + Key

STRING FJ7 FJ4 FJ2 FJ3 FJ1 FJ6 FJ5 FJ0 FJ8 FE1 FE0 FP0 FP1 FL1 FL0 CK00 - CK99 FG00 - FG99 FO0 FO1

Page 117

HOST CONFIGURATION STRINGS

A DATA FORMAT

DESCRIPTION Code Identifier disable Datalogic standard AIM standard Custom

Custom Code Identifier Headers

Terminators no header one character two characters three characters four characters five characters six characters seven characters eight characters no terminator one character two characters three characters four characters five characters six characters seven characters eight characters

STRING EB0 EB1 EB2 EB3 EHabc EA00 EA01x EA02xx EA03xxx EA04xxxx EA05xxxxx EA06xxxxxx EA07xxxxxxx EA08xxxxxxxx EA10 EA11x EA12xx EA13xxx EA14xxxx EA15xxxxx EA16xxxxxx EA17xxxxxxx EA18xxxxxxxx a = ASCII character. b, c, x = HEX values representing an ASCII character. a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 34. b = Hex value of the first Custom Code Identifier character from 00 to FE; FF = disable Code Identifier c = Hex value of the second Custom Code Identifier character from 00 to FE; FF = disable second character of Custom Code Identifier x = Hex value from 00 to FE

109

Page 118

PRESENTATION SCANNERS

A DATA FORMAT (continued) DESCRIPTION Code Length Tx not transmitted transmitted transmitted in 4-digit format disabled right addition left addition right deletion left deletion

Field Adjustment

Field Adjustment Character Character Replacement disable character replacement first character replacement second character replacement third character replacement

STRING EE0 EE1 EE2 EF0 EFa0d EFa1d EFa2d EFa3d EGe EO0 EO1afg EO2afg EO3afg a = ASCII character. d = a number from the Hex/Numeric Table. e, f, g = HEX values representing an ASCII character. a = ASCII character of the DATALOGIC STANDARD Code Identifier from the table on page 34. d = a number in the range 01 – 32 from the Hex/Numeric Table e = Hex value from 00 to FE f = Hex value of the character to be replaced from 00 to FE g= Hex value of the new character to insert from 00 to FE FF = replace with no new character (remove character)

POWER SAVE DESCRIPTION Stand by State Enter Stand by Timeout

Sleep State Enter Sleep Timeout (min)

110 disable enable 1 min 5 mins. 15 mins. 25 mins. disable enable

STRING Bf0 Bf1 Bg04 Bg20 Bg60 Bg99 BQ0 BQ1 Bi01-Bi99

Page 119

HOST CONFIGURATION STRINGS

A

READING PARAMETERS DESCRIPTION Timeout Between Same Code Readings (100 ms) Single Line Decoding Duration Single Line Timeout OFF Before Raster Beeper Intensity beeper off low intensity medium intensity high intensity Beeper Tone tone 1 tone 2 tone 3 tone 4 Beeper Type monotone bitonal Beeper Length long short

STRING Bh01 - Bh99 Bd01 – Bd20 Be1 – Be9 BG0 BG1 BG2 BG3 BH0 BH1 BH2 BH3 BJ0 BJ1 BI0 BI1

DECODING PARAMETERS DESCRIPTION Ink-Spread Overflow Control Interdigit Control Code 39 Stitching Code 128 Stitching Decoding Safety disable enable disable enable disable enable disable enable disable enable one read two reads three reads four reads

STRING AX0 AX1 AW1 AW0 AV0 AV1 Aa0 Aa1 Ac0 Ac1 ED0 ED1 ED2 ED3

111

Page 120

A

PRESENTATION SCANNERS

CODE SELECTION DESCRIPTION STRING DISABLE ALL FAMILY CODES AZ0 EAN/UPC disable EAN/UPC family AA0 EAN 8/EAN 13/UPC A/UPC E without ADD ON AA1 with ADD ON AA5 with and without ADD ON AA8 Set EAN/UPC Autodiscriminate Decoding Safety ES02-ES30 EAN 8/EAN 13 without ADD ON AA3 with ADD ON 2 ONLY AAK with ADD ON 5 ONLY AAL with ADD ON 2 AND 5 AA6 UPC A/UPC E without ADD ON AA4 with ADD ON 2 ONLY AAM with ADD ON 5 ONLY AAN with ADD ON 2 AND 5 AA7 With Add On Only for Selected Prefixes disable Ad0 enable Ad1 Select Prefixes cancel all selections ET0 378/379 only ET1378ET2379 434/439 only ET3434ET4439 414/419 only ET5414ET6419 977 ET7977 978 ET8978 979 ET9979 EAN 8 check digit transmission disable AAG0 enable AAG1 EAN 13 check digit transmission disable AAH0 enable AAH1 UPC A check digit transmission disable AAI0 enable AAI1 UPC E check digit transmission disable AAJ0 enable AAJ1 conversions UPC E to UPC A AAA UPC E to EAN 13 AAB UPC A to EAN 13 AAC EAN 8 to EAN 13 AAD

112

Page 121

HOST CONFIGURATION STRINGS

CODE SELECTION (continued) DESCRIPTION ISBN Conversion codes enable ISBN enable ISSN enable ISBN and ISSN disable ISBN and ISSN Code 39 disable Code 39 family Standard no check digit control check digit control and transmission check digit control without transmission Full ASCII no check digit control check digit control and transmission check digit control without transmission CIP 39 Code 32 code length 2/5 disable Code 2/5 family Interleaved 2/5 no check digit control check digit control and transmission check digit control without transmission Normal 2/5 5 bars no check digit control check digit control and transmission check digit control without transmission Industrial 2/5 (IATA) no check digit control check digit control and transmission check digit control without transmission Matrix 2/5 3 bars no check digit control check digit control and transmission check digit control without transmission CIP/HR

A

STRING AP1 AP2 AP3 AP0 AB0 AB11 AB12 AB13 AB21 AB22 AB23 AB3 AB4 AB*xxxx AC0 AC11xxxx AC12xxxx AC13xxxx AC21xxxx AC22xxxx AC23xxxx AC31xxxx AC32xxxx AC33xxxx AC41xxxx AC42xxxx AC43xxxx AC5 xxxx = ASCII numbers that define the code length where: • •

First 2 digits = minimum acceptable code length. Second 2 digits = maximum acceptable code length.

The minimum code length must always be less than or equal to the maximum. The maximum code lengths are 99 characters. Examples: 0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only.

113

Page 122

A

PRESENTATION SCANNERS

CODE SELECTION (continued) DESCRIPTION Codabar disable Codabar family Standard no start/stop character equality control nor transmission no start/stop character equality control but transmission start/stop character equality control but no transmission start/stop character equality control and transmission code length start/stop character case in lower case transmission upper case Code 128 disable Code 128 family enable Code 128 - control without transmission of check digit enable EAN 128 - control without transmission of check digit transmit GS before disable Code enable code length Code 93 disable Code 93 family enable Code 93 - control without transmission of check digit MSI disable the family no check MOD10 no tx MOD10 with tx MOD11-MOD10 no tx MOD11-MOD10 with tx MOD10-MOD10 no tx MOD10-MOD10 with tx

STRING AD0 AD111 AD112 AD121 AD122 AD*xxxx ADA0 ADA1 AI0 AI11 AI21 EQ0 EQ1 AILxxxx AK0 AK1 AE0 AE1 AE2 AE3 AE4 AE5 AE6 AE7 xxxx = ASCII numbers that define the code length where: • First 2 digits = minimum acceptable code length. • Second 2 digits = maximum acceptable code length. The minimum code length must always be less than or equal to the maximum. The maximum code lengths are 99 characters. Examples: 0132 = variable length from 1 to 32 digits in the code. 1010 = 10 digit code length only.

114

Page 123

HOST CONFIGURATION STRINGS

A

CODE SELECTION (continued) DESCRIPTION Plessey

RSS Codes disable the family Standard no check Standard check - with tx Standard check - no tx Anker no check Anker check - with tx Anker check - no tx disable the family disable RSS Expanded Linear enable RSS Expanded Linear disable RSS Limited enable RSS Limited disable RSS 14 Linear enable RSS 14 Linear

STRING AF0 AF11 AF12 AF13 AF21 AF22 AF23 AQ0 AQ10 AQ11 AQ20 AQ21 AQ30 AQ31

115