The text of a manual · part 12 of 16
Presentation Scanners Software Configuration Manual: CONFIGURATION, pages 83 to 91
Pages 83 to 91 of 128, from Presentation Scanners Software Configuration Manual
The original document is the PDF (3.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
Filed in the catalog under the Datalogic Catcher D531
Page 83
Enter Configuration
Ì$+;Î
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
CONCATENATION disable
ÌEI0aÎ enable
ÌEI1dÎ Permits the concatenation of two codes defined by code type and length. It is possible to set a timeout for the second code reading and to define code transmission if the timeout expires. The order of transmission is CODE 1-CODE 2.
Define Concatenation
1
Code 1 code ID
ÌEK0eÎ Read the code type from the Code Identifier Table beginning in Appendix B. code length
ÌEL0gÎ Read a number in the range 01-99 from the Hex/Numeric Table.
75
Page 84
Exit and Save Configuration
ADVANCED FORMATTING 2
Ì$-?Î
Code 2 code ID
ÌEK1hÎ Read the code type from the Code Identifier Table beginning in Appendix B. code length
ÌEL1jÎ Read a number in the range 01-99 from the Hex/Numeric Table.
3
Concatenation Result Code ID use code 1 ID
ÌEN0kÎ use code 2 ID
ÌEN1nÎ Since you can concatenate codes from different families, you must select the Code ID character of the resulting code. The Code ID character will be sent in the output message only if it is enabled according to the Code Identifier selection (Datalogic, AIM, or Custom).
4
Concatenation Timeout timeout
ÌEJ3Î Read two numbers in the range 00 to 99 00= no timeout 01-99 = timeout from 1 to 99 seconds Define the timeout, which determines the valid waiting period between the two codes, in order to accept concatenation. If the timeout expires, the resulting action will be based on the following selection.
76
Page 85
Exit and Save Configuration
ADVANCED FORMATTING 5
Ì$-?Î
Transmission after Timeout no code transmitted after timeout
ÌEM0iÎ only code 1 transmitted (if read) after timeout
ÌEM1lÎ only code 2 transmitted (if read) after timeout
ÌEM2oÎ either code 1 or code 2 transmitted after timeout
ÌEM3rÎ
77
Page 86
ADVANCED FORMATTING ADVANCED FORMATTING Advanced formatting has been designed to offer you complete flexibility in changing the format of barcode data before transmitting it to the host system. This formatting will be performed when the barcode data meets certain criteria which you will define in the following procedure. Up to 4 advanced code management formats can be defined and saved in memory. For each format you must complete the entire configuration procedure: Read the Enter Configuration Command Step 1 Begin Format Definition 1, 2, 3, or 4 Steps 2 - 4 Define Match Code Conditions Step 5 Divide Code into Fields Step 6 Define Code Fields Steps 7 - 8 Add up to 2 Additional Fields Step 9 Define Field Transmission Step 10 Apply or Not Standard Message Formatting Step 11 End Format Definition 1, 2, 3, or 4 YES
Define another? NO
Enable Advanced Formats 1, 2, 3, 4 Define No Match Result Read the Exit and Save Configuration Command
78
Page 87
Enter Configuration
Ì$+;Î 1
Exit and Save Configuration
ADVANCED FORMATTING
Ì$-?Î
Begin Format Definition begin Format 1 definition
ÌHA0TÎ begin Format 2 definition
ÌHA1WÎ begin Format 3 definition
ÌHA2ZÎ begin Format 4 definition
ÌHA3]Î 2
Match Code Type match code type
ÌHB&Î Read the above code + the code type to match from the Code Identifier Table in Appendix B. OR any code type
ÌHB0VÎ 3
Match Code Length match code length
ÌHC(Î Read the above code + two numbers in the range 01 to 99 for the exact code length. OR any code length
ÌHC001Î 79
Page 88
Exit and Save Configuration
ADVANCED FORMATTING 4
Ì$-?Î
Match with Predefined Characters no match
ÌHD0HE00ÄÎ OR match with 1 character
ÌHD1]Î match with a 2-character string
ÌHD2`Î match with a 3-character string
ÌHD3cÎ match with a 4-character string
ÌHD4fÎ After selecting the predefined match code, read the character(s) from the HEX table. Range of characters = 01-FE. Example: Match code with the 2-character predefined string = "@@". Match with a 2-character string
Read
AND
+ 40 + 40 position of first character in predefined string
ÌHE,Î Read the above code + two numbers in the range 01 to 99 representing the character position in the code where the first character of the predefined string must be found. Read 00 if the match string can be found in any character position.
80
Page 89
Exit and Save Configuration
ADVANCED FORMATTING 5
Ì$-?Î
Divide Code into Fields divide code into fields
ÌHF.Î Read one number in the range 1 to 5 to divide the code into fields.
6
Define Code Fields define code fields
Each code field length can be set by either: a) defining a field separator character to be found in the code itself. In this case you can choose to discard the code separator character or include it as the last character of the field. OR BY b) defining a match character to be found consecutively repeated in the code itself. In this case the field ends with the first character that does not match. OR BY c) specifying a specific character length up to the maximum of 99 characters. OR BY d) selecting the last field as variable length (if any).
You must define the same number of fields as selected in step 5, including fields that will not be transmitted.
81
Page 90
Exit and Save Configuration
Ì$-?Î
ADVANCED FORMATTING DEFINE FIELD 1 BY: EITHER field separator
ÌHG0`Î a)
Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator
Ì01Î
Ì12Î OR match character
ÌHG3iÎ b)
Read the match character from the HEX table. Range of characters = 01-FE. OR field length
ÌHG1cÎ c)
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
ÌHG2fÎ d)
AND Field 1 Terminators no field terminators
ÌHH0bÎ 1 field terminator
2 field terminators
ÌHH1eÎ
ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character.
82
Page 91
Exit and Save Configuration
Ì$-?Î
ADVANCED FORMATTING DEFINE FIELD 2 BY: EITHER field separator
ÌHG0`Î a)
Read the field separator character from the HEX table. Range of characters = 01-FE. discard separator include separator
Ì01Î
Ì12Î OR match character
ÌHG3iÎ b)
Read the match character from the HEX table. Range of characters = 01-FE. OR field length
ÌHG1cÎ c)
Read two numbers in the range 01 to 99 to define the field length. OR this is the last field (variable length)
ÌHG2fÎ d)
AND Field 2 Terminators no field terminators
ÌHH0bÎ 1 field terminator
2 field terminators
ÌHH1eÎ
ÌHH2hÎ
Read the field terminator character(s) from the HEX table. Valid range of characters for all readers = 01-FE. For readers using Wedge interface, all values from 9C to FE send the Space character.
83