Page 8
CONFIGURATION METHODS Reading Configuration Barcodes If you wish to change the default settings, this manual provides complete configuration of your scanner in an easy way: To configure your scanner:
1) Read the Enter Configuration code ONCE, available at the top of each page of configuration.
2) Modify the desired parameters in one or more sections following the procedures given for each group. Some configuration codes require reading hex or numeric codes from the table in Appendix C.
3) Read the Exit and Save Configuration code ONCE, available at the top of each page of configuration. Reference notes describing the operation of the more complex parameters are given in chapter 4.
Using DL Sm@rtSet DL Sm@rtSet is a Windows-based utility program providing a quick and user-friendly configuration method via the RS232 or USB-COM interfaces. It also allows upgrading the software of the connected device (see the DL Sm@rtSet User’s Manual for more details).
Copy Command A previously configured scanner (Master device), can be used to send its configuration directly to other scanners of the same type. The particular procedure for each device is given in par. 4.9.
Sending Configuration Strings from Host An alternative configuration method is provided in Appendix A using the RS232 or USB interfaces. This method is particularly useful when many devices need to be configured with the same settings. Batch files containing the desired parameter settings can be prepared to configure devices quickly and easily.
vi
Page 9
INTRODUCTION
1
1
INTRODUCTION
This manual provides all the necessary information for complete software configuration of various Presentation Scanner families. Your scanner contains a built-in decoder and multi-standard interface. It is designed for use in a wide variety of applications and environments including commercial, office automation and retail applications where large quantities of information need to be collected rapidly, easily and reliably. It has several status indicator functions which are described in the next paragraph.
1.1
STATUS INDICATORS
Several status indicators are available. They signal several operating conditions which are described in the tables below. H = high tone
L = low tone
SCANNER START-UP Beeper
1
Meaning
LLLL
Parameters loaded correctly or when exiting sleep mode (wakeup).
H H H H long tones
Parameter loading error, reading or writing error in the non volatile memory
HLHL
Hardware error in EEPROM
SCANNER CONFIGURATION Beeper
1
HHHH L LLL LHHHH 1
Meaning correct entry in Configuration mode good read of a command command read error exit from Configuration mode only the Beeper Intensity command can modify these signals.
1
Page 10
PRESENTATION SCANNERS
1 H = high tone
L = low tone
SCANNER DATA ENTRY Beeper one beep2
L H1
LED Green constant
Meaning
Correct read of a code in normal mode. It remains constant once the decoding process has been successfully completed and the scanner is in Timeout between same code readings.
Red constant
It is constant in normal mode while the Laser is ON and the scanner is ready to read a new code (not in Timeout between same code readings).
Red constant
No read in single line mode after Single Line Decoding Duration timeout.
Red blinking fast
It blinks fast when the scanner is in Stand-by mode
Red blinking slow
It blinks slower when the scanner is in Sleep mode
Green/Red blinking alternatively
They turn configuration on alternatively during serial
1 only the Beeper Intensity command can modify these signals.
2 the data entry good read tone is user-configurable with all the Beeper commands in the Reading Parameter section.
2