Page 1 of Bulletin 2755 Hand-Held Scanner with RS-232 Option User Manual

Manual · Allen-Bradley

Bulletin 2755 Hand-Held Scanner with RS-232 Option User Manual

Manual104 pagesPDF 662 KB

User manual for the Allen-Bradley 2755-G3-D and 2755-G6-D hand-held laser scanners with RS-232 option: setup, parameters, commands, specs.

Download the PDF662 KB

Names · 1 model

The models it names

Filed with · 1 model

Also filed with these models on the old site

Summary

What is in it

The Allen-Bradley user manual for the Bulletin 2755 hand-held scanner with RS-232 option, catalog numbers 2755-G3-D (standard range) and 2755-G6-D (long range). It explains the scanner's hand-held and Autosense operating modes, LED indicators, scanning ranges and troubleshooting, how to connect it to an RS-232 host and power supply, and how to set general, serial communication, message format and symbology parameters by scanning bar codes. It also covers serial commands, specifications, interface cable pinouts and maintenance.

Its parts

  1. Using this Manual
  2. Overview of Scanner
  3. Using the Scanner
  4. Setup Instructions
  5. General Setup Parameters
  6. Serial Communication Parameters
  7. Message Format Parameters
  8. Symbologies
  9. Serial Commands
  10. Specifications

From the manual

Key facts from this manual

Each line names its page in the PDF.

User manual for the Allen-Bradley Bulletin 2755 hand-held laser scanners with the RS-232 option, catalog numbers 2755-G3-D (standard range) and 2755-G6-D (long range). It shows how to connect the scanner to a serial host, set baud rate, data format, flow control and message format by scanning labels, and program it with serial commands.

Read for this summary: pages 1 to 2, 8 to 16, 25 to 34, 43 to 53, 79 to 84 and 89 to 90 of 104.

Device
Hand-held laser bar code scanner that sends decoded data to RS-232 serial ports of computers and terminals p. 11
Interface cables
2755-NCR1: RS-232 DCE, female 25-pin, 8 foot coiled, for IBM PC compatibles; 2755-NCR2: RS-232 DTE, male 25-pin, 8 foot coiled p. 16
Power supply
External 2755-PW1, plugged into the cable's 25-pin connector p. 28
Baud rates
300, 600, 1200, 2400, 4800, 9600 (default) or 19200 p. 43, 44
Data format
7 or 8 data bits, 1 or 2 stop bits, odd, even, mark, space or no parity p. 45, 46, 47, 48
Flow control
None, XON/XOFF, CTS or RTS p. 49
Symbologies
Code 39, Interleaved 2 of 5, Standard 2 of 5, Codabar, UPC, EAN/JAN, Code 128 p. 14
Operating modes
Hand-held with the trigger, or hands-free Autosense in the optional 2755-NS2 Autostand p. 12
Serial commands
STX ESC, two command letters, optional parameters, ETX; answered with ACK (06H) or NAK (15H) p. 79, 81
Transmit buffer
64 byte buffer; full, one label or no buffering p. 53
Intercharacter delay
None by default, up to 31 milliseconds p. 52
External trigger
The CTS input doubles as an external trigger input p. 89
Setup labels
Code 128 Character Set B; no separate configuration mode; two short-high beeps confirm p. 29
In the box
Scanner, scanner holder, user manual p. 8

What this manual walks you through

  • Connecting the scanner to the host's serial port p. 25, 26
  • Installing the external power supply p. 28
  • Removing the interface cable with a paper clip p. 27
  • Setting parameters by scanning menu labels p. 29, 30
  • Resetting the scanner to factory defaults p. 34
  • Setting baud rate, data bits, stop bits and parity p. 44, 45, 46, 47, 48
  • Choosing XON/XOFF, CTS or RTS flow control p. 49, 50, 51
  • Choosing serial transmit buffering p. 53

Good to know

  • Turn the host off before connecting or removing the scanner cable, or the scanner may be damaged. p. 26, 27
  • Do not mix serial programming with scanning menu labels; the firmware does not resolve conflicts. p. 80
  • CTS protocol cannot be used when external triggering is enabled. p. 49
  • A computer with a 9-pin port may need an adapter. p. 26
  • The host should pause after changing communication settings, since the scanner takes about one second to save them. p. 82

Questions this manual answers

What cable connects an Allen-Bradley 2755-G3-D scanner to a PC?

The 2755-NCR1, an 8 foot coiled RS-232 DCE cable with a female 25-pin connector; a 9-pin port may need an adapter. p. 16, 89

What is the default baud rate of the 2755-G3-D?

9600 baud. It can be set from 300 to 19200 baud by scanning a label. p. 29, 44

How do I reset the 2755 RS-232 scanner to factory defaults?

Scan label ZA; the scanner answers with a bi-level tone. p. 34

Why does the scanner ignore serial commands from the host?

In standby power mode, send a space first to wake it, then wait 150 to 200 milliseconds before the command. p. 82

What power supply does the 2755-G3-D use?

The external 2755-PW1 power supply, which plugs into the 25-pin connector of the interface cable. p. 28

Contents

Chapters and sections

Each line opens the PDF at its page.

  1. Front Cover1
  2. Important User Information2
  3. 1 - Using this Manual8
    1. Chapter Objectives8
    2. Contents of Package8
    3. Intended Audience8
    4. Overview of Manual9
    5. Warning and Caution Symbols10
    6. Related Publications10
  4. 2 - Overview of Scanner11
    1. Chapter Objectives11
    2. Function of Scanner11
    3. Operating Modes12
    4. Setup Parameters13
    5. Serial Commands14
    6. Ordering a Scanner15
    7. Scanner Accessories16
  5. 3 - Using the Scanner17
    1. Chapter Objectives17
    2. Physical Description17
    3. LED Indicators18
    4. Safety Labels19
    5. Scanning Ranges20
    6. Operating Scanner22
    7. Beep23
    8. Operating Tips23
    9. Troubleshooting24
  6. 4 - Setup Instructions25
    1. Chapter Objectives25
    2. Connecting Scanner to Host25
    3. Scanner Configuration Guidelines29
    4. Scanner Default Settings31
    5. Resetting Factory Defaults34
  7. 5 - General Setup Parameters35
    1. Chapter Objectives35
    2. System Status35
    3. Power Consumption37
    4. Beeper Operation38
    5. Capture Count39
51 more lines, from page 40 on
  1. Spotter Beam40
    1. Autosense Mode41
    2. External Trigger Operation42
  2. 6 - Serial Communication Parameters43
    1. Chapter Objectives43
    2. Baud Rate44
    3. Serial Data Transmission Parameters45
    4. Protocol49
    5. Intercharacter Delay52
    6. Serial Transmit Buffer53
  3. 7 - Message Format Parameters54
    1. Chapter Objectives54
    2. Message Format54
    3. Prefix55
    4. Suffix56
    5. Scanner Identifier57
    6. Code Identifier58
    7. Preamble or Postamble59
    8. Preamble60
    9. Postamble60
    10. No Read Message63
  4. 8 - Symbologies64
    1. Chapter Objectives64
    2. Label Lengths64
    3. Code 3965
    4. UPC (A and E)68
    5. EAN/JAN71
    6. Interleaved 2 of 573
    7. Standard 2 of 575
    8. Code 12876
    9. Codabar77
  5. 9 - Serial Commands79
    1. Chapter Objectives79
    2. Serial Command Format79
    3. Manual Scanning Interaction80
    4. ACK/NAK Protocol81
    5. Power Standby and Serial Commands82
    6. Communication Parameter Changes82
  6. 10 - Specifications83
    1. Hand-Held Scanners (Cat.No.2755-G3-D, 2755-G6-D)83
  7. A - Bar Code Text Symbols85
  8. B - Digit Selection Symbols86
  9. C - Autosense Mode87
  10. D - Interface Cable Pinouts89
  11. E - Maintenance91
    1. Cleaning Window91
    2. Inspecting Cables91
  12. F - Scanner Commands92
  13. Glossary96
  14. Index100
  15. Back Cover104

From the PDF’s own bookmarks.

The whole text · 16 parts

Read the manual here as text

Its text as extracted from the PDF, unedited, in parts; each page opens the PDF at that page.

  1. Pages 1 to 71-7
  2. 1 - Using this Manual8-10
  3. 2 - Overview of Scanner11-16
  4. 3 - Using the Scanner17-24
  5. 4 - Setup Instructions25-34
  6. 5 - General Setup Parameters35-42
  7. 6 - Serial Communication Parameters43-53
  8. 7 - Message Format Parameters54-63
  9. 8 - Symbologies64-78
  10. 9 - Serial Commands79-82
  11. Pages 83 to 8583-85
  12. Pages 86 to 8886-88
  13. Pages 89 to 9189-91
  14. F - Scanner Commands92-95
  15. Glossary96-99
  16. Pages 100 to 104100-104

The file

Revision and size

RevisionCatalog Number 2755-NU002 Series A, 1992
PublisherAllen-Bradley Company, Inc.
Pages104
PDF662 KB
TextText from the PDF itself; pages 62 and 86 are scans, read by OCR, which may hold reading errors.

The first pages · 3 of 104

Look before you download

Each page opens the PDF at that page.

Page 1
Page 1of 104
Page 2
Page 2of 104
Page 3
Page 3of 104