Page 83

Enter Configuration

Ì$+;Î

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

CONCATENATION disable

ÌEI0aÎ enable

ÌEI1dÎ Permits the concatenation of two codes defined by code type and length. It is possible to set a timeout for the second code reading and to define code transmission if the timeout expires. The order of transmission is CODE 1-CODE 2.

Define Concatenation

1

Code 1 code ID

ÌEK0eÎ Read the code type from the Code Identifier Table beginning in Appendix B. code length

ÌEL0gÎ Read a number in the range 01-99 from the Hex/Numeric Table.

75

Page 84

Exit and Save Configuration

ADVANCED FORMATTING 2

Ì$-?Î

Code 2 code ID

ÌEK1hÎ Read the code type from the Code Identifier Table beginning in Appendix B. code length

ÌEL1jÎ Read a number in the range 01-99 from the Hex/Numeric Table.

3

Concatenation Result Code ID use code 1 ID

ÌEN0kÎ use code 2 ID

ÌEN1nÎ Since you can concatenate codes from different families, you must select the Code ID character of the resulting code. The Code ID character will be sent in the output message only if it is enabled according to the Code Identifier selection (Datalogic, AIM, or Custom).

4

Concatenation Timeout timeout

ÌEJ3Î Read two numbers in the range 00 to 99 00= no timeout 01-99 = timeout from 1 to 99 seconds Define the timeout, which determines the valid waiting period between the two codes, in order to accept concatenation. If the timeout expires, the resulting action will be based on the following selection.

76

Page 85

Exit and Save Configuration

ADVANCED FORMATTING 5

Ì$-?Î

Transmission after Timeout no code transmitted after timeout

ÌEM0iÎ only code 1 transmitted (if read) after timeout

ÌEM1lÎ only code 2 transmitted (if read) after timeout

ÌEM2oÎ either code 1 or code 2 transmitted after timeout

ÌEM3rÎ

77

Page 86

ADVANCED FORMATTING ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of barcode data before transmitting it to the host system. This formatting will be performed when the barcode data meets certain criteria which you will define in the following procedure. Up to 4 advanced code management formats can be defined and saved in memory. For each format you must complete the entire configuration procedure: Read the Enter Configuration Command Step 1 Begin Format Definition 1, 2, 3, or 4 Steps 2 - 4 Define Match Code Conditions Step 5 Divide Code into Fields Step 6 Define Code Fields Steps 7 - 8 Add up to 2 Additional Fields Step 9 Define Field Transmission Step 10 Apply or Not Standard Message Formatting Step 11 End Format Definition 1, 2, 3, or 4 YES

Define another? NO

Enable Advanced Formats 1, 2, 3, 4 Define No Match Result Read the Exit and Save Configuration Command

78

Page 87

Enter Configuration

Ì$+;Î 1

Exit and Save Configuration

ADVANCED FORMATTING

Ì$-?Î

Begin Format Definition begin Format 1 definition

ÌHA0TÎ begin Format 2 definition

ÌHA1WÎ begin Format 3 definition

ÌHA2ZÎ begin Format 4 definition

ÌHA3]Î 2

Match Code Type match code type

ÌHB&Î Read the above code + the code type to match from the Code Identifier Table in Appendix B. OR any code type

ÌHB0VÎ 3

Match Code Length match code length

ÌHC(Î Read the above code + two numbers in the range 01 to 99 for the exact code length. OR any code length

ÌHC001Î 79

Page 88

Exit and Save Configuration

ADVANCED FORMATTING 4

Ì$-?Î

Match with Predefined Characters no match

ÌHD0HE00ÄÎ OR match with 1 character

ÌHD1]Î match with a 2-character string

ÌHD2`Î match with a 3-character string

ÌHD3cÎ match with a 4-character string

ÌHD4fÎ After selecting the predefined match code, read the character(s) from the HEX table. Range of characters = 01-FE. Example: Match code with the 2-character predefined string = "@@". Match with a 2-character string

Read

AND

+ 40 + 40 position of first character in predefined string

ÌHE,Î Read the above code + two numbers in the range 01 to 99 representing the character position in the code where the first character of the predefined string must be found. Read 00 if the match string can be found in any character position.

80

Page 89

Exit and Save Configuration

ADVANCED FORMATTING 5

Ì$-?Î

Divide Code into Fields divide code into fields

ÌHF.Î Read one number in the range 1 to 5 to divide the code into fields.

6

Define Code Fields define code fields

Each code field length can be set by either: a) defining a field separator character to be found in the code itself. In this case you can choose to discard the code separator character or include it as the last character of the field. OR BY b) defining a match character to be found consecutively repeated in the code itself. In this case the field ends with the first character that does not match. OR BY c) specifying a specific character length up to the maximum of 99 characters. OR BY d) selecting the last field as variable length (if any).

You must define the same number of fields as selected in step 5, including fields that will not be transmitted.

81

Page 90

Exit and Save Configuration

Ì$-?Î

ADVANCED FORMATTING DEFINE FIELD 1 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator

Ì01Î

Ì12Î OR match character

ÌHG3iÎ b)

Read the match character from the HEX table. Range of characters = 01-FE. OR field length

ÌHG1cÎ c)

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

ÌHG2fÎ d)

AND Field 1 Terminators no field terminators

ÌHH0bÎ 1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character.

82

Page 91

Exit and Save Configuration

Ì$-?Î

ADVANCED FORMATTING DEFINE FIELD 2 BY: EITHER field separator

ÌHG0`Î a)

Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator

Ì01Î

Ì12Î OR match character

ÌHG3iÎ b)

Read the match character from the HEX table. Range of characters = 01-FE. OR field length

ÌHG1cÎ c)

Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)

ÌHG2fÎ d)

AND Field 2 Terminators no field terminators

ÌHH0bÎ 1 field terminator

2 field terminators

ÌHH1eÎ

ÌHH2hÎ

Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character.