Page 74

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

The pharmaceutical codes below are part of the Code 39 family but have no check digit selections.

Code CIP39

ÌAB3XÎ French pharmaceutical code

Code 32

ÌAB4[Î Italian pharmaceutical code

CODE LENGTH (optional) The code length selection is valid for the entire Code 39 family Read the code + 4 numbers for the code length where:

set code length

First 2 digits = minimum code length. Second 2 digits = maximum code length.

ÌAB*=Î

The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only. Default character range: 04-99

66

Page 75

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

CODE 128 FAMILY disables the family

ÌAI0]Î Read the desired family code Code 128

ÌAI11=Î control without transmission of check digit

EAN 128

ÌAI21@Î control without transmission of check digit

Transmit GS Before Code Code EAN 128 uses the ASCII <GS> character to separate a variable length code field from the next code field. This character can also be transmitted before the code. disable

ÌEQ0qÎ enable

ÌEQ1tÎ If the <GS> character has been modified in the Character Replacement parameter, the new character is affected by this command.

67

Page 76

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

CODE LENGTH (optional) The code length selection is valid for the entire Code 128 family. Read the code + 4 numbers for the code length where:

set code length

First 2 digits = minimum code length

ÌAILJÎ

Second 2 digits = maximum code length

The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples:

0199 = variable from 1 to 99 digits in the code. 1010= 10 digit code length only.

Default character range: 01-99 The length is calculated on the output string.

CODE 93 disables the code

ÌAK0aÎ

Code 93

ÌAK1dÎ control without transmission of check digit

68

Page 77

Enter Configuration

Ì$+;Î

Exit and Save Configuration

Ì$-?Î

CODE SELECTION CODABAR FAMILY disables the family

ÌAD0SÎ Read the desired equality control code

Read a start/stop transmission selection START/STOP CHARACTER TRANSMISSION

Standard Codabar

ÌAD113Î no start/stop character equality control no transmission

Ì12Î Standard Codabar

ÌAD127Î start/stop character equality control transmission

Ì23Î CODE LENGTH (optional) The code length selection is valid for the entire Codabar family Read the code + 4 numbers for the code length where:

set code length

First 2 digits = minimum code length. Second 2 digits = maximum code length.

ÌAD*AÎ

The maximum code length is 99 characters. The minimum code length must always be less than or equal to the maximum. Examples: 0199 = variable from 1 to 99 digits in the code. 1010 = 10 digit code length only.

69

Page 78

Enter Configuration

Exit and Save Configuration

Ì$+;Î

CODE SELECTION

Ì$-?Î

START/STOP CHARACTER CASE IN TRANSMISSION

The start/stop character case selections below are valid for the entire Codabar family:

transmit start/stop characters in lower case

ÌADA0_Î transmit start/stop characters in upper case

ÌADA1cÎ

70

Page 79

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

MSI disables the family

ÌAE0UÎ Enable the code by selecting one of the check digit selections. no check digit control

ÌAE1XÎ MOD10 check digit control no check digit transmission

ÌAE2[Î MOD10 check digit control check digit transmission

ÌAE3^Î MOD11 - MOD10 check digit control no check digit transmission

ÌAE4aÎ MOD11 - MOD10 check digit control check digit transmission

ÌAE5dÎ MOD10 - MOD10 check digit control no check digit transmission

ÌAE6gÎ MOD10 - MOD10 check digit control check digit transmission

ÌAE7jÎ 71

Page 80

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

PLESSEY disables the family

ÌAF0WÎ Enable the code by selecting one of the check digit selections.

Standard Plessey no check digit control

ÌAF117Î check digit control check digit transmitted

ÌAF12;Î check digit control check digit not transmitted

ÌAF13?Î Anker Plessey no check digit control

ÌAF21:Î check digit control check digit transmitted

ÌAF22>Î check digit control check digit not transmitted

ÌAF23BÎ

72

Page 81

Enter Configuration

Ì$+;Î

Exit and Save Configuration

CODE SELECTION

Ì$-?Î

RSS CODES disables the family

ÌAQ0mÎ DISABLE CODE ENABLE CODE disable RSS Expanded Linear

ÌAQ10IÎ enable RSS Expanded Linear

ÌAQ11MÎ disable RSS Limited

ÌAQ20LÎ enable RSS Limited

ÌAQ21PÎ disable RSS 14 Linear

ÌAQ30OÎ enable RSS 14 Linear

ÌAQ31SÎ

73

Page 82

ADVANCED FORMATTING

CONCATENATION ADVANCED FORMATTING

Please follow the setup procedure carefully for these parameters. NOTE

1. 2.

Read the Enter Configuration code ONCE, available at the top of page . Read configuration codes precisely following the numbered procedure given. = Read the code and follow the procedure given = Default value

3.

74

Read the Exit and Save Configuration code ONCE, available at the top of page.