Page 11

INITIAL SETUP

2

INITIAL SETUP

2.1

SINGLE LINE MODE

2

When many barcodes are present in the same reading area, like in barcode price lists or in the case of configuration barcodes in this manual, selecting a specific barcode to read is not practical with the large raster pattern emitted by the presentation scanner, so a special single line scanning mode can be easily entered to perform this task. In this mode only a single scanning line is enabled so that aiming and reading barcodes becomes very easy. To use single line mode for barcode reading follow the procedure below: 1.

While the normal raster pattern is present, press the trigger. A single laser line will appear but barcodes cannot be decoded.

2.

Position the presentation scanner over the code to read and press the trigger within 5 seconds to decode the code.

When using the scanner for data entry, a programmable timeout is provided to assure that the presentation scanner will return to raster mode if barcode reading is not successful in single line (Single Line Decoding Duration). Also a programmable timeout is available to manage how long to wait after successful reading before returning to raster mode (Single Line Timeout OFF Before Raster). If you need to make consecutive readings in single line mode, simply repeat the procedure before the Single Line Timeout OFF Before Raster expires. When in configuration, the scanner will remain in single line until the Exit Configuration barcode is read. Single Line and Wakeup Trigger Good Read LED

3

Page 12

PRESENTATION SCANNERS

2

2.2

INTERFACE SELECTION

Follow the procedure to configure the interface required by your application • • •

USB Interface RS232 Interface Wedge Interface

2.2.1

USB Interface Configuration

The USB interface is compatible with: -

Windows 98 (and later) Mac OS 8.0 (and later) IBM POS for Windows 4690 Operating System

START-UP As with all USB devices, upon connection, the Host performs several checks by communicating with the presentation scanner. During this phase the green LED on the scanner blinks and normal operations are suspended. Two basic conditions must be met before the presentation scanner is ready to read codes, the correct USB driver must be loaded and sufficient power must be supplied to the reader. For all systems, the correct USB driver for the default USB-KBD interface is included in the Host Operating System and will either be loaded automatically or will be suggested by the O.S. and should therefore be selected from the dialog box (the first time only). If the Host supplies sufficient power to the reader, the start-up phase ends correctly, the green LED stops blinking and the reader emits the beep OK signal. If the Host does not supply sufficient power to the reader, a dialog box will appear on the Host and the reader will be blocked (green LED continues blinking). In this case, disconnect the USB cable at the Host (green LED stops blinking), connect and power-up an external supply to the USB cable then reconnect the USB cable to the Host and close the dialog box. The reader emits the beep OK signal. You can now read codes. At this point you can read the USB interface configuration code according to your application. Load drivers from the O.S. (if requested). When configuring the USB-COM interface, the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web page http://www.datalogic.com. The presentation scanner is ready.

4

Page 13

INITIAL SETUP

2 First Start-Up Connect the presentation scanner to Host

Green LED blinks

Load drivers (if requested)

Green LED off

Disconnect the presentation scanner at Host

YES

Connect external power supply to cable and power up

BEEP OK

Does a dialog box appear warning that Bus power is not sufficient? NO Green LED off - BEEP OK Select desired USB interface code (USB-KBD is default)

Reconnect scanner cable to Host and close dialog box

Load drivers (if requested) Read test codes. The presentation scanner is READY

Successive start-ups will automatically recognize the previously loaded drivers. If external power is used, verify that external power is already supplied.

Successive Start-Ups Connect the presentation scanner to Host

Disconnect the presentation scanner at Host

Connect external power supply to cable and power up

YES

Green LED blinks

Does a dialog box appear warning that Bus power is not sufficient? NO

Green LED off - BEEP OK BEEP OK

Reconnect scanner cable to Host and close dialog box

Read test codes. The presentation scanner is READY

5

Page 14

PRESENTATION SCANNERS

2 USB INTERFACE USB-KBD

Ì$+UA03$-:Î

USB-KBD-ALT-MODE

Ì$+UA04$-@Î

USB-KBD-APPLE

Ì$+UA05$-FÎ

USB-COM*

Ì$+UA02$-4Î

USB-IBM-Table Top

Ì$+UA00$-(Î

USB-IBM-Hand Held

Ì$+UA01$-.Î *

6

When configuring USB-COM, the relevant files and drivers must be installed from the USB Device Installation software which can be downloaded from the web page (see http://www.datalogic.com).

Page 15

INITIAL SETUP

2.2.2

2

RS232 Interface Selection

Using Single Line Mode read the restore default code, then read the interface selection code for your application: Restore Default

Ì$+$*oÎ RS232 INTERFACE Standard

Ì$+CP0$-$Î

POS SYSTEMS Nixdorf Mode A

Ì$+CM2EC0$->Î

Fujitsu

Ì$+CM1$-ÈÎ

ICL Mode

Ì$+CM0$-ÃÎ For POS system default settings refer to par. 4.11

7

Page 16

PRESENTATION SCANNERS

2

2.2.3

Wedge Interface Selection

Using Single Line Mode read the restore default code, then read the interface selection code for your application: Restore Default

Ì$+$*oÎ WEDGE INTERFACE IBM AT or PS/2 PCs

Ì$+CP500$-aÎ IBM XT

Ì$+CP503$-vÎ PC Notebook

Ì$+CP505$-ÈÎ IBM SURE1

Ì$+CP506$-$Î IBM Terminal 3153

Ì$+CP504$-}Î

8

Page 17

INITIAL SETUP

2 WEDGE INTERFACE (CONTINUED) IBM Terminals 31xx, 32xx, 34xx, 37xx:

To select the interface for these IBM Terminals, read the correct KEY TRANSMISSION code. Select the KEYBOARD TYPE if necessary (default = advanced keyboard). KEY TRANSMISSION MODE make-only keyboard

Ì$+CP502$-oÎ make-break keyboard

Ì$+CP501$-hÎ KEYBOARD TYPE advanced keyboard

Ì$+FK1$-ÉÎ typewriter keyboard

Ì$+FK0$-ÄÎ ALT MODE The following interface selection allows barcodes sent to the PC to be interpreted correctly independently from the Keyboard Nationality used. You do not need to make a Keyboard Nationality selection. (default = Num Lock Unchanged). Make sure the Num Lock key on your keyboard is ON. IBM AT - ALT mode

Ì$+CP507$-+Î PC Notebook - ALT mode

Ì$+CP508$-2Î 9

Page 18

PRESENTATION SCANNERS

2

WEDGE INTERFACE (CONTINUED) WYSE TERMINALS ANSI Keyboard

Ì$+CP509$-9Î PC Keyboard

Ì$+CP510$-gÎ ASCII Keyboard

Ì$+CP511$-nÎ VT220 style Keyboard

Ì$+CP514$-ÇÎ

DIGITAL TERMINALS VT2xx/VT3xx/VT4xx

Ì$+CP512$-uÎ

APPLE (NOT AVAILABLE FOR DIAMOND™ D531) APPLE ADB Bus

Ì$+CP513$-|Î

10

Page 19

INITIAL SETUP

2.2.4

2

IBM 46xx Interface Selection (IBM Devices only) PORT 9B 4501 Protocol

Ì$+CP800$-pÎ (typical)

1520 Protocol

Ì$+CP801$-wÎ

PORT 5B 1520 Protocol

Ì$+CP801$-wÎ (typical)

4501 Protocol

Ì$+CP800$-pÎ

11