Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 16

Bulletin 2755 Hand-Held Scanner with RS-232 Option User Manual: 5 - General Setup Parameters

Pages 35 to 42 of 104, from Bulletin 2755 Hand-Held Scanner with RS-232 Option User Manual

The original document is the PDF (662 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Allen-Bradley 2755-G3

Page 35

Chapter

5

A–B

General Setup Parameters Chapter Objectives

This chapter describes parameters specific to the operation of the scanner including:

• System Status • Power Consumption • Beeper Operation • Capture Count • Spotter Beam • Autosense Mode • External Trigger Operation To set specific operating parameters, scan the appropriate bar code labels in each section. Note: Throughout this chapter, default settings for parameters are flagged by an asterisk (*).

System Status

The labels in this section allow you to examine the configuration of your system. To send a list of currently programmed parameters to the display device, scan option ZB. A sample display is shown on the top of the next page. Note: Scanning ZB may interfere with your terminal software, depending on your application.

ZB

Display Configuration

5–1

Page 36

Chapter 5 General Setup Parameters

Display Configuration Example (ZB Command) Power Standby Data Bits 8 Char Delay 00 Scanner ID None Preamble None Code ID Char No Serial Buffr Full

Parameter 39 *Armed Yes ASCII No *Addendum – Xmit S/S No Check Ch No Send Sys # – Send Ck Ch – UPCE Expand – Limits 01–32

Model 5312 Beeper Loud Parity None Protocol Off Prefix Off Postamble None Labels Unbuffred Display Duplex Half

UPC

Symbology EAN I 2/5

Yes – No – – Yes Yes No –

No No – – No – – – – No Yes – Yes – – – – 02–32

S 2/5

128

No Yes – – – – – – – – – – – – – – 04–32 01–32

Version 2.51 Baud Rate 9600 Stop Bits 1 RTS Rcv Rdy+ Suffix CR/LF * Redundant Scan No Label Delay 00 Auto Label Bfr Off

Codabr No – – No – – – – 01–32

* Redundant Scan=Capture Count, Armed=Enabled, Addendum=Supplements Shaded parameters are not supported in this product.

Scan option ZC to send the program version number followed by carriage return-line feed (CR-LF) to the display device. The version number is sent in the form ##.## (1.00, for example).

ZC

Transmit Version Number

Scan option @C to send an identification code which verifies the specific program type of the scanner to the display device.

@C

Transmit Program ID

Note: Options ZC and @C are used for troubleshooting to identify the scanner. 5–2

Page 37

Chapter 5 General Setup Parameters

Power Consumption

You can select one of two power consumption modes for the scanner. Option @A supplies full power to the scanner at all times. Option @B allows the scanner to revert to standby mode after a successful read. This mode is a power conservation feature whereby the scanner uses extremely low power (microwatts). To supply full power to the scanner at all times, scan label @A.

@A

Enable Continuous Full Power

Note: The scanner automatically uses full power when configured to operate in Autosense mode. To allow the scanner to revert to standby mode after a successful read, scan label @B.

@B

Enable Standby Power *

5–3

Page 38

Chapter 5 General Setup Parameters

Beeper Operation

5–4

To disable or set the volume of the beeper, scan the appropriate option below.

AA

Beeper Off

AB

Beeper On; Volume Low

AC

Beeper On; Volume Medium

AD

Beeper On; Volume Loud *

Page 39

Chapter 5 General Setup Parameters

Capture Count

Capture Count determines the number of successful, identical decodes that must occur for a valid read. You can use the capture count to enhance the security of the bar code reader. Option BC sets the capture count to 1 which requires one successful decode.

BC

Capture Count = 1 *

Scan option BD to set the capture count to 2. Two identical decodes must occur for a valid read.

BD

Capture Count = 2

Because the laser scans a label many times a second, you will notice little or no change in the speed of the decode.

5–5

Page 40

Chapter 5 General Setup Parameters

Spotter Beam

You can enable the scanner to use a spotter beam which helps when aiming the scanner. Each time the scanner is triggered it generates a bright laser spot for a fixed duration, after which the scanner beam is activated. The spotter beam is recommended for long range applications. Scanning label NP disables the spotter beam. Hold the trigger for two seconds after scanning.

Disable Spotter Beam *

NP

To enable the spotter beam, scan label NQ, then scan a digit from 0 – 9 (Appendix B), holding the trigger for two seconds after scanning the digit. Each digit enables the spotter beam for a specified duration as shown in the table below. For example, to enable the spotter beam for 200 milliseconds, scan the NQ label, then scan code 3 in Appendix B. NQ

+ Enable Spotter Beam=xx msec

This Digit 0 1 2 3 4 5 6 7 8 9

Enables Spotter Beam for:

Note: Spotter beam and Autosense mode are mutually exclusive parameters. Only one of these parameters can be enabled at a time. 5–6

Page 41

Chapter 5 General Setup Parameters

Autosense Mode

In Autosense mode, the scanner has an internal object sensor allowing you to operate the scanner in an optional Autostand (Catalog No. 2755-NS2) for hands-free operation. When the scanner is placed in the Autostand it becomes immediately active for reading any bar code label presented to it. The scanner is triggered when a bar code label breaks the scan beam path between the reflective label on the stand and the scanner. To activate Autosense mode, scan the Enable Autosense (NO) label. You must hold the trigger down for two seconds after scanning the label.

NO

Enable Autosense Mode

The scanner will respond by emitting a continuous, low level, red beam of light. Note: The scanner is automatically configured to use full power (not standby power) in Autosense mode. For details on how to set up the scanner to operate in the optional Autostand, see Appendix C. To deactivate Autosense mode, scan the Disable Autosense symbol (NN). You must hold the trigger down for two seconds after scanning the label.

NN

Disable Autosense Mode *

Note: Spotter Beam and Autosense Mode are mutually exclusive parameters. Only one of these parameters can be enabled at a time.

5–7

Page 42

Chapter 5 General Setup Parameters

External Trigger Operation

External trigger operation enables an external device to control scanning. External trigger is controlled by applying an external trigger signal to the CTS input (refer to Appendix D) with external triggering enabled. When active, this signal causes scanning to begin just as if the scanner’s trigger were pressed. Scanning continues until a label is decoded or the external signal is deactivated. Note: CTS protocol cannot be used when external triggering is enabled. When a decode occurs, the trigger signal must be deactivated for a minimum of 50 milliseconds before another scan can be attempted (tying the trigger signal active does not cause continuous scanning and decoding). When External Trigger (+) is scanned, scanning begins when a low level input is applied to the CTS input. Conversely, when External Trigger (–) is scanned, scanning begins when a high level is applied to CTS. When CTS is not connected, it is treated as if a low level is applied.

5–8

HA

Disable External Trigger *

HE

External Trigger (+)

HF

External Trigger (–)