The text of a manual · part 5 of 16
Bulletin 2755 Hand-Held Scanner with RS-232 Option User Manual: 4 - Setup Instructions
Pages 25 to 34 of 104, from Bulletin 2755 Hand-Held Scanner with RS-232 Option User Manual
The original document is the PDF (662 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Allen-Bradley 2755-G3
Page 25
Chapter
4
A–B
Setup Instructions Chapter Objectives
This chapter provides setup instructions including:
Connecting Scanner to Host
Before configuring parameters of the scanner, you must connect the scanner to the host device using the appropriate interface cable and power supply. Figure 4.1 shows the connections.
• Connecting Scanner to Host • Scanner Configuration Guidelines • Scanner Default Settings • Resetting Factory Defaults
Figure 4.1 System Connections Power Supply Catalog No. 2755-PW1 AC Power Source
Power Supply Receptacle
Host Device
Scanner Cat. No. 2755-G3-D or 2755-G6-D
RS-232 Serial Port D-Type Connector
Cat. No. 2755-NCR1 or -NCR2
4–1
Page 26
Chapter 4 Setup Instructions
Installing Interface Cable The interface cable has a modular plug (resembling a telephone connector) on one end and a 25 pin D-Type connector on the other end. The available interface cables are listed in Table 2.A. CAUTION:
!
Do not connect scanner to host until host device is turned off. Failure to do this could result in damage to the scanner.
To install the interface cable: 1. Turn power to host computer OFF. 2. Insert the modular plug into the opening at the bottom of the scanner’s handle (see Figure 4.2). The modular plug is keyed to insure proper insertion. Press firmly until the plug clicks into place. Figure 4.2 Installing Interface Cable
3. Plug the 25 pin D-Type connector into the RS-232 receiving port of the host device. Note: You may need an adapter if your computer has a 9-pin port. 4–2
Page 27
Chapter 4 Setup Instructions
Removing Interface Cable At some point you may have to replace the interface cable with another cable. To remove the interface cable, follow these steps. CAUTION:
!
Do not remove the interface cable until host device is turned off. Failure to do this could result in damage to the scanner.
1. Turn power to host device off. 2. Disconnect power supply from AC power source. 3. Disconnect scanner from host device. 4. Insert a straightened paper clip into the cable release hole as shown in Figure 4.3. 5. Press down firmly on the paper clip to release the retainer and gently pull the connector out of the scanner. Figure 4.3 Removing Interface Cable
Cable Release Hole
4–3
Page 28
Chapter 4 Setup Instructions
Installing Power Supply The external power supply (Catalog No. 2755-PW1) provides power to the scanner. One end connects to a standard AC receptacle supplying the appropriate voltage level. The other end plugs into the power receptacle of the 25 pin D-Type connector. CAUTION:
!
The Catalog No. 2755-PW1 Power Supply has the following polarity: +5 V + Ground If using another power supply, the polarity must be the same.
To install the power supply: 1. Power to the host device must be turned off.
CAUTION:
!
Do not connect power supply until the host device is turned off. Failure to follow this caution could result in damage to the scanner or host device.
2. Plug the circular connector into the power supply receptacle of the 25-pin connector. 3. Plug the power supply into a standard AC power source. 4. Review all connections. At this point all components of the system should be connected. Power on the host device. 5. Aim the scanner down at the work surface and press the trigger. You should see the red beam and the SCANNING indicator on the back of the unit should be on. Before configuring the scanner, review the next two sections of this chapter. 4–4
Page 29
Chapter 4 Setup Instructions
Scanner Configuration Guidelines
Configuration is the process of enabling or disabling scanner operating parameters. The host system and the types of bar codes that will be encountered will determine which parameters should be enabled or disabled. Follow three basic steps when selecting parameters: 1. Review the rest of this manual to familiarize yourself with each group of scanner parameters. 2. Review the requirements of your host system and application. This will enable you to determine if the factory defaults must be changed. 3. Enable or disable the relevant parameters by scanning the bar codes in Chapters 5 through 8. The section that follows describes this process. All configuration bar code labels in this manual are Code 128, Character Set B. Scanning Menu Labels The scanner does not have a distinct configuration mode. Instead, it automatically recognizes and reacts to labels you scan. You do not scan a label to enter or exit configuration mode. Most parameters are set by scanning one label. For example, assume that to be compatible with your host system, the scanner’s baud rate setting must be changed from its default value of 9600 to 2400 baud. To make this change, locate the baud rate bar code menu in Chapter 5 and scan the label to the left of 2400 Baud. The correct label is shown below.
DD
2400 Baud
A successful scan is indicated by two short-high beeps. An unsuccessful scan produces no beeps and requires you to rescan the bar code. Most parameters are modified in this way. When you are finished with modifications you can resume normal bar code scanning. 4–5
Page 30
Chapter 4 Setup Instructions
Note: When enabling or disabling a parameter, be sure the scanner beam illuminates only one symbol at a time. The layout of this manual minimizes the accidental scanning of multiple labels. Some parameters require that you scan multiple labels to modify a setting. An example is the Intercharacter Delay parameter. To set the intercharacter delay to 5 milliseconds (msec): 1. Scan the Intercharacter Delay (GB) label and listen for one short beep.
GB
+ Intercharacter Delay=xx msec
The dotted boxes to the right of the label indicate that you must scan two additional labels; one for the digit 0 and the second for the digit 5. 2. After the beep, scan the bar code beside 0 in Appendix B, and listen for one short-high beep. 3. Scan the bar code beside 5 in Appendix B and listen for two short beeps. The two beeps indicate that you scanned the last parameter argument. If you scan the Intercharacter Delay (GB) label and then scan a normal data label (instead of 0 and 5), a normal tone is emitted in response to the data label, and the programming command is ignored. No exit code is required to resume normal operations.
4–6
Page 31
Chapter 4 Setup Instructions
Scanner Default Settings
Table 4.A lists the factory default settings for each group of scanner parameters. Table 4.A Scanner Default Settings
Parameter Power Consumption Beeper Operation
Capture Count External Trigger
Spotter Beam Autosense Mode
Parameter Prefix Suffix Scanner Identifier Code Identifier Preamble Postamble
General Scanner Setup Options Default Enable Continuous Full Power Enable Standby Enable Standby Beeper Off Beeper On; Volume Loud Beeper On; Volume Low Beeper On; Volume Medium Beeper On; Volume Loud 1 or 2 1 Disable Disable External Trigger (+) External Trigger (–) Enable or Disable Enable or Disable
Message Format Options None, STX, or SOH None, ETX, CR, LF, HT, or CR and LF Disable or a number (01- 99) Disable or Enable None or 1-4 characters None or 1-4 characters
Disable Disable
Default None CR and LF Disable Disable None None
4–7
Page 32
Chapter 4 Setup Instructions
Table 4.A (continued) Scanner Default Settings Serial Communication Parameters Baud Rate Serial Data Transmission (Start Bit, Data Bits, Stop Bits, Parity)
Intercharacter Delay Protocol Serial Transmit Buffer
Code Code 39
Options 300, 600, 1200, 2400, 4800, 9600, 19200 7 Data Bits/1Stop Bit/ Odd Parity Even Parity Mark Parity Space Parity 7 Data Bits/2 Stop Bit/Odd Parity Even Parity Mark Parity Space Parity 8 Data Bits/1Stop Bit/ Odd Parity Even Parity Mark Parity Space Parity No Parity 8 Data Bits/2Stop Bit/ No Parity User Defined Delay (in msec) or No Intercharacter Delay XON/XOFF, CTS, RTS or None Full Buffering, No Buffering, One Label Buffering
Symbologies Options Disable Code 39 Enable Standard Code 39 Enable Full ASCII Code 39 Enable or Disable Modulo 43 Check Character Enable or Disable Transmission of Start/Stop Characters Minimum Label Length Maximum Label Length
4–8
Default 9600 7 Data Bits/1Stop Bit/ Space Parity
No Intercharacter Delay None Full Buffering
Default Enable Standard Code 39 Disable Disable 1 32
Page 33
Chapter 4 Setup Instructions
Table 4.A (continued) Scanner Default Settings
Code UPC (A and E)
EAN/JAN (8 or 13 digit)
Interleaved 2 of 5
Standard 2 of 5
Code 128
Codabar
Symbologies Options Disable UPC (A and E) Enable with 2 or 5 Digit Supplements Enable without 2 or 5 Digit Supplements
Default Enable without 2 or 5 Digit Supplements
Enable or Disable Expanded UPC-E Enable or Disable Transmission of Number System Digit Enable or Disable Transmission of Check Digit Enable/Disable UPC to EAN Translation Disable EAN/JAN (8 or 13 digit) Enable with 2 or 5 Digit Supplements Enable without 2 or 5 Digit Supplements
Disable Enable
Enable or Disable Transmission Number System Digit Enable or Disable Transmission of Check Digit Disable Interleaved 2 of 5 Enable without Check Digit Enable with Check Digit
Enable
Minimum Label Length Maximum Label Length Enable or Disable Standard Code 2 of 5 Minimum Label Length Maximum Label Length Enable or Disable Code 128 Minimum Label Length Maximum Label Length Enable or Disable Codabar Enable or Disable Transmission Start/Stop Characters Minimum Label Length Maximum Label Length
2 32 Disable 4 32 Enable 1 32 Disable Disable
Enable Disable Disable
Enable Disable
1 32
4–9
Page 34
Chapter 4 Setup Instructions
Resetting Factory Defaults
To reset the scanner to the factory default settings, scan label ZA.
ZA
Reset to Factory Defaults
Note: Scanning this label produces a bi-level tone.
4–10