Page 74
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
The pharmaceutical codes below are part of the Code 39 family but have no check digit selections.
Code CIP39
ÌAB3XÎ French pharmaceutical code
Code 32
ÌAB4[Î Italian pharmaceutical code
CODE LENGTH (optional) The code length selection is valid for the entire Code 39 family Read the code + 4 numbers for the code length where:
set code length
First 2 digits = minimum code length. Second 2 digits = maximum code length.
ÌAB*=Î
The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only. Default character range: 04-99
66
Page 75
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
CODE 128 FAMILY disables the family
ÌAI0]Î Read the desired family code Code 128
ÌAI11=Î control without transmission of check digit
EAN 128
ÌAI21@Î control without transmission of check digit
Transmit GS Before Code Code EAN 128 uses the ASCII <GS> character to separate a variable length code field from the next code field. This character can also be transmitted before the code. disable
ÌEQ0qÎ enable
ÌEQ1tÎ If the <GS> character has been modified in the Character Replacement parameter, the new character is affected by this command.
67
Page 76
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
CODE LENGTH (optional) The code length selection is valid for the entire Code 128 family. Read the code + 4 numbers for the code length where:
set code length
First 2 digits = minimum code length
ÌAILJÎ
Second 2 digits = maximum code length
The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples:
0199 = variable from 1 to 99 digits in the code. 1010= 10 digit code length only.
Default character range: 01-99 The length is calculated on the output string.
CODE 93 disables the code
ÌAK0aÎ
Code 93
ÌAK1dÎ control without transmission of check digit
68
Page 77
Enter Configuration
Ì$+;Î
Exit and Save Configuration
Ì$-?Î
CODE SELECTION CODABAR FAMILY disables the family
ÌAD0SÎ Read the desired equality control code
Read a start/stop transmission selection START/STOP CHARACTER TRANSMISSION
Standard Codabar
ÌAD113Î no start/stop character equality control no transmission
Ì12Î Standard Codabar
ÌAD127Î start/stop character equality control transmission
Ì23Î CODE LENGTH (optional) The code length selection is valid for the entire Codabar family Read the code + 4 numbers for the code length where:
set code length
First 2 digits = minimum code length. Second 2 digits = maximum code length.
ÌAD*AÎ
The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only.
69
Page 78
Enter Configuration
Exit and Save Configuration
Ì$+;Î
CODE SELECTION
Ì$-?Î
START/STOP CHARACTER CASE IN TRANSMISSION
The start/stop character case selections below are valid for the entire Codabar family:
transmit start/stop characters in lower case
ÌADA0_Î transmit start/stop characters in upper case
ÌADA1cÎ
70
Page 79
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
MSI disables the family
ÌAE0UÎ Enable the code by selecting one of the check digit selections. no check digit control
ÌAE1XÎ MOD10 check digit control no check digit transmission
ÌAE2[Î MOD10 check digit control check digit transmission
ÌAE3^Î MOD11 - MOD10 check digit control no check digit transmission
ÌAE4aÎ MOD11 - MOD10 check digit control check digit transmission
ÌAE5dÎ MOD10 - MOD10 check digit control no check digit transmission
ÌAE6gÎ MOD10 - MOD10 check digit control check digit transmission
ÌAE7jÎ 71
Page 80
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
PLESSEY disables the family
ÌAF0WÎ Enable the code by selecting one of the check digit selections.
Standard Plessey no check digit control
ÌAF117Î check digit control check digit transmitted
ÌAF12;Î check digit control check digit not transmitted
ÌAF13?Î Anker Plessey no check digit control
ÌAF21:Î check digit control check digit transmitted
ÌAF22>Î check digit control check digit not transmitted
ÌAF23BÎ
72
Page 81
Enter Configuration
Ì$+;Î
Exit and Save Configuration
CODE SELECTION
Ì$-?Î
RSS CODES disables the family
ÌAQ0mÎ DISABLE CODE ENABLE CODE disable RSS Expanded Linear
ÌAQ10IÎ enable RSS Expanded Linear
ÌAQ11MÎ disable RSS Limited
ÌAQ20LÎ enable RSS Limited
ÌAQ21PÎ disable RSS 14 Linear
ÌAQ30OÎ enable RSS 14 Linear
ÌAQ31SÎ
73
Page 82
ADVANCED FORMATTING
CONCATENATION ADVANCED FORMATTING
Please follow the setup procedure carefully for these parameters. NOTE
1. 2.
Read the Enter Configuration code ONCE, available at the top of page . Read configuration codes precisely following the numbered procedure given. = Read the code and follow the procedure given = Default value
3.
74
Read the Exit and Save Configuration code ONCE, available at the top of page.