Page 20
PRESENTATION SCANNERS
3
3
CONFIGURATION
Once your scanner is setup, you can change the default parameters to meet your application needs. Refer to chapter 2 for initial configuration in order to set the default values and select the interface for your application. In this manual, the configuration parameters are divided into logical groups making it easy to find the desired function based on its reference group. The first three groups are for Standard Interface parameter configuration, the fourth is only for IBM 46xx models: •
RS232
•
USB
•
WEDGE
•
IBM
The following parameter groups are common to all interface applications: DATA FORMAT parameters regard the messages sent to the Host system. POWER SAVE manages overall current consumption in the reading device. READING PARAMETERS control various operating modes and indicator status functioning. DECODING PARAMETERS maintain correct barcode decoding in certain special reading conditions. CODE SELECTION parameters allow configuration of a personalized mix of codes, code families and their options. ADVANCED FORMATTING PARAMETERS allow advanced formatting of messages towards the Host.
12 code concatenation and
Page 21
RS232 PARAMETERS BAUD RATE PARITY DATA BITS STOP BITS HANDSHAKING ACK/NACK PROTOCOL INTER-CHARACTER DELAY RX TIMEOUT SERIAL DECODE CONTROL SERIAL SLEEP CONTROL
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given = Default value
3.
Read the Exit and Save Configuration code ONCE, available at the top of each page.
13
Page 22
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RS232
Ì$-?Î
BAUD RATE
300 baud
ÌCD1XÎ 600 baud
ÌCD2[Î 1200 baud
ÌCD3^Î 2400 baud
ÌCD4aÎ 4800 baud
ÌCD5dÎ 9600 baud
ÌCD6gÎ 19200 baud
ÌCD7jÎ 38400 baud
ÌCD8mÎ
14
Page 23
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RS232
Ì$-?Î
PARITY none
ÌCC0SÎ even parity
ÌCC1VÎ odd parity
ÌCC2YÎ DATA BITS 7 bits
ÌCA0OÎ
8 bits
ÌCA1RÎ
15
Page 24
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RS232 STOP BITS 1 stop bit
ÌCB0QÎ
2 stop bits
ÌCB1TÎ HANDSHAKING disable
ÌCE0WÎ hardware (RTS/CTS)
ÌCE1ZÎ software (XON/XOFF)
ÌCE2]Î
RTS always ON
ÌCE3`Î See par. 4.1.1 for details.
16
Ì$-?Î
Page 25
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RS232
Ì$-?Î
ACK/NACK PROTOCOL disable
ÌER0sÎ enable
ÌER1vÎ See par. 4.1.2 for details.
INTER-CHARACTER DELAY delay between characters transmitted to Host
ÌCK3Î Read 2 numbers from the table where: 00 = DELAY disabled 01-99 = DELAY from 1 to 99 milliseconds delay disabled
17
Page 26
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RS232
Ì$-?Î
RX TIMEOUT timeout control in reception from Host
ÌCL5Î Read 2 numbers from the table where: 00 = TIMEOUT disabled 01-99 = TIMEOUT from .1 to 9.9 seconds rx timeout 5 seconds
See par. 4.1.3 for details.
SERIAL DECODE CONTROL disable
ÌCR0qÎ enable and select characters
ÌCR1tÎ Read 2 characters from the Hex/Numeric table in the range 00-FE where: − −
First Character enables decoding Second Character inhibits decoding until the first character is received again. See par. 4.1.4 for details.
18
Page 27
Enter Configuration
Ì$+;Î
Exit and Save Configuration
RS232
Ì$-?Î
SERIAL SLEEP CONTROL disable
ÌCS0sÎ enable and select characters
ÌCS1vÎ Read 2 characters from the Hex/Numeric table in the range 00-FE where: − −
First Character immediately puts the scanner in sleep. Second Character immediately wakesup the scanner. See par. 4.1.5 for details.
19
Page 28
USB PARAMETERS USB-COM Handshaking, Ack/Nack Protocol, Intercharacter Delay, Rx Timeout, Serial Decode Control, Serial Sleep Control
USB-KBD Keyboard Nationality, Inter-character Delay, Inter-code Delay, Control Character Emulation
USB-IBM No parameter selection required.
1.
Read the Enter Configuration code ONCE, available at the top of each page.
2.
Read configuration codes from the desired groups. = Read the code and follow the procedure given = Default value
3.
20
Read the Exit and Save Configuration code ONCE, available at the top of each page.